Prafull Purohit

Prafull Purohit

Instrumentation Division, Brookhaven National Laboratory, Upton, New York, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2018 in Nature
Verified
Journal Article
Closed access
PDF file
YJYi Jiang
Yi Jiang
ZCZhen Chen
Zhen Chen
YHYimo Han
Yimo Han
PDPratiti Deb
Pratiti Deb
HGHui Gao
Hui Gao
DMDavid A. Muller
David A. Muller

11 January 2016 in Microscopy and Microanalysis
Verified
Journal Article
Closed access
PDF file
MTMark W. Tate
Mark W. Tate
PPPrafull Purohit
Prafull Purohit
DCDarol Chamberlain
Darol Chamberlain
KNKayla X. Nguyen
Kayla X. Nguyen
RHRobert Hovden
Robert Hovden
SGSol M. Gruner
Sol M. Gruner
We describe a hybrid pixel array detector (electron microscope pixel array detector, or EMPAD) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128×128 pixel detector consists of a 500 µm thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit. The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition system, and preliminary results from experiments with 80–200 keV electron beams.

1 December 2017 in Journal of the Mechanics and Physics of Solids
Verified
Journal Article
Closed access
KCK. Chatterjee
K. Chatterjee
JKJ.Y.P. Ko
J.Y.P. Ko
JWJ.T. Weiss
J.T. Weiss
HPH.T. Philipp
H.T. Philipp
JBJ. Becker
J. Becker
ABA.J. Beaudoin
A.J. Beaudoin

1 December 2016 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
JBJ. Becker
J. Becker
MTM.W. Tate
M.W. Tate
KSKate Shanks
Kate Shanks
HPH.T. Philipp
H.T. Philipp
JWJ.T. Weiss
J.T. Weiss
SGS.M. Gruner
S.M. Gruner
Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we present characterizations of CdTe sensors hybridized with two different charge-integrating readout chips, the Keck PAD and the Mixed-Mode PAD (MM-PAD), both developed previously in our laboratory. The charge-integrating architecture of each of these PADs extends the instantaneous counting rate by many orders of magnitude beyond that obtainable with photon counting architectures. The Keck PAD chip consists of rapid, 8-frame, in-pixel storage elements with framing periods < 150 ns. The second detector, the MM-PAD, has an extended dynamic range by utilizing an in-pixel overflow counter coupled with charge removal circuitry activated at each overflow. This allows the recording of signals from the single-photon level to tens of millions of x-rays/pixel/frame while framing at 1 kHz. Both detector chips consist of a 128 × 128 pixel array with (150 μm)2 pixels.

8 March 2017 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
JWJoel T. Weiss
Joel T. Weiss
KSKate Shanks
Kate Shanks
HPHugh T. Philipp
Hugh T. Philipp
JBJulian Becker
Julian Becker
DCDarol Chamberlain
Darol Chamberlain
SGSol M. Gruner
Sol M. Gruner
Several charge integrating CMOS pixel front ends utilizing charge removal techniques have been fabricated to extend dynamic range for X-ray diffraction applications at synchrotron sourcesand X-ray free electron lasers (XFELs). The pixels described herein build on the mixed mode pixel array detector (MM-PAD) framework, developed previously by our group to perform high dynamic range imaging. These new pixels boast several orders of magnitude improvement in maximum flux over the MM-PAD, which is capable of measuring a sustained flux in excess of 10 8 X-rays/pixel/s while maintaining sensitivity to smaller signals, down to single X-rays. To extend dynamic range, charge is removed from the integration node of the frontend amplifier without interrupting integration. The number of times this process occurs is recorded by a digital counter in the pixel. The parameter limiting full well is, thereby, shifted from the size of an integration capacitor to the depth of a digital counter. The result is similar to that achieved by counting pixel array detectors, but the integrators presented here are designed to tolerate a sustained flux > 10 11 X-rays/pixel/s. Pixel front-end linearity was evaluated by direct current injection and results are presented. A small-scale readout ASIC utilizing these pixel architectures has been fabricated and the use of these architectures to increase single X-ray pulse dynamic range at XFELs is discussed briefly.

26 May 2023 in Physical Review B
Verified
Journal Article
Closed access
PDF file
KNK. X. Nguyen
K. X. Nguyen
YJY. Jiang
Y. Jiang
MCM. C. Cao
M. C. Cao
PPPrafull Purohit
Prafull Purohit
AYA. K. Yadav
A. K. Yadav
DMD. A. Muller
D. A. Muller
Orbital angular momentum (OAM) and torque transfer play central roles in a wide range of magnetic textures and devices including skyrmions and spin-torque electronics. Analogous topological structures are now also being explored in ferroelectrics, including polarization vortex arrays in ferroelectric/dielectric superlattices. Unlike magnetic toroidal order, electric toroidal order does not couple directly to linear external fields. Instead, we find that the presence of an electric toroidal moment in a ferrorotational phase transfers measurable torque and OAM to a localized electron beam in the ballistic limit. We record these torque transfers from a high-energy electron beam using a momentum-resolved detector. This approach provides a high-sensitivity method to detect polarization fields and their more complex order parameters and topologies. In addition to toroidal order, we also demonstrate high-precision measurements of vorticity and chirality for polar vortexlike phases.