Muzaffar Ali

Dr. Muzaffar Ali

orcid
Professor, Chairman Department of Energy Engineering, Univer...

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2017 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
Muzaffar AliMuzaffar Ali
Muzaffar Ali
MIMuhammad Hasan Iqbal
Muhammad Hasan Iqbal
NSNadeem Sheikh
Nadeem Sheikh
Hafiz Muhammad AliHafiz Muhammad Ali
Hafiz Muhammad Ali
MMM. Shehryar Manzoor
M. Shehryar Manzoor
KTKhairul Tamrin
Khairul Tamrin
Junction temperature of PV modules is one of the key parameters on which the performance of PV modules depends. In the present work, an experimental investigation was carried out to analyze the effects of air velocity on the performance of two PV modules, that is, monocrystalline silicon and polycrystalline silicon under the controlled conditions of a wind tunnel in the presence of an artificial solar simulator. The parameters investigated include the surface temperature variation, power output, and efficiency of PV modules under varying air velocity from near zero (indoor lab. conditions) to 15 m/s. Additionally, the results were also determined at two different module angular positions: at 0° angle, that is, parallel to air direction and at 10° angle with the direction of coming air to consider the effects of tilt angles. Afterwards, the thermal analysis of the modules was performed using Ansys-Fluent in which junction temperature and heat flux of modules were determined by applying appropriate boundary conditions, such as air velocity, heat flux, and solar radiation. Finally, the numerical results are compared with the experiment in terms of junction temperatures of modules and good agreement was found. Additionally, the results showed that the maximum module temperature drops by 17.2°C and the module efficiency and power output increased from 10 to 12% with increasing air velocity.

1 January 2015 in AIMS Energy
Verified
Journal Article
Open access
PDF file
Muzaffar AliMuzaffar Ali
Muzaffar Ali
HAHafiz.M. Ali
Hafiz.M. Ali
WMWaqar Moazzam
Waqar Moazzam
MSM. Babar Saeed
M. Babar Saeed
Efficiency of a PV cell is strongly dependent on its surface temperature. The current study is focused to achieve maximum efficiency of PV cells even in scorching temperatures in hot climates like Pakistan where the cell surface temperatures can even rise up to around 80 ℃. The study includes both the CFD and real time experimental investigations of a solar panel using micro channel cooling. Initially, CFD analysis is performed by developing a 3D model of a Mono-Crystalline cell with micro-channels to analyze cell surface temperature distribution at different irradiance and water flow rates. Afterwards, an experimental setup is developed for performance investigations under the real conditions of an open climate of a Pakistan's city, Taxila. Two 35W panels are manufactured for the experiments; one is based on the standard manufacturing procedure while other cell is developed with 4mm thick aluminum sheet having micro-channels of cross-section of 1mm by 1mm. The whole setup also includes different sensors for the measurement of solar irradiance, cell power, surface temperature and water flow rates. The experimental results show that PV cell surface temperature drop of around 15 ℃ is achieved with power increment of around 14% at maximum applied water flow rate of 3 LPM. Additionally, a good agreement is also found between CFD and experimental results. Therefore, that study clearly shows that a significant performance improvement of PV cells can be achieved through the proposed cell cooling technique.

21 February 2018 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
GCGhulam Chaudhary
Ghulam Chaudhary
RKRubeena Kousar
Rubeena Kousar
Muzaffar AliMuzaffar Ali
Muzaffar Ali
MAMuhammad Amar
Muhammad Amar
KAKhuram Pervez Amber
Khuram Pervez Amber
ADAllah Ditta
Allah Ditta
The current study presents a numerical and real-time performance analysis of a parabolic trough collector (PTC) system designed for solar air-conditioning applications. Initially, a thermodynamic model of PTC is developed using engineering equation solver (EES) having a capacity of around 3 kW. Then, an experimental PTC system setup is established with a concentration ratio of 9.93 using evacuated tube receivers. The experimental study is conducted under the climate of Taxila, Pakistan in accordance with ASHRAE 93-1986 standard. Furthermore, PTC system is integrated with a solid desiccant dehumidifier (SDD) to study the effect of various operating parameters such as direct solar radiation and inlet fluid temperature and its impact on dehumidification share. The experimental maximum temperature gain is around 5.2°C, with the peak efficiency of 62% on a sunny day. Similarly, maximum thermal energy gain on sunny and cloudy days is 3.07 kW and 2.33 kW, respectively. Afterwards, same comprehensive EES model of PTC with some modifications is used for annual transient analysis in TRNSYS for five different climates of Pakistan. Quetta revealed peak solar insolation of 656 W/m2 and peak thermal energy 1139 MJ with 46% efficiency. The comparison shows good agreement between simulated and experimental results with root mean square error of around 9%.

