Dina A. Ragab

Dr. Dina A. Ragab

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2019 in PeerJ
Verified
Journal Article
Open access
PDF file
DRDina A. Ragab
Dina A. Ragab
MSMaha Sharkas
Maha Sharkas
Stephen MarshallStephen Marshall
Stephen Marshall
Jinchang RenJinchang Ren
Jinchang Ren
It is important to detect breast cancer as early as possible. In this manuscript, a new methodology for classifying breast cancer using deep learning and some segmentation techniques are introduced. A new computer aided detection (CAD) system is proposed for classifying benign and malignant mass tumors in breast mammography images. In this CAD system, two segmentation approaches are used. The first approach involves determining the region of interest (ROI) manually, while the second approach uses the technique of threshold and region based. The deep convolutional neural network (DCNN) is used for feature extraction. A well-known DCNN architecture named AlexNet is used and is fine-tuned to classify two classes instead of 1,000 classes. The last fully connected (fc) layer is connected to the support vector machine (SVM) classifier to obtain better accuracy. The results are obtained using the following publicly available datasets (1) the digital database for screening mammography (DDSM); and (2) the Curated Breast Imaging Subset of DDSM (CBIS-DDSM). Training on a large number of data gives high accuracy rate. Nevertheless, the biomedical datasets contain a relatively small number of samples due to limited patient volume. Accordingly, data augmentation is a method for increasing the size of the input data by generating new data from the original input data. There are many forms for the data augmentation; the one used here is the rotation. The accuracy of the new-trained DCNN architecture is 71.01% when cropping the ROI manually from the mammogram. The highest area under the curve (AUC) achieved was 0.88 (88%) for the samples obtained from both segmentation techniques. Moreover, when using the samples obtained from the CBIS-DDSM, the accuracy of the DCNN is increased to 73.6%. Consequently, the SVM accuracy becomes 87.2% with an AUC equaling to 0.94 (94%). This is the highest AUC value compared to previous work using the same conditions.

1 April 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
DRDina A. Ragab
Dina A. Ragab
Omneya AttallahOmneya Attallah
Omneya Attallah
MSmaha sharkas
maha sharkas
Jinchang RenJinchang Ren
Jinchang Ren
Stephen MarshallStephen Marshall
Stephen Marshall

26 October 2019 in Diagnostics
Verified
Journal Article
Open access
PDF file
DRDina A. Ragab
Dina A. Ragab
MSmaha sharkas
maha sharkas
Omneya AttallahOmneya Attallah
Omneya Attallah
Breast cancer is one of the major health issues across the world. In this study, a new computer-aided detection (CAD) system is introduced. First, the mammogram images were enhanced to increase the contrast. Second, the pectoral muscle was eliminated and the breast was suppressed from the mammogram. Afterward, some statistical features were extracted. Next, k-nearest neighbor (k-NN) and decision trees classifiers were used to classify the normal and abnormal lesions. Moreover, multiple classifier systems (MCS) was constructed as it usually improves the classification results. The MCS has two structures, cascaded and parallel structures. Finally, two wrapper feature selection (FS) approaches were applied to identify those features, which influence classification accuracy. The two data sets (1) the mammographic image analysis society digital mammogram database (MIAS) and (2) the digital mammography dream challenge were combined together to test the CAD system proposed. The highest accuracy achieved with the proposed CAD system before FS was 99.7% using the Adaboosting of the J48 decision tree classifiers. The highest accuracy after FS was 100%, which was achieved with k-NN classifier. Moreover, the area under the curve (AUC) of the receiver operating characteristic (ROC) curve was equal to 1.0. The results showed that the proposed CAD system was able to accurately classify normal and abnormal lesions in mammogram samples.

