Roozbeh Jafari

Dr. Roozbeh Jafari

Texas A&M University, College Station, United States

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2015 in Multimedia Tools and Applications
Verified
Journal Article
Closed access
PDF file
CCChen Chen
Chen Chen
RJRoozbeh Jafari
Roozbeh Jafari
NKNasser Kehtarnavaz
Nasser Kehtarnavaz

20 June 2022 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
Dmitry KireevDmitry Kireev
Dmitry Kireev
KSKaan Sel
Kaan Sel
BIBassem Ibrahim
Bassem Ibrahim
NKNeelotpala Kumar
Neelotpala Kumar
AAAli Akbari
Ali Akbari
DADeji Akinwande
Deji Akinwande

1 October 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
KSKaan Sel
Kaan Sel
DODeen Osman
Deen Osman
FZFatemeh Zare
Fatemeh Zare
SSSina Masoumi Shahrbabak
Sina Masoumi Shahrbabak
LBLaura Brattain
Laura Brattain
RJRoozbeh Jafari
Roozbeh Jafari
The past several decades have seen rapid advances in diagnosis and treatment of cardiovascular diseases and stroke, enabled by technological breakthroughs in imaging, genomics, and physiological monitoring, coupled with therapeutic interventions. We now face the challenge of how to (1) rapidly process large, complex multimodal and multiscale medical measurements; (2) map all available data streams to the trajectories of disease states over the patient's lifetime; and (3) apply this information for optimal clinical interventions and outcomes. Here we review new advances that may address these challenges using digital twin technology to fulfill the promise of personalized cardiovascular medical practice. Rooted in engineering mechanics and manufacturing, the digital twin is a virtual representation engineered to model and simulate its physical counterpart. Recent breakthroughs in scientific computation, artificial intelligence, and sensor technology have enabled rapid bidirectional interactions between the virtual‐physical counterparts with measurements of the physical twin that inform and improve its virtual twin, which in turn provide updated virtual projections of disease trajectories and anticipated clinical outcomes. Verification, validation, and uncertainty quantification builds confidence and trust by clinicians and patients in the digital twin and establishes boundaries for the use of simulations in cardiovascular medicine. Mechanistic physiological models form the fundamental building blocks of the personalized digital twin that continuously forecast optimal management of cardiovascular health using individualized data streams. We present exemplars from the existing body of literature pertaining to mechanistic model development for cardiovascular dynamics and summarize existing technical challenges and opportunities pertaining to the foundation of a digital twin.

17 August 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
THToan Huu Huynh
Toan Huu Huynh
RJRoozbeh Jafari
Roozbeh Jafari
Wan-Young ChungWan-Young Chung
Wan-Young Chung
To demonstrate the feasibility of leveraging impedance plethysmography (IPG) for detection of pulse transit time (PTT) and estimation of blood pressure (BP). Methods: We first established the relationship between BP, PTT, and arterial impedance (i.e., the output of IPG). The IPG sensor was placed on the wrist while the photoplethysmography (PPG) sensor was attached to the index finger to measure the PTT. With a cuff-based BP monitoring system placed on the upper arm as a reference, our proposed methodology was evaluated on 15 young, healthy human subjects and compared to several conventional PTT models to assess the efficacy. Results: The proposed model correlated with BP fairly well with group average correlation coefficients of 0.88 ± 0.07 for systolic BP (SBP) and 0.88 ± 0.06 for diastolic BP (DBP). In comparison with the other PTT methods, PTT-IPG-based BP estimation achieved a lower root-mean-squared-error (RMSE) of 8.47 ± 0.91 mmHg and 5.02 ± 0.73 mmHg for SBP and DBP, respectively. Conclusion: We conclude that the measurement of arterial impedance via IPG methods is an adequate indicator to estimate BP. The proposed method appears to offer superiority compared to the conventional PTT estimation approaches. Significance: Using impedance magnitude to estimate PTT offers promise to realize wearable and cuffless BP devices.

17 January 2025 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
KSKaan Sel
Kaan Sel
AHAndrea Hawkins-Daarud
Andrea Hawkins-Daarud
ACAnirban Chaudhuri
Anirban Chaudhuri
DODeen Osman
Deen Osman
ABAhmad Bahai
Ahmad Bahai
RJRoozbeh Jafari
Roozbeh Jafari
Digital twins in precision medicine provide tailored health recommendations by simulating patient-specific trajectories and interventions. We examine the critical role of Verification, Validation, and Uncertainty Quantification (VVUQ) for digital twins in ensuring safety and efficacy, with examples in cardiology and oncology. We highlight challenges and opportunities for developing personalized trial methodologies, validation metrics, and standardizing VVUQ processes. VVUQ frameworks are essential for integrating digital twins into clinical practice.

3 November 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
HJHongwoo Jang
Hongwoo Jang
KSKaan Sel
Kaan Sel
EKEunbin Kim
Eunbin Kim
SKSangjun Kim
Sangjun Kim
XYXiangxing Yang
Xiangxing Yang
NLNanshu Lu
Nanshu Lu
Electrodermal activity (EDA) is a popular index of mental stress. State-of-the-art EDA sensors suffer from obstructiveness on the palm or low signal fidelity off the palm. Our previous invention of sub-micron-thin imperceptible graphene e-tattoos (GET) is ideal for unobstructive EDA sensing on the palm. However, robust electrical connection between ultrathin devices and rigid circuit boards is a long missing component for ambulatory use. To minimize the well-known strain concentration at their interfaces, we propose heterogeneous serpentine ribbons (HSPR), which refer to a GET serpentine partially overlapping with a gold serpentine without added adhesive. A fifty-fold strain reduction in HSPR vs. heterogeneous straight ribbons (HSTR) has been discovered and understood. The combination of HSPR and a soft interlayer between the GET and an EDA wristband enabled ambulatory EDA monitoring on the palm in free-living conditions. A newly developed EDA event selection policy leveraging unbiased selection of phasic events validated our GET EDA sensor against gold standards.