Teodor Gotszalk

Prof. Teodor Gotszalk


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Nanotechnology
Verified
Journal Article
Closed access
PDF file
MTMagdalena Tamulewicz-Szwajkowska
Magdalena Tamulewicz-Szwajkowska
JKJoanna Kutrowska-Girzycka
Joanna Kutrowska-Girzycka
KGKrzysztof Radosław Gajewski
Krzysztof Radosław Gajewski
JSJarosław Serafińczuk
Jarosław Serafińczuk
ASAndrzej Sierakowski
Andrzej Sierakowski
TGTeodor Gotszalk
Teodor Gotszalk
We have examined the influence of flake-substrate effects that affect one and few layers of MoS 2 in terms of their electrical and optical properties. In the measurements, we used SiO 2 /Si substrates with etched cavities and aluminum electrodes. Suspended areas are easily identifiable both on images depicting the topography and on the surface potential maps measured with the Kelvin probe force microscopy. Compared to the SiO 2 /Si supported material, surface potential decrease is observable at the membrane. The surface potential value of the flakes located on the electrodes is the lowest. PL measurements prove that single MoS 2 monolayer was obtained. Suspended regions are also correlated with maps obtained as a result of Raman spectroscopy.

7 April 2020 in Viruses
Verified
Journal Article
Open access
PDF file
GGGrzegorz Guła
Grzegorz Guła
PSPaulina Szymanowska
Paulina Szymanowska
TPTomasz Piasecki
Tomasz Piasecki
SGSylwia Góras
Sylwia Góras
TGTeodor Gotszalk
Teodor Gotszalk
ZDZuzanna Drulis-Kawa
Zuzanna Drulis-Kawa
Bacterial biofilm prevention and eradication are common treatment problems, hence there is a need for advanced and precise experimental methods for its monitoring. Bacterial resistance to antibiotics has resulted in an interest in using a natural bacterial enemy—bacteriophages. In this study, we present the application of quartz tuning forks (QTF) as impedance sensors to determine in real-time the direct changes in Pseudomonas aeruginosa PAO1 biofilm growth dynamics during Pseudomonas phage LUZ 19 treatment at different multiplicities of infection (MOI). The impedance of the electric equivalent circuit (EEC) allowed us to measure the series resistance (Rs) corresponding to the growth-medium resistance (planktonic culture changes) and the conductance (G) corresponding to the level of QTF sensor surface coverage by bacterial cells and the extracellular polymer structure (EPS) matrix. It was shown that phage impacts on sessile cells (G dynamics) was very similar in the 10-day biofilm development regardless of applied MOI (0.1, 1 or 10). The application of phages at an early stage (at the sixth h) and on three-day biofilm caused a significant slowdown in biofilm dynamics, whereas the two-day biofilm turned out to be insensitive to phage infection. We observed an inhibitory effect of phage infection on the planktonic culture (Rs dynamics) regardless of the MOI applied and the time point of infection. Moreover, the Rs parameter made it possible to detect PAO1 population regrowth at the latest time points of incubation. The number of phage-insensitive forms reached the level of untreated culture at around the sixth day of infection. We conclude that the proposed impedance spectroscopy technique can be used to measure the physiological changes in the biofilm matrix composition, as well as the condition of planktonic cultures in order to evaluate the activity of anti-biofilm compounds.

16 September 2021 in Advanced Materials Interfaces
Verified
Journal Article
Closed access
PDF file
Mateusz FicekMateusz Ficek
Mateusz Ficek
BDBartlomiej Dec
Bartlomiej Dec
SJSankaran K. J.
Sankaran K. J.
KGKrzysztof Gajewski
Krzysztof Gajewski
PTPiotr Tatarczak
Piotr Tatarczak
RBRobert Bogdanowicz
Robert Bogdanowicz

2 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Paolo Di BarbaPaolo Di Barba
Paolo Di Barba
TGTeodor Gotszalk
Teodor Gotszalk
WMWojciech Majstrzyk
Wojciech Majstrzyk
MMMaria Evelina Mognaschi
Maria Evelina Mognaschi
KOKarolina Orłowska
Karolina Orłowska
ASAndrzej Sierakowski
Andrzej Sierakowski
In this paper we present the numerical and experimental results of a design optimization of electromagnetic cantilevers. In particular, a cost-effective technique of evolutionary computing enabling the simultaneous minimization of multiple criteria is applied. A set of optimal solutions are subsequently fabricated and measured. The designed cantilevers are fabricated in arrays, which makes the comparison and measurements of the sensor properties reliable. The microfabrication process, based on the silicon on insulator (SOI) technology, is proposed in order to minimize parasitic phenomena and enable efficient electromagnetic actuation. Measurements on the fabricated prototypes assessed the proposed methodological approach.

11 February 2020 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
ŁGŁ. Gelczuk
Ł. Gelczuk
MDM. Dąbrowska-Szata
M. Dąbrowska-Szata
VKVl. Kolkovsky
Vl. Kolkovsky
MSMariusz Sochacki
Mariusz Sochacki
JSJan Szmidt
Jan Szmidt
TGTeodor Gotszalk
Teodor Gotszalk
Several deep level defects were observed by conventional deep level transient spectroscopy (DLTS) and high-resolution Laplace DLTS (LDLTS) in n-type 4H-SiC junction barrier Schottky diodes. We have shown that the broad DLTS peak labeled Z1/2 has, in fact, two components, Z1 and Z2, with activation enthalpies for electron emission of 0.63 eV and 0.68 eV, respectively. The reorientation process between these two components was observed. A combination of double-correlated DLTS and LDLTS demonstrated an anomalous reduction of the emission rate and an increase of the activation enthalpy of Z2 with an increase of the reverse bias applied to the diode. The possible explanation of this phenomenon could be correlated with a tensile stress in epitaxial SiC layers. The results observed are discussed in the frame of the model that correlates Z1 and Z2 with carbon vacancies (VC), located at hexagonal (h) and cubic (k) lattice sites, respectively. We also discussed the origin of other traps E0–E5 with particular emphasis on a N-related shallow donor level located at 0.04 eV below the conduction band, which has never been previously reported by DLTS studies.

12 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
PKPiotr Kunicki
Piotr Kunicki
TATihomir Angelov
Tihomir Angelov
TITzvetan Ivanov
Tzvetan Ivanov
TGTeodor Gotszalk
Teodor Gotszalk
IRIvo W. Rangelow
Ivo W. Rangelow
This paper presents a comprehensive modeling and experimental verification of active piezoresistive atomic force microscopy (AFM) cantilevers, which are the technology enabling high-resolution and high-speed surface measurements. The mechanical structure of the cantilevers integrating Wheatstone piezoresistive was modified with the use of focused ion beam (FIB) technology in order to increase the deflection sensitivity with minimal influence on structure stiffness and its resonance frequency. The FIB procedure was conducted based on the finite element modeling (FEM) methods. In order to monitor the increase in deflection sensitivity, the active piezoresistive cantilever was deflected using an actuator integrated within, which ensures reliable and precise assessment of the sensor properties. The proposed procedure led to a 2.5 increase in the deflection sensitivity, which was compared with the results of the calibration routine and analytical calculations.