30 September 2020 in PeerJ
Verified
Journal Article
Open access
Omneya AttallahOmneya Attallah
Omneya Attallah
DRDina A. Ragab
Dina A. Ragab
MSMaha Sharkas
Maha Sharkas
Coronavirus (COVID-19) was first observed in Wuhan, China, and quickly propagated worldwide. It is considered the supreme crisis of the present era and one of the most crucial hazards threatening worldwide health. Therefore, the early detection of COVID-19 is essential. The common way to detect COVID-19 is the reverse transcription-polymerase chain reaction (RT-PCR) test, although it has several drawbacks. Computed tomography (CT) scans can enable the early detection of suspected patients, however, the overlap between patterns of COVID-19 and other types of pneumonia makes it difficult for radiologists to diagnose COVID-19 accurately. On the other hand, deep learning (DL) techniques and especially the convolutional neural network (CNN) can classify COVID-19 and non-COVID-19 cases. In addition, DL techniques that use CT images can deliver an accurate diagnosis faster than the RT-PCR test, which consequently saves time for disease control and provides an efficient computer-aided diagnosis (CAD) system. The shortage of publicly available datasets of CT images, makes the CAD system’s design a challenging task. The CAD systems in the literature are based on either individual CNN or two-fused CNNs; one used for segmentation and the other for classification and diagnosis. In this article, a novel CAD system is proposed for diagnosing COVID-19 based on the fusion of multiple CNNs. First, an end-to-end classification is performed. Afterward, the deep features are extracted from each network individually and classified using a support vector machine (SVM) classifier. Next, principal component analysis is applied to each deep feature set, extracted from each network. Such feature sets are then used to train an SVM classifier individually. Afterward, a selected number of principal components from each deep feature set are fused and compared with the fusion of the deep features extracted from each CNN. The results show that the proposed system is effective and capable of detecting COVID-19 and distinguishing it from non-COVID-19 cases with an accuracy of 94.7%, AUC of 0.98 (98%), sensitivity 95.6%, and specificity of 93.7%. Moreover, the results show that the system is efficient, as fusing a selected number of principal components has reduced the computational cost of the final model by almost 32%.

12 October 2020 in PeerJ Computer Science
Verified
Journal Article
Open access
PDF file
DRDina A. Ragab
Dina A. Ragab
Omneya AttallahOmneya Attallah
Omneya Attallah
The precise and rapid diagnosis of coronavirus (COVID-19) at the very primary stage helps doctors to manage patients in high workload conditions. In addition, it prevents the spread of this pandemic virus. Computer-aided diagnosis (CAD) based on artificial intelligence (AI) techniques can be used to distinguish between COVID-19 and non-COVID-19 from the computed tomography (CT) imaging. Furthermore, the CAD systems are capable of delivering an accurate faster COVID-19 diagnosis, which consequently saves time for the disease control and provides an efficient diagnosis compared to laboratory tests. In this study, a novel CAD system called FUSI-CAD based on AI techniques is proposed. Almost all the methods in the literature are based on individual convolutional neural networks (CNN). Consequently, the FUSI-CAD system is based on the fusion of multiple different CNN architectures with three handcrafted features including statistical features and textural analysis features such as discrete wavelet transform (DWT), and the grey level co-occurrence matrix (GLCM) which were not previously utilized in coronavirus diagnosis. The SARS-CoV-2 CT-scan dataset is used to test the performance of the proposed FUSI-CAD. The results show that the proposed system could accurately differentiate between COVID-19 and non-COVID-19 images, as the accuracy achieved is 99%. Additionally, the system proved to be reliable as well. This is because the sensitivity, specificity, and precision attained to 99%. In addition, the diagnostics odds ratio (DOR) is ≥ 100. Furthermore, the results are compared with recent related studies based on the same dataset. The comparison verifies the competence of the proposed FUSI-CAD over the other related CAD systems. Thus, the novel FUSI-CAD system can be employed in real diagnostic scenarios for achieving accurate testing for COVID-19 and avoiding human misdiagnosis that might exist due to human fatigue. It can also reduce the time and exertion made by the radiologists during the examination process.

21 February 2024 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Closed access
PDF file
DRDina A. Ragab
Dina A. Ragab
SFSalema Fayed
Salema Fayed
NGNoha Ghatwary
Noha Ghatwary