German Gomez

German Gomez

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2014 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
GGGerman Gomez
German Gomez
JPJanusz Pawliszyn
Janusz Pawliszyn

1 September 2015 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
ÉSÉrica A. Souza-Silva
Érica A. Souza-Silva
NRNathaly Reyes-Garcés
Nathaly Reyes-Garcés
GGGerman Gomez
German Gomez
EBEzel Boyacı
Ezel Boyacı
Barbara BojkoBarbara Bojko
Barbara Bojko
JPJanusz Pawliszyn
Janusz Pawliszyn

1 October 2012 in Analytica Chimica Acta
Verified
Journal Article
Closed access
Barbara BojkoBarbara Bojko
Barbara Bojko
ECErasmus Cudjoe
Erasmus Cudjoe
GGGerman Gomez
German Gomez
Krzysztof GorynskiKrzysztof Gorynski
Krzysztof Gorynski
RJRuifen Jiang
Ruifen Jiang
JPJanusz Pawliszyn
Janusz Pawliszyn


29 December 2015 in Analytical Chemistry
Verified
Journal Article
Open access
GGGerman Gomez
German Gomez
NRNathaly Reyes-Garcés
Nathaly Reyes-Garcés
Barbara BojkoBarbara Bojko
Barbara Bojko
JPJanusz Pawliszyn
Janusz Pawliszyn
In recent years, different geometrical configurations of SPME have been directly coupled to mass spectrometry, resulting in benefits such as diminishing matrix effects, improvement of detection limits, and considerable enhancement of analysis throughput. Although SPME fibers have been used for years, their potential for quantitative analysis when directly combined with mass spectrometry has not been explored to its full extent. In this study, we present the direct coupling of biocompatible-SPME (Bio-SPME) fibers to mass spectrometry via nano-ESI emitters as a powerful tool for fast quantitative analysis of target analytes in biofluids. Total sample preparation time does not exceed 2 min and, by selecting an appropriate fiber length and sample vessel, sample volumes ranging between 10 and 1500 μL can be used. Despite the short extraction time of the technique, limits of detection in the sub-nanogram per millilitre with good accuracy (≥ 90 %) and linearity (R2>0.999) were attained for all the studied probes...

26 August 2014 in Chemical Communications
Verified
Journal Article
Open access
PDF file
GGGerman Gomez
German Gomez
JPJanusz Pawliszyn
Janusz Pawliszyn
A new SPME device was developed and applied for quick solventless extraction/enrichment of small molecules from complex matrices. Subsequently, the device was coupled as a transmission mode substrate to DART resulting in limits of detection in the low pg mL−1 level in less than 3 minutes with reproducibility below 5% RSD.