This paper reports on an experimental investigation to determine the structure and mean flow quantities of round zero-net-mass-flux (ZNMF) jets. These jets are generated by a piston oscillating in a cavity behind a circular orifice. Several different flow patterns were observed with dye flow visualization and a parameter map of these was generated. Cross-correlation digital particle image velocimetry was used to measure instantaneous two-dimensional in-plane velocity fields in a plane containing the orifice axis. These velocity fields are used to investigate the existence of a self-preserving velocity profile in the far field of the ZNMF jet. The mean flow quantities and turbulent statistics of the ZNMF jets were compared with measurements for ‘equivalent’ continuous jets in the same apparatus. Phase-averaged velocity measurements were obtained in the near field of the ZNMF jets and were used to determine the radial entrainment. The out-of-plane vorticity fields were also investigated to gain an understanding of the mechanisms responsible for the difference in spreading rate of ZNMF jets compared to conventional continuous jets. A conceptual model of the ZNMF jet structure in the near field for Strouhal numbers much less than one is proposed that explains the observed behaviour of these ZNMF jets.
Stent induced hemodynamic changes in the coronary arteries are associated with higher risk of adverse clinical outcome. The purpose of this study was to evaluate the impact of stent design on wall shear stress (WSS), time average WSS, and WSS gradient (WSSG), in idealized stent geometries using computational fluid dynamics. Strut spacing, thickness, luminal protrusion, and malapposition were systematically investigated and a comparison made between two commercially available stents (Omega and Biomatrix). Narrower strut spacing led to larger areas of adverse low WSS and high WSSG but these effects were mitigated when strut size was reduced, particularly for WSSG. Local hemodynamics worsened with luminal protrusion of the stent and with stent malapposition, adverse high WSS and WSSG were identified around peak flow and throughout the cardiac cycle respectively. For the Biomatrix stent, the adverse effect of thicker struts was mitigated by greater strut spacing, radial cell offset and flow-aligned struts. In conclusion, adverse hemodynamic effects of specific design features (such as strut size and narrow spacing) can be mitigated when combined with other hemodynamically beneficial design features but increased luminal protrusion can worsen the stent’s hemodynamic profile significantly.