Ángel Álvarez-Arenal

Dr. Ángel Álvarez-Arenal

Department of Surgery and Surgical Specialties, School of Medicine and Health Sciences, University of Oviedo, 33006 Oviedo, Spain

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2018 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
ÁÁÁngel Álvarez-Arenal
Ángel Álvarez-Arenal
LALeticia Alvarez‐Menendez
Leticia Alvarez‐Menendez
IGIgnacio Gonzalez‐Gonzalez
Ignacio Gonzalez‐Gonzalez
JAJose Antonio Alvarez‐Riesgo
Jose Antonio Alvarez‐Riesgo
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
HDHector Dellanos‐Lanchares
Hector Dellanos‐Lanchares

IGIgnacio Gonzalez-Gonzalez
Ignacio Gonzalez-Gonzalez
HDHector Dellanos-Lanchares
Hector Dellanos-Lanchares
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
JAJosé Alvarez
José Alvarez
SLSantiago Llorente-Pendas
Santiago Llorente-Pendas
ÁÁÁngel Álvarez-Arenal
Ángel Álvarez-Arenal
We aimed to assess the biological and mechanical-technical complications and survival rate of implants of full-arch metal-ceramic prostheses, during five years of follow-up. 558 implants (of three different brands) retaining 80 full-arch metal-ceramic prostheses were placed in 65 patients, all of whom were examined annually for biological and mechanical-technical complications during the five years of follow-up. Descriptive statistics and univariate logistic regression were calculated. The cumulative survival rate of the implants was 99.8%, and 98.8% prosthesis-based. Mucositis was the most frequent of the biological complications and peri-implantitis was recorded as 13.8% at restoration-level, 16.9% at patient level and 2.0% at implant level. An implant length greater than 10 mm was shown to be a protective factor against biological complications. The mechanical-technical complications were associated with implant diameter, abutment/implant connection and retention system. Loss of screw access filling was the most frequent prosthetic complication, followed by the fracture of the porcelain. Full-arch metal-ceramic prostheses show a high prevalence of implant and prosthesis survival, with few biological and mechanical-technical complications.

1 April 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
EMElena Martin-Fernandez
Elena Martin-Fernandez
IGIgnacio Gonzalez-Gonzalez
Ignacio Gonzalez-Gonzalez
HDHector Dellanos-Lanchares
Hector Dellanos-Lanchares
MMMario Andres Mauvezin-Quevedo
Mario Andres Mauvezin-Quevedo
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
ÁÁÁngel Álvarez-Arenal
Ángel Álvarez-Arenal
Purpose. The purpose of this study was to evaluate and compare the effect of three mandibular full-arch superstructures on the peri-implant bone stress distribution during mandibular flexure caused by mid-opening (27 mm) and protrusion mandibular movements. Materials and Methods. Three-dimensional finite element models were created simulating six osseointegrated implants in the jawbone. One model simulated a 1-piece framework and the other simulated 2-piece and 3-piece frameworks. Muscle forces with definite direction and magnitude were exerted over areas of attachment to simulate multiple force vectors of masticatory muscles during mandibular protrusion and opening. Results. During the movement of 27.5 mm jaw opening, the 1-piece and 3-piece superstructures showed the lowest values of bone stress around the mesial implants, gradually increasing towards the distal position. During the protrusion movement, bone stress increased compared to opening for any implant situation and for a divided or undivided framework. The 3-piece framework showed the highest values of peri-implant bone stress, regardless of the implant situation. Conclusions. The undivided framework provides the best biomechanical environment during mandibular protrusion and opening. Protrusion movement increases the peri-implant bone stress. The most mesial implants have the lowest biomechanical risk.

31 October 2020 in Biology
Verified
Journal Article
Open access
PDF file
MGMarta García González
Marta García González
SBSergio Blasón-González
Sergio Blasón-González
IGIsmael García García
Ismael García García
MRMaría Jesús Lamela Rey
María Jesús Lamela Rey
Alfonso Fernández-CanteliAlfonso Fernández-Canteli
Alfonso Fernández-Canteli
ÁÁÁngel Álvarez-Arenal
Ángel Álvarez-Arenal
Mechanical complications in implant-supported fixed dental prostheses are often related to implant and prosthetic design. Although the current ISO 14801 provides a framework for the evaluation of dental implant mechanical reliability, strict adherence to it may be difficult to achieve due to the large number of test specimens which it requires as well as the fact that it does not offer any probabilistic reference for determining the endurance limit. In order to address these issues, a new software program called ProFatigue is presented as a potentially powerful tool to optimize fatigue testing of implant-supported prostheses. The present work provides a brief description of some concepts such as load, fatigue and stress-number of cycles to failure curves (S-N curves), before subsequently describing the current regulatory situation. After analyzing the two most recent versions of the ISO recommendation (from 2008 and 2016), some limitations inherent to the experimental methods which they propose are highlighted. Finally, the main advantages and instructions for the correct implementation of the ProFatigue free software are given. This software will contribute to improving the performance of fatigue testing in a more accurate and optimized way, helping researchers to gain a better understanding of the behavior of dental implants in this type of mechanical test.

