Frederic Colas

Dr. Frederic Colas

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
TQTaoufik Qoria
Taoufik Qoria
FGFrancois Gruson
Francois Gruson
FCFrederic Colas
Frederic Colas
GDGuillaume Denis
Guillaume Denis
TPThibault Prevost
Thibault Prevost
XGXavier Guillaud
Xavier Guillaud
The present paper deals with the post-fault synchronization of a voltage source converter based on the droop control. In case of large disturbances on the grid, the current is limited via current limitation algorithms such as the virtual impedance. During the fault, the power converter internal frequency deviates resulting in a converter angle divergence. Thereby, the system may lose the synchronism after fault clearing and which may lead to instability. Hence, this paper proposes a theoretical approach to explain the dynamic behavior of the grid forming converter subject to a three phase bolted fault. A literal expression of the critical clearing time is defined. Due to the precise analysis of the phenomenon, a simple algorithm can be derived to enhance the transient stability. It is based on adaptive gain included in the droop control. These objectives have been achieved with no external information and without switching from one control to the other. To prove the effectiveness of the developed control, experimental test cases have been performed in different faulted conditions.

5 September 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JFJulian Freytes
Julian Freytes
SASamy Akkari
Samy Akkari
PRPierre Rault
Pierre Rault
MBMohamed Moez Belhaouane
Mohamed Moez Belhaouane
FGFrancois Gruson
Francois Gruson
XGXavier Guillaud
Xavier Guillaud
This article deals with DC voltage dynamics of Multi-Terminal HVDC grids with energy-based controlled Mo\-dular Multilevel Converters (MMC) adopting the commonly used power-voltage droop control technique for power flow dispatch. Special focus is given on the energy management strategies of the MMCs and their ability to influence on the DC voltage dynamics. First, it is shown that decoupling the MMC energy from the DC side by controlling the energy to a fixed value, regardless of the DC voltage level, causes large and undesired DC voltage transient after a sudden power flow change. Second, the Virtual Capacitor Control technique is implemented in order to improve the results, however, its limitations on droop-based MTDC grids are highlighted. Finally, a novel energy management approach is proposed to improve the performance of the later method. These studies are performed with detailed MMC models suitable for the use of linear analysis techniques. The derived MTDC models are validated against time-domain simulations using detailed EMT MMC models with 400 sub-modules per arm.

28 May 2020 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Open access
CLChuanyue Li
Chuanyue Li
JLJun LIANG
Jun LIANG
LCLiana Cipcigan
Liana Cipcigan
WMWenlong Ming
Wenlong Ming
FCFrederic Colas
Frederic Colas
XGXavier Guillaud
Xavier Guillaud
For a grid-connected inverter requiring the ac volt- age magnitude and the active power control, both vector control and power synchronization control can be applied. The stability comparison based on the dq impedance stability analysis between both control are carried out via three factors including the grid impedance, the inner current loop and the virtual impedance. The dq impedances of the inverter based on both control are derived. The determinant of the impedance ratio is used for the stability analysis. The bode plot of the grid impedance and the inverter impedance are present to assist the stability analysis and explain their interactions. It is found that increasing the grid impedance and the cut-off frequency of the current loop stabilize the inverter with the power synchronization control, which is converse to the vector control. Furthermore, the inverter with the power synchronization control may suffer the instabilities when connecting to a strong grid. The virtual inductor and resistor are proposed to enhance the stability for the vector control and the power synchronization control respectively. The simulation validation using Matlab/Simulink is performed.

15 July 2024 in Electric Power Systems Research
Verified
Journal Article
Closed access
CCCarmen Cardozo
Carmen Cardozo
TPThibault Prevost
Thibault Prevost
SHShun-Hsien Huang
Shun-Hsien Huang
JLJingwei Lu
Jingwei Lu
NMNilesh Modi
Nilesh Modi
XGXavier Guillaud
Xavier Guillaud

29 May 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ESEjlal Shahriari
Ejlal Shahriari
FGFrancois Gruson
Francois Gruson
PVPierre Vermeersch
Pierre Vermeersch
PDPhilippe Delarue
Philippe Delarue
FCFrederic Colas
Frederic Colas
XGXavier Guillaud
Xavier Guillaud
MMC is an established technology for HVDC or MTDC systems, due to its advantages over classical Voltage Source Converters (VSCs) such as two or three level VSCs. To achieve a full control of all state variables, it is essential to implement energy-based method in which a cascade control loop is employed to regulate all state variables including ac and differential currents, and stored energy within MMC arms. In addition to normal operation control, dc Fault Ride Through (DC-FRT) capability of the MMC is a crucial and challenging control issue especially for overhead line HVDC system where non-permanent dc fault occurrence is statistically more probable. Furthermore, the main problematic technical obstacle to develop HVDC/MTDC grids is the lack of mature dc fault protection. Since conventional control in normal operation cannot be employed in case of dc fault, an efficient control strategy is indispensable. The principal objectives of the novel control methodology are to obtain DC-FRT capability, decay short circuit current to zero, secure the MMC through leg and arm energy balancing, support ac grid as a STATCOM and resume normal operation after dc fault clearance. The simulation results verify the validity of proposed control strategy to fulfill the abovementioned objectives.

28 September 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
CLChuanyue Li
Chuanyue Li
SWSheng Wang
Sheng Wang
FCFrederic Colas
Frederic Colas
JLJun LIANG
Jun LIANG
In this paper, it is identified that unstable weak grid connection of voltage source inverters (VSIs) is dominantly caused by the current control. In particular, it is found the proportional gain $ k_p$ of conventional PI controller cannot balance the grid voltage impact and damping capability especially when a very weak grid with short circuit ratio (SCR) $ < $ 1.3 is connected. This issue is solved in this paper by simply restructuring the PI controller as an IP controller for current control. This IP controller will not change the tuning method of current control and make this VSI indeed connect to a very weak grid with rated power injection.