Breast cancer is a malignant tumor disease for which early detection, diagnosis, and treatment are of paramount significance in prolonging the life of patients. Magnetic Detection Electrical Impedance Tomography (MDEIT) based on the Convolutional Neural Network (CNN), which aims to realize non-invasive, high resolution detection of breast tumors, is proposed. First, the MDEIT forward problem of the coronal and horizontal planes of the breast was simulated and solved using the Finite Element Method to obtain sample datasets of different lesions. Then, the CNN was built and trained to predict the conductivity distribution in different orientations of the breast model. Finally, noise and phantom experiments were performed in order to assess the anti-noise performance of the CNN algorithm and its feasibility of detecting breast tumors in practical applications. The simulation results showed that the reconstruction relative error with the CNN algorithm can be reduced to 10%, in comparison with the truncated singular value decomposition algorithm and back propagation algorithm. The CNN algorithm had better stability in the anti-noise performance test. When the noise of 60 dB was added, the shape of the breast tumor could still be restored by the CNN algorithm. The phantom experimental results showed that through the CNN based reconstruction algorithm, the reconstruction conductivity distribution image was legible and the position of the breast tumor could be determined. It is reasonable to conclude that the MDEIT reconstruction method proposed in this study has practical importance for the early and non-invasive detection of breast tumors.
One of the main challenges in the noninvasive sensing of blood glucose by near-infrared (NIR) spectroscopy is the background variations from light source drift, sweating, and temperature change at the human–machine interface. In this paper, a differential correction method based on the spectra from the floating-reference position and measuring position is proposed to eliminate these spectral variations from background interferences. Its effectiveness was validated by in vitro and in vivo experiments in which the diffuse reflectance of intralipid solutions and human skin was collected at the source distances of 0.6 mm and 2 mm by the custom-built system with six super-luminescent emitting diodes (SLEDs) light source. The results showed that, for the in vitro experiments of intralipid solutions, the coefficients of variations of diffuse reflectance decreased by 20.5% under all the six wavelengths after differential correction. For the in vivo experiments of oral glucose tolerance tests (OGTTs), partial least squares (PLS) regression models between glucose concentrations and the diffuse reflectance from palm skin were built, and the root mean square error of cross validation (RMSECV) decreased by 38.0% on average after the differential correction. Further, the spectra of the oral water tolerance tests (OWTTs) were collected for correlation with glucose concentration in OGTTs, and their correlation coefficients (R) decreased by 35.0% on average after the differential correction. Therefore, this differential correction method based on the spectra from the floating-reference position and measuring position can weaken the influence of background variations on the NIR spectroscopy and has promising potential in in vivo detection, especially for noninvasive blood glucose measurement.
The diffuse optical tomography (DOT) technique which uses the traditional linear iterative algorithm has the problems of slow calculation speed and low reconstruction imaging accuracy in the inverse problem reconstruction, which limits its clinical application and development. This paper proposes an inverse-problem solving technology based on a stacked auto-encoder (SAE) network to improve the reconstruction accuracy of anomaly position, size and absorption coefficient in tissues. The reconstruction accuracy of anomaly position, size and absorption coefficient obtained by the traditional algebraic reconstruction technique (ART) method and the SAE based method are experimentally compared. The experimental results show that the SAE based method achieves the prediction accuracy of anomaly position of 96.25%, thus improving the accuracy and shortening the reconstruction time compared with the traditional ART method. Accordingly, the proposed method provides a better solution to the problem of the inaccurate reconstruction of the position and size of the rapid DOT based positioning of anomalies.
A method to estimate the absorbance spectrum caused by the variation in the concentration of a substance in a medium at the optimum pathlength for every wavelength on a wide waveband without adjusting the cell’s size precisely was presented in the paper. This spectrum could be used to evaluate the absorption of certain substance at the optimum pathlength at each wavelength, instead of using a uniform pathlength like absorption coefficient. And the absorbance spectra of glucose in aqueous solution at optimum pathlength for every wavelength at 900–2500 nm were estimated by using this method. Moreover, the glucose absorbance spectra show an unexpected result that the absorption peaks at different overtones of the oxygen–hydrogen and carbon–hydrogen bonds are of similar amplitudes.
We present a floating reference position (FRP)-based drift correction method for near-infrared (NIR) spectroscopy-based long-term blood glucose concentration (BGC) monitoring. Previously, we reported that it is difficult to quantify the systematic drift caused by the fluctuation of incident light intensity at different source–detector (SD) separations based on the absolute FRP change. We use the relative FRP change as a baseline reference to quantitatively characterize the signal drift at different SD separations. For the wavelengths that were used, a uniform equation was developed to describe the relationship between the drift and the relative FRP change. With the help of this equation, the correction can easily be performed by subtracting the systematic drift estimated by the equation. A theoretical analysis and an experimental phantom study demonstrated that our method could be used for systematic drift correction in NIR spectroscopy for long-term BGC monitoring. Moreover, the analysis method can also be referenced to reduce drifts from multiple sources.