This paper presents a comprehensive modeling and experimental verification of active piezoresistive atomic force microscopy (AFM) cantilevers, which are the technology enabling high-resolution and high-speed surface measurements. The mechanical structure of the cantilevers integrating Wheatstone piezoresistive was modified with the use of focused ion beam (FIB) technology in order to increase the deflection sensitivity with minimal influence on structure stiffness and its resonance frequency. The FIB procedure was conducted based on the finite element modeling (FEM) methods. In order to monitor the increase in deflection sensitivity, the active piezoresistive cantilever was deflected using an actuator integrated within, which ensures reliable and precise assessment of the sensor properties. The proposed procedure led to a 2.5 increase in the deflection sensitivity, which was compared with the results of the calibration routine and analytical calculations.
In this paper, a novel fabrication technology of atomic force microscopy (AFM) probes integrating cantilever tips with an NV-rich diamond particle is presented. Nanomanipulation techniques combined with the focused electron beam-induced deposition (FEBID) procedure were applied to position the NV-rich diamond particle on an AFM cantilever tip. Ultrasonic treatment of nanodiamond suspension was applied to reduce the size of diamond particles for proper geometry and symmetry. The fabricated AFM probes were tested utilizing measurements of the electrical resistance at highly oriented pyrolytic graphite (HOPG) and compared with a standard AFM cantilever performance. The results showed novel perspectives arising from combining the functionalities of a scanning AFM with optically detected magnetic resonance (ODMR). In particular, it offers enhanced magnetometric sensitivity and the nanometric resolution.
Atomic force microscopy (AFM) belongs to the high resolution and high sensitivity surface imaging technologies. In this method force interactions between the tip and the surface are observed to characterize sample properties. In the so-called contact AFM (C AFM) mode the tip is brought into continuous contact with the sample. Significant progress in the AFM technology can be obtained, when the so-called active cantilever technology is implemented in the surface measurements. The built-in deflection actuator enables very precise excitation of the cantilever. Moreover, as the mass of the beam is very small the static beam displacement can be controlled in the wide frequency range. In the experiments, which we describe in this article, we applied the so called active electromagnetic cantilevers. They integrate a conductive loop which, when immersed in the magnetic field and biased with electric current, acts as an electromagnetic deflection actuator. The induced and precisely estimated Lorentz force, which is a function of bias current, cantilever geometry and magnetic field makes the cantilever deflect. Moreover, the probe stiffness can be calibrated with lower uncertainty as in the case of standard thermomechanical analysis. NZ AFM technology required application of a novel control algorithm, called PredPID, in which the cantilever bending caused by a proportional-integral-derivative (PID) block maintaining the constant load force was predicted.
8 January 2020 in Metrology and Measurement Systems
Platinum-carbon (PtC) composite nanowires were fabricated using focused electron beam induced deposition and postprocessed, and their performance as a nanoscale resistive thermal device (RTD) was evaluated. Nanowires were free-standing and deposited on a dedicated substrate to eliminate the influence of the substrate itself and of the halo effect on the results. The PtC free-standing nanowires were postprocessed to lower their electrical resistance using electron beam irradiation and thermal annealing using Joule heat both separately and combined. Postprocessed PtC free-standing nanowires were characterized to evaluate their noise figure (NF) and thermal coefficients at the temperature range from 30 K to 80 °C. The thermal sensitivity of RTD was lowered with the reduced resistance but simultaneously the NF improved, especially with electron-beam irradiation. The temperature measurement resolution achievable with the PtC free-standing nanowires was 0.1 K in 1 kHz bandwidth.