1 June 2020 in EP Europace
Verified
Journal Article
Open access
PDF file
LBLucas Boersma
Lucas Boersma
EKEdward Kozluk
Edward Kozluk
GMGiampiero Maglia
Giampiero Maglia
João Carlos SousaJoão Carlos Sousa
João Carlos Sousa
OGOlaf Grebe
Olaf Grebe
AGAndreas Goette
Andreas Goette
Aims: The GOLD AF Registry has been designed to prospectively assess the population, indications, and outcomes using second-generation phased radiofrequency (RF) ablation (pulmonary vein ablation catheter GOLD) in a global examination of standard-of-care use for the treatment of paroxysmal and persistent atrial fibrillation (AF). Methods and results: GOLD AF (NCT02433613) is a prospective, observational, multi-centre registry designed to characterize efficacy and safety of phased RF ablation in patients with AF. The primary endpoint was freedom from AF recurrence at 12-month follow-up after a 90-day blanking period. Ancillary objectives include safety, procedural efficiency, and quality of life (QoL). The QoL assessment using the Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) and the European Heart Rhythm Association (EHRA) Score of AF-related symptoms was collected at baseline and 12 months. In total, 1054 patients were included in this analysis (age 60.6, 67.6% male, 26.5% PersAF). Kaplan–Meier estimate of freedom from AF recurrence was 77.7% at 12 months. Peri-procedural device or procedure-related complications were observed in 26 (2.5%) patients, with a low stroke rate of 0.3%. One-year post-ablation, the EHRA AF Symptom score decreased in 68% of patients. The AFEQT score improvement was observed in 88.4% and 90.4% of patients who completed the questionnaire in-person or interviewed by phone at 12 month follow-up, respectively. Conclusion: Phased RF ablation for the treatment of paroxysmal and persistent AF demonstrated a 77.7% freedom from AF recurrence at 12 months in addition to a significant reduction in arrhythmia symptoms and clinically meaningful improved QoL. Low peri-procedural complication rate of <3% was reported.

1 January 2013 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
ÁÁÁngel Álvarez-Arenal
Ángel Álvarez-Arenal
LSLuis Segura-Mori
Luis Segura-Mori
IGIgnacio Gonzalez-Gonzalez
Ignacio Gonzalez-Gonzalez
AGAngel Gago
Angel Gago
Angel Alvarez-Arenal, DDS, PhD/Luis Segura-Mori, DDS/Ignacio Gonzalez-Gonzalez, DDS, PhD/Angel Gago, DDS: Purpose: Three-dimensional finite element analysis was conducted to evaluate and compare the stress distribution in the abutment and retention screw of implant-supported single crowns with platform switching and with a conventional platform under vertical and oblique loading. Materials and Methods: Two finite element models were created simulating an osseointegrated implant (4 ? 10 mm, platform 4.1 mm) embedded in jawbone. One model simulated a 4-mm-diameter abutment connection (conventional model) and the other represented a 3.8-mm-diameter abutment connection (platform-switched model). A crown with a cobalt-chromium framework and feldspathic porcelain veneering was applied to the titanium abutment. Static vertical and oblique loads were applied to the crown, with a maximum load of 150 N. Results: In both models, the highest stress values occurred in the abutment during vertical and oblique loading. Nevertheless, the von Mises stresses in the abutment and the retention screw were lower in the platform-switched model than in the conventional model. During axial loading, the abutment and screw supported slightly less stress in the conventional model than in the platform-switched model. Increases in the angle of force application caused a progressive increase in stresses in the abutment and screw in both models. The maximum stress was distributed at the margin and transgingival area of the abutment and on two-thirds of the flat area and the first threads of the retention screw in both models. Conclusions: Platform switching reduced the stress values on the abutment and retention screw of a single-unit prosthesis during oblique loading. Regardless of whether platform switching was employed, the stress on the abutment and screw gradually increased as the loading direction changed from vertical to 45 degrees oblique. The locations and distributions of stresses were similar in both models. Int J Oral Maxillofac Implants 2013;28:e112?e121. doi: 10.11607/jomi.2813