Magnetic induction tomography (MIT) is a non-invasive and non-contact imaging technology, which can be used in medical diagnosis by reconstructing the electrical distribution of biological tissues. Unlike other large medical imaging equipment, the device of MIT is with small size and low cost. The theoretical basis of MIT is by measuring the phase difference of magnetic flux density generated around the imaging objects, analyzing the eddy current distribution, and then using the reconstruction algorithms to obtain the electrical characteristic distribution of the object. This review introduces the development of imaging systems and the reconstruction algorithms of MIT as a medical assisted diagnostic technology, including the optimal design of the sensors, the excitation methods of the system, the calculation methods of the eddy current, and the improved methods of different reconstruction algorithms.
Transcranial electrical stimulation (tES) can adjust the membrane potential by applying a weak current on the scalp to change the related nerve activity. In recent years, tES has proven its value in studying the neural processes involved in human behavior. The study of central auditory processes focuses on the analysis of behavioral phenomena, including sound localization, auditory pattern recognition, and auditory discrimination. To our knowledge, studies on the application of tES in the field of hearing and the electrophysiological effects are limited. Therefore, we reviewed the neuromodulatory effect of tES on auditory processing, behavior, and cognitive function and have summarized the physiological effects of tES on the auditory cortex.
Breast cancer is a malignant tumor disease for which early detection, diagnosis, and treatment are of paramount significance in prolonging the life of patients. Magnetic Detection Electrical Impedance Tomography (MDEIT) based on the Convolutional Neural Network (CNN), which aims to realize non-invasive, high resolution detection of breast tumors, is proposed. First, the MDEIT forward problem of the coronal and horizontal planes of the breast was simulated and solved using the Finite Element Method to obtain sample datasets of different lesions. Then, the CNN was built and trained to predict the conductivity distribution in different orientations of the breast model. Finally, noise and phantom experiments were performed in order to assess the anti-noise performance of the CNN algorithm and its feasibility of detecting breast tumors in practical applications. The simulation results showed that the reconstruction relative error with the CNN algorithm can be reduced to 10%, in comparison with the truncated singular value decomposition algorithm and back propagation algorithm. The CNN algorithm had better stability in the anti-noise performance test. When the noise of 60 dB was added, the shape of the breast tumor could still be restored by the CNN algorithm. The phantom experimental results showed that through the CNN based reconstruction algorithm, the reconstruction conductivity distribution image was legible and the position of the breast tumor could be determined. It is reasonable to conclude that the MDEIT reconstruction method proposed in this study has practical importance for the early and non-invasive detection of breast tumors.
Magnetic detection electrical impedance tomography (MDEIT) is a novel imaging technique that aims to reconstruct the conductivity distribution with electrical current injection and the external magnetic flux density measurement by magnetic sensors. Aiming at improving the resolution and accuracy of MDEIT and providing an efficient imaging method for breast cancer diagnosis, a new algorithm based on stacked auto-encoder (SAE) neural network is proposed. Both numerical simulation and phantom experiments are done to verify its feasibility. In the numerical simulation, an amount of sample data with different conductivity distribution are calculated. Then a neural network model is established and trained by training these samples. Finally, the conductivity distribution of an imaging target with the anomaly location can be reconstructed by the network model. The reconstruction result of the SAE algorithm is compared with the reconstruction results of the traditional sensitivity matrix (SM) algorithm and the back propagation (BP) neural network algorithm. Under the noise of 30dB, the relative errors of BP algorithm, SM algorithm and SAE algorithm are 137.19%, 24.90% and 15.28% respectively. Result shows by the SAE algorithm, the location of anomalies is reconstructed more accurately, the conductivity value is more closely to the real one and the anti-noise performance is more robust. At last, a breast phantom experiment by self-made platforms is completed to verify the application feasibility of the new algorithm. The relative reconstruction error of conductivity by proposed SAE algorithm can be reduced to 14.56%. The results show that by SAE algorithm, MDEIT can be a promising approach in clinical diagnosis of breast cancer, and it also provide more potential application prospect for the extensive application of MDEIT.
Magnetic induction tomography (MIT) is a non-invasive and non-contact imaging method that uses an excitation coil to generate time-varying magnetic fields in space and reconstruct the internal conductivity distribution based on the phase difference. In this study, a new MIT reconstruction algorithm was proposed for non-contact measurement and monitoring of the location of the anomaly in the biomedical object of interest. To reconstruct the distribution of electrical characteristics inside the biological tissue, this technique uses a stacked auto-encoder (SAE) neural network composed of a multi-layer automatic encoder. The location and reconstruction accuracy of the anomaly based on SAE and back-projection were compared, and a hemorrhagic stroke was simulated to verify the practicability of the proposed algorithm. The results showed that the relative error of reconstruction based on the SAE network algorithm reached 0.29%, which improved anomaly reconstruction accuracy and reduced the prediction time to 0.02 s. At the same time, the network was used for the reconstruction of hemorrhagic stroke in different locations, amounts, and shapes. Accordingly, the SAE neural network reconstruction algorithm proposed in this study, which can autonomously learn the non-linear relationship between input and output, can solve the defects of the traditional reconstruction algorithm, such as serious artifacts and complex calculations.
The identification of fatigue in personal workers in particular environments can be achieved through early warning techniques. In order to prevent excessive fatigue of medical workers staying in infected areas in the early phase of the coronavirus disease pandemic, a system of low-load wearable electrocardiogram (ECG) devices was used as intelligent acquisition terminals to perform a continuous measurement ECG collection. While machine learning (ML) algorithms and heart rate variability (HRV) offer the promise of fatigue detection for many, there is a demand for ever-increasing reliability in this area, especially in real-life activities. This study proposes a random forest-based classification ML model to identify the four categories of fatigue levels in frontline medical workers using HRV. Based on the wavelet transform in ECG signal processing, stationary wavelet transform was applied to eliminate the main perturbation of ECG in the motion state. Feature selection was performed using ReliefF weighting analysis in combination with redundancy analysis to optimize modeling accuracy. The experimental results of the overall fatigue identification achieved an accuracy of 97.9% with an AUC value of 0.99. With the four-category identification model, the accuracy is 85.6%. These results proved that fatigue analysis based on low-load wearable ECG monitoring at low exertion can accurately determine the level of fatigue of caregivers and provide further ideas for researchers working on fatigue identification in special environments.