7 December 2022 in Buildings
Verified
Journal Article
Open access
PDF file
MRMuhammad Rizwan Rana
Muhammad Rizwan Rana
SAShehbaz Ahmad
Shehbaz Ahmad
SSSyed Nasir Shah
Syed Nasir Shah
Muzaffar AliMuzaffar Ali
Muzaffar Ali
MSMansoor Ul Hassan Shah
Mansoor Ul Hassan Shah
Jaroslaw KrzywanskiJaroslaw Krzywanski
Jaroslaw Krzywanski
Reducing energy consumption in buildings has received intensified research impetus since the introduction of the decarbonization goals set in the Paris agreement. Many domestic and specialized applications require clean rooms (indoor built environments) for safe and clean operation. Energy efficiency in clean room spaces depends on maintaining livable or required conditions such as temperature, humidity, and particle concentration with minimal use of energy and new carbon dioxide (CO2) emissions. In the literature, parameters such as temperature, relative humidity, particle concentrations, and CO2 emissions are not able to be properly controlled in clean room systems. The designed system in the literature involves high energy consumption and high economic costs. All these factors add novelty to this research, which was a significant research gap in previous studies. This clean room is directly linked to environmental parameters such as ambient temperature, relative humidity, etc. The clean room is also related directly to the building and infrastructure in such a way that there are certain regulatory requirements for designing a clean room. For designing and constructing the controlled environment in a clean room, the English (EN) documents, ISO 9000, and various other standards allow for clean rooms for different types of products. In this research, the designed control configurations properly control the system. Additionally, this system is energy efficient, with positive environmental aspects regarding CO2 emissions. Three control configurations were designed in this research, option A, option B, and option C, and three parameters are controlled in the study. These parameters are room temperature, relative humidity, and CO2 emissions (outside the room). CO2 emissions are controlled outside the room (in the environment). In the last research phase, a comparative analysis of these three control configurations was performed to find an energy-efficient system with fewer CO2 emissions. Control configuration B (option B) provides reliable results regarding an energy-efficient system and fewer CO2 emissions emitted to the environment. In this study, an optimized configuration for the air conditioning system was developed for a clean room (volume 185.6 m3) with a required temperature of 23 °C, relative humidity of 40%, and a particle size of less than 0.3 μm. Three different design configurations were analyzed using TRNSYS simulation software. The minimization of energy use and CO2 emissions were the objective functions. Energy loads were calculated for each of the configurations by varying the fixed air change per hour and the minimum outdoor air flow rate. The results of a whole year simulation run for control configurations A, B, and show that, on the one hand, the ambient weather conditions of temperature and relative humidity (RH) is varied throughout year and, on the other hand, the clean room temperature was maintain at exactly 23 °C, which is the required set point temperature, for all the three configurations (A, B, and C). Furthermore, the clean room relative humidity was maintained at 36% for configuration A, below the 40% which was the set point for clean room relative humidity, and at 40% for configurations B and C. Configuration B exhibited the minimum energy use (7300 kWh), at a fixed air change per hour value of 20 and a minimum outdoor air flow rate of 150 L/s, with the least amount of CO2 emissions, offering an overall 25% improvement over configurations A and C.

5 December 2024 in Energy
Verified
Journal Article
Closed access
Muzaffar AliMuzaffar Ali
Muzaffar Ali
Sabir RasheedSabir Rasheed
Sabir Rasheed
MMMohammad Mohsin
Mohammad Mohsin
SHSuoying He
Suoying He
Muslum AriciMuslum Arici
Muslum Arici
GLGuiqiang Li
Guiqiang Li

30 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
JAJAVED AKHTER
JAVED AKHTER
SGSyed I. Gilani
Syed I. Gilani
Hussain H. Al-KayiemHussain H. Al-Kayiem
Hussain H. Al-Kayiem
Muzaffar AliMuzaffar Ali
Muzaffar Ali
Compound parabolic concentrating (CPC) collectors have great potential to provide sustainable solar thermal energy for many applications operating in the medium temperature range. This paper presents the design, development and performance evaluation of a modified CPC collector integrated with an evacuated tube receiver. The optical performance of the designed CPC paired with concentric tube receiver is compared with that of a CPC coupled with single flow through evacuated tube receiver for stationary installation in the East-West and North-South directions. Ray tracing simulations of different configurations demonstrate that CPC coupled with single flow through receivers suffer high gap losses, especially at smaller incidence angles which are considerably alleviated by a concentric tube receiver arrangement. East-West installation of CPC paired with concentric tube receiver exhibited superior optical performance than all other configurations. The yearly average optical efficiency of CPC with concentric tube receiver was 5% higher than that of a single flow through receiver within the acceptance angle. A 60% truncated CPC coupled with concentric tube receiver emerged as the most effective design, which was fabricated for experimental testing. The tests conducted under actual outdoor tropical environmental conditions demonstrated that the experimental optical efficiency reached to about 69% in the case of N-S installation and 66.5% in an E-W arrangement. The experimental results closely match the simulation outcomes, which indicate the proposed performance prediction technique as instrumental for selecting the most effective configuration of CPC collectors for medium temperature heat supply.