Pengcheng Yan

Pengcheng Yan


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YLYULAN LU
YULAN LU
PYPengcheng Yan
Pengcheng Yan
CXChao Xiang
Chao Xiang
DCDeyong Chen
Deyong Chen
Junbo WangJunbo Wang
Junbo Wang
Jian ChenJian Chen
Jian Chen
This paper presents a resonant pressure microsensor with the measurement range of 1 MPa suitable for the soaring demands of industrial gas pressure calibration equipment. The proposed microsensor consists of an SOI layer as a sensing element and a glass cap for vacuum packaging. The sensing elements include a pressure-sensitive diaphragm and two resonators embedded in the diaphragm by anchor structures. The resonators are excited by a convenient Lorentz force and detected by electromagnetic induction, which can maintain high signal outputs. In operation, the pressure under measurement bends the pressure-sensitive diaphragm of the microsensor, producing frequency shifts of the two underlining resonators. The microsensor structures were designed and optimized using finite element analyses and a 4” SOI wafer was employed in fabrications, which requires only one photolithographic step. Experimental results indicate that the Q-factors of the resonators are higher than 25,000 with a differential temperature sensitivity of 0.22 Hz/°C, pressure sensitivities of 6.6 Hz/kPa, and −6.5 Hz/kPa, which match the simulation results of differential temperature sensitivity of 0.2 Hz/°C and pressure sensitivities of ±6.5 Hz/kPa. In addition, characterizations based on a closed-loop manner indicate that the presented sensor demonstrates low fitting errors within 0.01% FS, high accuracy of 0.01% FS in the pressure range of 20 kPa to 1 MPa and temperature range of −55 to 85 °C, and the long-term stability within 0.01% FS in a 156-day period under the room temperature.

7 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
PYPengcheng Yan
Pengcheng Yan
YLYULAN LU
YULAN LU
CXChao Xiang
Chao Xiang
Junbo WangJunbo Wang
Junbo Wang
DCDeyong Chen
Deyong Chen
Jian ChenJian Chen
Jian Chen
This paper presents a temperature-insensitive resonant pressure sensor, which is mainly composed of a silicon-on-insulator (SOI) wafer for pressure measurements and a silicon-on-glass (SOG) cap for vacuum packaging. The variations of pressure under measurement bend the pressure sensitive diaphragm and regulate the intrinsic frequencies of the resonators in the device layer. While, variations of temperature cannot significantly change the intrinsic frequencies of the resonators, due to the SOG cap to offset generated thermal stress. Numerical simulations, based on finite element analysis, were conducted to calculate the residual thermal stress and optimize the sensing structures. Experimental results show that the Q-factors of the resonators are higher than 16,000, with a differential pressure sensitivity of 11.89 Hz/kPa, a nonlinearity of 0.01% F.S and a low fitting error of 0.01% F.S with the pressure varying from 100 kPa to 1000 kPa. In particular, a temperature sensitivity of ~1 Hz/°C was obtained in the range of −45 °C to 65 °C, which is one order of magnitude lower than the previously reported counterparts.

21 November 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
CXChao Xiang
Chao Xiang
YLYULAN LU
YULAN LU
PYPengcheng Yan
Pengcheng Yan
Jian ChenJian Chen
Jian Chen
Junbo WangJunbo Wang
Junbo Wang
DCDeyong Chen
Deyong Chen
This paper presents the analysis and characterization of a resonant pressure microsensor, which employs a temperature compensation method based on differential outputs and a temperature sensor. Leveraging a silicon-on-insulator (SOI) wafer, this microsensor mainly consists of a pressure-sensitive diagram and two resonant beams (electromagnetic driving and electromagnetic induction) to produce a differential output. The resonators were vacuum packaged with a silicon-on-glass (SOG) cap using anodic bonding and the wire interconnection was realized by sputtering an Au film on highly topographic surfaces using a hard mask. After the fabrication of the resonant pressure microsensor, systematic experiments demonstrated that the pressure sensitivity of the presented microsensor was about 0.33 kPa/Hz. Utilizing the differential frequency of the two resonators and the signal from a temperature sensor to replace the two-frequency signals by polynomial fitting, the temperature compensation method based on differential outputs aims to increase the surface fitting accuracy of these microsensors which have turnover points. Employing the proposed compensation approach in this study, the errors were less than 0.02% FS of the full pressure scale (a temperature range of −40 to 85 °C and a pressure range of 200 kPa to 2000 kPa).

23 August 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
YLYULAN LU
YULAN LU
SZSen Zhang
Sen Zhang
PYPengcheng Yan
Pengcheng Yan
YLYadong Li
Yadong Li
JYJie Yu
Jie Yu
Jian ChenJian Chen
Jian Chen
This paper presents resonant pressure micro sensors based on dual double ended tuning fork (DETF) resonators, which are electrostatically excited and piezoresistively detected. In operation, the barometric pressure under measurement bends the pressure sensitive diaphragm functioning as the anchor of DETF resonators and therefore produces eigenfrequency shifts of the resonators. Theoretical analyses and finite element analyses (FEA) were conducted to optimize the key geometries of the DETF resonators with enhanced signal to noise ratios (SNRs). In fabrications, key steps including deep reactive ion etching (DRIE) and anodic bonding were used, where sleeve holes were adopted to form electrical connections, leading to high-efficiency structure layout. Experimental results indicate that the presented micro sensors produced SNRs of 63.70 ± 3.46 dB in the open-loop characterizations and differential sensitivities of 101.3 ± 1.2 Hz/kPa, in the closed-loop characterizations. In addition, pressure cycling tests with a pressure range of 5 to 155 kPa were conducted, revealing that the developed micro sensors demonstrated pressure shifts of 83 ± 2 ppm, pressure hysteresis of 67 ± 3 ppm, and repeatability errors of 39 ± 2 ppm. Thus, the developed resonant pressure micro sensors may potentially function as an enabling tool for barometric pressure measurements.