The load transfer from metallic prosthesis to tissue plays an important role in the success of a designed device. From a mechanical behavior point of view, the load transfer will be favored when the elastic modulus between the metallic implant and the bone tissue are similar. Titanium and Ti-6Al-4V are the most commonly used metals and alloys in the field of dental implants, although they present high elastic moduli and hence trigger bone resorption. We propose the use of low-modulus β-type titanium alloys that can improve the growth of new bone surrounding the implant. We designed dental implants with identical morphology and micro-roughness composed of: Ti-15Zr, Ti-19.1Nb-8.8Zr, Ti-41.2Nb-6.1Zr, and Ti-25Hf-25Ta. The commercially pure Ti cp and Ti-6Al-4V were used as control samples. The alloys were initially mechanically characterized with a tensile test using a universal testing machine. The results showed the lowest elastic modulus for the Ti-25Hf-25Ta alloy. We implanted a total of six implants in the mandible (3) and maxilla (3) for each titanium alloy in six minipigs and evaluated their bone index contact (i.e., the percentage of new bone in contact with the metal—BIC%) after 3 and 6 weeks of implantation. The results showed higher BIC% for the dental implants with lowest elastic modulus, showing the importance of decreasing the elastic modulus of alloys for the successful osseointegration of dental implants.
1 December 2015 in The Journal of Prosthetic Dentistry
The purpose of this study was to locate the 3D spatial position mandibular cast and determine its occlusal contacts in a novel way by using an intraoral scanner as part of the virtual occlusal record procedure. This study also analyzes the requirements in quantity and dimensions of the intraoral virtual occlusal record. The results showed that the best section combination consists of 2 lateral and frontal sections, the width of this section being that of 2 teeth (24 mm × 15 mm). This study concluded that this procedure was accurate enough to locate the mandibular cast on a virtual articulator. However, at least 2 sections of the virtual occlusal records were necessary, and the best results were obtained when the distance between these sections was maximum.
The objective of the present study is to evaluate how the elastic properties of the fabrication material of dental implants influence peri-implant bone load transfer in terms of the magnitude and distribution of stress and deformation. A three-dimensional (3D) finite element analysis was performed; the model used was a section of mandibular bone with a single implant containing a cemented ceramic-metal crown on a titanium abutment. The following three alloys were compared: rigid (Y-TZP), conventional (Ti-6Al-4V), and hyperelastic (Ti-Nb-Zr). A 150-N static load was tested on the central fossa at 6° relative to the axial axis of the implant. The results showed no differences in the distribution of stress and deformation of the bone for any of the three types of alloys studied, mainly being concentrated at the peri-implant cortical layer. However, there were differences found in the magnitude of the stress transferred to the supporting bone, with the most rigid alloy (Y-TZP) transferring the least stress and deformation to cortical bone. We conclude that there is an effect of the fabrication material of dental implants on the magnitude of the stress and deformation transferred to peri-implant bone.
Purpose: To evaluate the micromobility of dental implants under occlusal loading in relation to stability measurements of resonance frequency analysis and insertion torque. Materials and Methods: The sample comprised of 24 implants inserted in 12 fresh cow ribs. Insertion torque and Osstell implant stability quotient (ISQ) measurements were recorded. An “ad hoc” acrylic premolar was made on a temporary abutment and screwed to each implant, and a force of 100 N was subsequently applied at an angle of 6 degrees. Implant micromotion was measured using a Questar microscope with a resolution of 2 μm and an image analysis program. Results: Data show a statistically significant inverse correlation between the ISQ values and implant micromotion under a load of 100 N (R2 = 0.86, P < 0.0001). The same relationship is found between insertion torque and implant micromotion, although the relationship is linear up to 34 N·cm and becomes exponential for higher values (R2 = 0.78, P < 0.0001). A direct correlation is established between insertion torque and ISQ values. Conclusion: There is an inverse relationship between both ISQ and insertion torque values and implant micromotion under a load of 100 N.