Kate Shanks

Dr. Kate Shanks


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2016 in Microscopy and Microanalysis
Verified
Journal Article
Closed access
PDF file
MTMark W. Tate
Mark W. Tate
PPPrafull Purohit
Prafull Purohit
DCDarol Chamberlain
Darol Chamberlain
KNKayla X. Nguyen
Kayla X. Nguyen
RHRobert Hovden
Robert Hovden
SGSol M. Gruner
Sol M. Gruner
We describe a hybrid pixel array detector (electron microscope pixel array detector, or EMPAD) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128×128 pixel detector consists of a 500 µm thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit. The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition system, and preliminary results from experiments with 80–200 keV electron beams.

22 July 2023 in Acta Materialia
Verified
Journal Article
Closed access
JRJie Ren
Jie Ren
MWMargaret Wu
Margaret Wu
CLChenyang Li
Chenyang Li
SGShuai Guan
Shuai Guan
JDJiaqi Dong
Jiaqi Dong
WCWen Chen
Wen Chen

7 August 2014 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
KGKlaus Giewekemeyer
Klaus Giewekemeyer
HPHugh T Philipp
Hugh T Philipp
RWRobin N Wilke
Robin N Wilke
AAAndrew Aquila
Andrew Aquila
MOMarkus Osterhoff
Markus Osterhoff
AMAdrian P Mancuso
Adrian P Mancuso
Coherent (X-ray) diffractive imaging (CDI) is an increasingly popular form of X-ray microscopy, mainly due to its potential to produce high-resolution images and the lack of an objective lens between the sample and its corresponding imaging detector. One challenge, however, is that very high dynamic range diffraction data must be collected to produce both quantitative and high-resolution images. In this work, hard X-ray ptychographic coherent diffractive imaging has been performed at the P10 beamline of the PETRA III synchrotron to demonstrate the potential of a very wide dynamic range imaging X-ray detector (the Mixed-Mode Pixel Array Detector, or MM-PAD). The detector is capable of single photon detection, detecting fluxes exceeding 1 × 1088-keV photons pixel−1s−1, and framing at 1 kHz. A ptychographic reconstruction was performed using a peak focal intensity on the order of 1 × 1010 photons µm−2s−1within an area of approximately 325 nm × 603 nm. This was done without need of a beam stop and with a very modest attenuation, while `still' images of the empty beam far-field intensity were recorded without any attenuation. The treatment of the detector frames and CDI methodology for reconstruction of non-sensitive detector regions, partially also extending the active detector area, are described.

20 March 2019 in IUCrJ
Verified
Journal Article
Open access
PDF file
KGK. Giewekemeyer
K. Giewekemeyer
AAA. Aquila
A. Aquila
NLN.-T. D. Loh
N.-T. D. Loh
YCY. Chushkin
Y. Chushkin
KSKate Shanks
Kate Shanks
AMA. P. Mancuso
A. P. Mancuso
The routine atomic resolution structure determination of single particles is expected to have profound implications for probing structure–function relationships in systems ranging from energy-storage materials to biological molecules. Extremely bright ultrashort-pulse X-ray sources – X-ray free-electron lasers (XFELs) – provide X-rays that can be used to probe ensembles of nearly identical nanoscale particles. When combined with coherent diffractive imaging, these objects can be imaged; however, as the resolution of the images approaches the atomic scale, the measured data are increasingly difficult to obtain and, during an X-ray pulse, the number of photons incident on the 2D detector is much smaller than the number of pixels. This latter concern, the signal `sparsity', materially impedes the application of the method. An experimental analog using a conventional X-ray source is demonstrated and yields signal levels comparable with those expected from single biomolecules illuminated by focused XFEL pulses. The analog experiment provides an invaluable cross check on the fidelity of the reconstructed data that is not available during XFEL experiments. Using these experimental data, it is established that a sparsity of order 1.3 × 10−3 photons per pixel per frame can be overcome, lending vital insight to the solution of the atomic resolution XFEL single-particle imaging problem by experimentally demonstrating 3D coherent diffractive imaging from photon-sparse random projections.

28 January 2016 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
HPHugh T. Philipp
Hugh T. Philipp
MTMark W. Tate
Mark W. Tate
PPPrafull Purohit
Prafull Purohit
KSKate Shanks
Kate Shanks
JWJoel T. Weiss
Joel T. Weiss
SGSol M. Gruner
Sol M. Gruner
A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8–12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10–100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. The characteristics, operation, testing and application of the detector are detailed.

1 December 2016 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
JBJ. Becker
J. Becker
MTM.W. Tate
M.W. Tate
KSKate Shanks
Kate Shanks
HPH.T. Philipp
H.T. Philipp
JWJ.T. Weiss
J.T. Weiss
SGS.M. Gruner
S.M. Gruner
Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we present characterizations of CdTe sensors hybridized with two different charge-integrating readout chips, the Keck PAD and the Mixed-Mode PAD (MM-PAD), both developed previously in our laboratory. The charge-integrating architecture of each of these PADs extends the instantaneous counting rate by many orders of magnitude beyond that obtainable with photon counting architectures. The Keck PAD chip consists of rapid, 8-frame, in-pixel storage elements with framing periods < 150 ns. The second detector, the MM-PAD, has an extended dynamic range by utilizing an in-pixel overflow counter coupled with charge removal circuitry activated at each overflow. This allows the recording of signals from the single-photon level to tens of millions of x-rays/pixel/frame while framing at 1 kHz. Both detector chips consist of a 128 × 128 pixel array with (150 μm)2 pixels.