Ahmed Hasnain Jalal

Dr. Ahmed Hasnain Jalal

Electrical and Computer Engineering, The University of Texas Rio Grande Valley, Edinburg, Texas, USA
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2018 in ACS Sensors
Verified
Journal Article
Closed access
Ahmed Hasnain JalalAhmed Hasnain Jalal
Ahmed Hasnain Jalal
FAFahmida Alam
Fahmida Alam
SRSohini Roychoudhury
Sohini Roychoudhury
YUYogeswaran Umasankar
Yogeswaran Umasankar
Nezih PalaNezih Pala
Nezih Pala
SBShekhar Bhansali
Shekhar Bhansali

30 March 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
FAFahmida Alam
Fahmida Alam
AAAshfaq Ahmed
Ashfaq Ahmed
Ahmed Hasnain JalalAhmed Hasnain Jalal
Ahmed Hasnain Jalal
ISIshrak Siddiquee
Ishrak Siddiquee
RARabeya Zinnat Adury
Rabeya Zinnat Adury
Nezih PalaNezih Pala
Nezih Pala
Implantable biosensors have evolved to the cutting-edge technology of personalized health care and provide promise for future directions in precision medicine. This is the reason why these devices stand to revolutionize our approach to health and disease management and offer insights into our bodily functions in ways that have never been possible before. This review article tries to delve into the important developments, new materials, and multifarious applications of these biosensors, along with a frank discussion on the challenges that the devices will face in their clinical deployment. In addition, techniques that have been employed for the improvement of the sensitivity and specificity of the biosensors alike are focused on in this article, like new biomarkers and advanced computational and data communicational models. A significant challenge of miniaturized in situ implants is that they need to be removed after serving their purpose. Surgical expulsion provokes discomfort to patients, potentially leading to post-operative complications. Therefore, the biodegradability of implants is an alternative method for removal through natural biological processes. This includes biocompatible materials to develop sensors that remain in the body over longer periods with a much-reduced immune response and better device longevity. However, the biodegradability of implantable sensors is still in its infancy compared to conventional non-biodegradable ones. Sensor design, morphology, fabrication, power, electronics, and data transmission all play a pivotal role in developing medically approved implantable biodegradable biosensors. Advanced material science and nanotechnology extended the capacity of different research groups to implement novel courses of action to design implantable and biodegradable sensor components. But the actualization of such potential for the transformative nature of the health sector, in the first place, will have to surmount the challenges related to biofouling, managing power, guaranteeing data security, and meeting today’s rules and regulations. Solving these problems will, therefore, not only enhance the performance and reliability of implantable biodegradable biosensors but also facilitate the translation of laboratory development into clinics, serving patients worldwide in their better disease management and personalized therapeutic interventions.

19 July 2024 in Polymers
Verified
Journal Article
Open access
PDF file
RTRidma Tabassum
Ridma Tabassum
PSPritu Parna Sarkar
Pritu Parna Sarkar
Ahmed Hasnain JalalAhmed Hasnain Jalal
Ahmed Hasnain Jalal
AAAli Ashraf
Ali Ashraf
Nazmul IslamNazmul Islam
Nazmul Islam
In this research, a novel electrochemical biosensor is proposed based on inducing graphene formation on polyimide substrate via laser engraving. Graphene polyaniline (G-PANI) conductive ink was synthesized by planetary mixing and applied to the working zone of the developed sensor to effectively enhance the electrical signals. The laser-induced graphene (LIG) sensor was used to detect alpha-fetoprotein (AFP) and 17β-Estradiol (E2) in the phosphate buffer saline (PBS) buffer and human serum. The electrochemical performance of the biosensor in determining these biomarkers was investigated by differential pulse voltammetry (DPV) and chronoamperometry (CA). In a buffer environment, alpha-fetoprotein (AFP) and 17β-Estradiol detection range were 4–400 ng/mL and 20–400 pg/mL respectively. The experimental results showed a limit of detection (LOD) of 1.15 ng/mL and 0.96 pg/mL for AFP and estrogen, respectively, with an excellent linear range (R2 = 0.98 and 0.99). In addition, the designed sensor was able to detect these two types of biomarkers in human serum successfully. The proposed sensor exhibited excellent reproducibility, repeatability, and good stability (relative standard deviation, RSD = 0.96%, 1.12%, 2.92%, respectively). The electrochemical biosensor proposed herein is easy to prepare and can be successfully used for low-cost, rapid detection of AFP and E2. This approach provides a promising platform for clinical detection and is advantageous to healthcare applications.

