Patrick Henry Geoghegan

Patrick Henry Geoghegan

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2012 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
PGPatrick Henry Geoghegan
Patrick Henry Geoghegan
NBN. A. Buchmann
N. A. Buchmann
CSC. J. T. Spence
C. J. T. Spence
SMS. Moore
S. Moore
MJMark C Jermy
Mark C Jermy

9 July 2018 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
SYSina G. Yazdi
Sina G. Yazdi
PGPatrick Henry Geoghegan
Patrick Henry Geoghegan
PDPaul D. Docherty
Paul D. Docherty
MJMark Jermy
Mark Jermy
AKAdib Khanafer
Adib Khanafer

3 May 2013 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
PGPatrick Henry Geoghegan
Patrick Henry Geoghegan
NBN. A. Buchmann
N. A. Buchmann
JSJ. Soria
J. Soria
MJM. C. Jermy
M. C. Jermy

8 April 2016 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
SHS. C. Van Hove
S. C. Van Hove
JSJ. Storey
J. Storey
CAC. Adams
C. Adams
KDK. Dey
K. Dey
PGPatrick Henry Geoghegan
Patrick Henry Geoghegan
John Edward CaterJohn Edward Cater
John Edward Cater

11 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SYSina G. Yazdi
Sina G. Yazdi
LHLarissa Huetter
Larissa Huetter
PDPaul D. Docherty
Paul D. Docherty
PWPetra N. Williamson
Petra N. Williamson
DCDon Clucas
Don Clucas
PGPatrick Henry Geoghegan
Patrick Henry Geoghegan
Cardiovascular diseases (CVDs) are one of the leading causes of death globally. In-vitro measurement of blood flow in compliant arterial phantoms can provide better insight into haemodynamic states and therapeutic procedures. However, current fabrication techniques are not capable of producing thin-walled compliant phantoms of complex shapes. This study presents a new approach for the fabrication of compliant phantoms suitable for optical measurement. Two 1.5× scaled models of the ascending aorta, including the brachiocephalic artery (BCA), were fabricated from silicone elastomer Sylgard-184. The initial phantom used the existing state of the art lost core manufacturing technique with simple end supports, an acrylonitrile butadiene styrene (ABS) additive manufactured male mould and Ebalta-milled female mould. The second phantom was produced with the same method but used more rigid end supports and ABS male and female moulds. The wall thickness consistency and quality of resulting stereoscopic particle image velocimetry (SPIV) were used to verify the fidelity of the phantom for optical measurement and investigation of physiological flow fields. However, the initial phantom had a rough surface that obscured SPIV analysis and had a variable wall thickness (range = 0.815 mm). The second phantom provided clear particle images and had a less variable wall thickness (range = 0.317 mm). The manufacturing method developed is suitable for fast and cost-effective fabrication of different compliant arterial phantom geometries.

21 July 2016 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
PDF file
PGPatrick Henry Geoghegan
Patrick Henry Geoghegan
MJMark C Jermy
Mark C Jermy
David S. NobesDavid S. Nobes
David S. Nobes