The high-strength bolt shear connector in prefabricated concrete slab has advantages in applications as it reduces time during the construction of steel-concrete composite building structures and bridges. In this research, an innovative and advanced bolt shear connector in steel-concrete composite structures is proposed. To investigate the fundamental mechanical behavior and the damage form, 22 static push-off tests were conducted with consideration of different bolt dimensions, the reserved hole constraint condition, and the dimension of slab holes. A finite element (FE) model was established and verified by using test results, and then the model was utilized to investigate the influence of concrete strength, bolt dimension, yield strength, bolt pretension, as well as length-to-diameter ratio of high strength bolts on the performances of shear connectors. On the basis of FE simulation and test results, new design formulas for the calculation of shear resistance behavior were proposed, and comparisons were made with current standards, including AISC, EN 1994-1-1, GB 50017-2017, and relevant references, to check the calculation efficiency. It is confirmed that the proposed equation is in better agreement with the experimental results.
This paper studied the composite action of concrete-filled circular aluminum alloy tubular (CFCAT) stub columns under axial compression. A fine-meshed finite three-dimensional (3D) solid element model making use of a tri-axial plastic-damage constitutive model of concrete and elastoplastic constitutive model of aluminum alloy was established. A parametric study utilizing the verified finite element (FE) model was carried out and the analytical results were exploited to investigate the composite actions of concrete-filled circular aluminum alloy tubular stub columns subjected axial compression. Compared with the concrete-filled steel tube (CFCST) stub columns, the aluminum alloy tube exerted a weaker constraint effect on the infilled concrete due to its lower elastic modulus. Based on the FE analytical results and regression method, the composite action model of concrete-filled circular aluminum alloy tubular stub columns was proposed. By generalizing the stress nephogram of the concrete-filled circular aluminum alloy tubular stub column at the limit state, a design formula was proposed to estimate the ultimate bearing capacity the columns using the superposition method. The predicted results of the proposed formula show a good agreement with both the experimental and FE analytical results. The comparison between the proposed formula and current design methods indicates that the proposed formula is more accurate and convenient to use.
Connections for steel–concrete composite trusses (SCCTs) for bridge applications were investigated. Eight specimens on a scale of 1/3 of the actual bridge were tested under static loading using connections with different gusset plates, including rectangular (RGP), π shape (PSGP), and J shape (JSGP). A detailed account of the design considerations, loading procedure, and experimental parameters is provided. A three-dimensional (3D) finite-element (FE) model was developed to analyze the mechanical behavior of these three composite truss connections. The results of the FE analysis were in good agreement with the experimental results. Both indicated excellent mechanical behavior for the investigated composite truss connections, with sufficient safety factors. The minimum yielding, cracking, and ultimate loads obtained from specimens were 2.65, 2.21, and 3.87 times the design load (907 kN), respectively. All specimens underwent considerable deformation, thereby suggesting satisfactory ductility. The pr...