13 February 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FAFahmida Alam
Fahmida Alam
Ahmed Hasnain JalalAhmed Hasnain Jalal
Ahmed Hasnain Jalal
Nezih PalaNezih Pala
Nezih Pala
Alcohol intoxication leads to road accidents, violence, and the deteriorated health of heavy drinkers. Hence, a convenient means to monitor alcohol consumption with an accuracy and selective manner is a demand by law enforcement personnel, service/hospitality industry, or individual drinkers. We report on a label-free, highly sensitive, and selective alcohol immunosensor based on 2D zinc oxide nanoflakes (ZnO-NFs), which were synthesized on gold-coated flexible polyethylene terephthalate substrates using a single-step sonochemical process. Selective detection of alcohol was achieved via ethylglucuronide (EtG) detection by immobilizing EtG antibody (EtG-AB) on the as-synthesized sensing electrodes of ZnO-NFs. The 2D ZnO-NFs provide unique sensing advantages over bulk materials. The cyclic voltammetry and electrochemical impedance spectroscopy measurements demonstrated the sensitivity of 0.032 mA/decade/cm 2 in the concentration range of 1 ng/ml to 100 μg/ml which covered the physiological range. The minimum level of detection was determined much lower than 1 ng/ml. Shelf-life studies showed that the presented EtG sensors can be used over two months after the first use without significant performance degradation. Our method and device would help realizing continuous alcohol monitoring in the wearable platform.

17 May 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
PSPritu Parna Sarkar
Pritu Parna Sarkar
AAAli Ashraf
Ali Ashraf
Ahmed Hasnain JalalAhmed Hasnain Jalal
Ahmed Hasnain Jalal
FAFahmida Alam
Fahmida Alam
Nazmul IslamNazmul Islam
Nazmul Islam
In this research, an interdigitated gear-shaped working electrode is presented for cortisol sensing. Overall, the sensor was designed in a three-electrode system and was fabricated using direct laser scribing. A synthesized conductive ink based on graphene and polyaniline was further employed to enhance the electrochemical performance of the sensor. Scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy were employed for physicochemical characterization of the laser-induced graphene (LIG) sensor. Cortisol, a biomarker essential in detecting stress, was detected both in phosphate-buffered saline (PBS, pH = 7.4) and human serum within a linear range of 100 ng/mL to 100 µg/mL. Ferri/ferrocyanide was employed as the redox probe to detect cortisol in PBS. The electrochemical performance of the developed sensor was assessed via differential pulse voltammetry (DPV), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and chronoamperometry. The electrochemical performance demonstrates high sensitivity and selectivity alongside strong repeatability (relative standard deviation (RSD) = 3.8%, n = 4) and reproducibility (RSD = 5.85%, n = 5). Overall, these results highlight the sensor’s reliability, high sensitivity, and repeatability and reproducibility in the detection of cortisol. The sensor successfully detected cortisol in the complex medium of human serum and effectively distinguished it in a ternary mixture containing cortisol and dopamine. Also, the use of direct laser writing on Kapton film makes the approach cost-effective and thus disposable, making it suitable for chronic stress diagnostics and neurological research applications.

6 April 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
Ahmed Hasnain JalalAhmed Hasnain Jalal
Ahmed Hasnain Jalal
YUYogeswaran Umasankar
Yogeswaran Umasankar
FCFraker Christopher
Fraker Christopher
EPErnesto A. Pretto
Ernesto A. Pretto
SBShekhar Bhansali
Shekhar Bhansali
We envision unmanned aerial vehicles (UAV) for rapid evacuation of critically-ill patients from hazardous locations to health care facilities in safe zones. For safety, medical teams accompany patients to monitor vital signs and titrate anesthesia dose during transport. UAV transports would require continuous automated remote monitoring of both vital signs and of sedative dose to be feasible and safe. Volatile anesthetics (isoflurane) are the only anesthetic agents that can be monitored continuously with infrared spectroscopy (IR) devices; but unsuitable for transport. Our objective is to devise a safe UAV transport protocol incorporating novel technology for gas monitoring. Our group has developed and tested a miniaturized wearable fuel cell sensor that can detect isoflurane gas vapors as low as 40 ppm (within therapeutic range) with a sensitivity of 0.0112 nA ppm−1 cm−2. Ambient signal interference was resolved by principal component analysis (PCA). Data variance of 1st and 2nd principal components was 88.68% and 11.31%, respectively. The PCA regression model reported here can determine accurate Isoflurane concentrations. Electronic IoT platform has been built constituting micro-fuel cell, miniaturized electronic components with Bluetooth. This wearable sensor can be incorporated into a comprehensive life support system for casualty evacuation in conjunction with autonomous UAV emergency medical operations.