Younghoon Kwak

Dr. Younghoon Kwak

University of Seoul, Department of Architecture

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
YKYounghoon Kwak
Younghoon Kwak
JKJeong-A Kang
Jeong-A Kang
JHJung-Ho Huh
Jung-Ho Huh
Taehyoung KimTaehyoung Kim
Taehyoung Kim
YJYoung Sun Jeong
Young Sun Jeong
This paper examines the effectiveness of South Korea’s policy for reducing greenhouse gas (GHG) emissions in office buildings and evaluates if national targets can be met. A sample of office buildings was categorized into two groups—conventional (Group A) and new (Group B)—based on when their construction was approved. Furthermore, data regarding the three design elements of the building envelope, that is building form, window systems, and U-values were collected. By statistically processing data of each element, reference building models were developed and a case study was conducted for each building. Design changes that were incorporated, keeping in mind the GHG reduction policy, showed 13.1% of saving energy in case 8 (reference building of Group B) than case 1 (reference building of Group A). The savings in case 8 were more than the average GHG reduction rate (12.8%) compared to business as usual (BAU). However, case 4 (a conventional (Group A) building form with new (Group B) window systems and U-values) achieved the greatest savings in building loads. The policy to enhance insulation in new buildings to reduce GHG emissions in the building sector has prompted changes in building forms and window systems and has reduced emissions by 10%, that is 3% more than the expected value. Thus, new innovations in building envelope design could achieve an average 12.8% reduction in emissions in buildings.

17 September 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
SMSunhye Mun
Sunhye Mun
YKYounghoon Kwak
Younghoon Kwak
YKYeonjung Kim
Yeonjung Kim
JHJung-Ho Huh
Jung-Ho Huh
In this study a quantitative analysis was performed on the effect on thermal comfort of the stand fan, a personal cooling device that creates local air currents. A total of 20 environmental conditions (indoor temperatures: 22, 24, 26, 28, and 30 °C; fan modes: off, low (L) mode, medium (M) mode, and high (H) mode) were analyzed using questionnaires on male and female subjects in their 20s and a thermal manikin test. The contents of the questionnaire consisted of items on thermal sensation, thermal comfort, thermal acceptability, and demands on changes to the air velocity. This step was accompanied by the thermal manikin test to analyze the convective heat transfer coefficient and cooling effect quantitatively by replicating the stand fan. Given that this study provides data on the cooling effect of the stand fan in quantitative values, it allows for a comparison of energy use with other cooling systems such as the air conditioner, and may be used as a primary data set for analysis of energy conservation rates.

25 January 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
SMSun-hye Mun
Sun-hye Mun
YKYounghoon Kwak
Younghoon Kwak
JHJung-Ho Huh
Jung-Ho Huh
The behavior of building occupants has been studied by researchers for building control as well as for predicting energy use. In this study, we analyzed the effect of the application of single and complex behavior models on the simulation results of residential buildings. Two occupant behaviors—window opening and closing and air conditioner (AC) usage—were simulated, which are known to be interconnected. This study had two purposes: The first was to integrate data analysis tools (R in this study) and building simulation tools (EnergyPlus in this study) so that two behaviors with interconnectivity could be reflected in building simulation analysis. The second purpose was to apply the behavior models in residential buildings to an integrated simulation environment in stages to analyze their relative influence on the building energy and indoor environment. The results of the study prove that the application of complex behavior is important for research regarding the prediction of actual energy consumption. The results help identify the gap between reality and the existing simulation methods; thereby, they can help improve methods related to energy consumption analysis. We hope that this study and its results will serve as a guide for researchers looking to study occupants’ behavior in the future.

12 August 2023 in Heliyon
Verified
Journal Article
Open access
HSHakjong Shin
Hakjong Shin
YKYounghoon Kwak
Younghoon Kwak
JHJung-Ho Huh
Jung-Ho Huh
Livestock facilities commonly generate NH3, a hazardous substance that may also harm livestock. Therefore, monitoring of NH3 concentrations in livestock facilities is necessary to ensure proper control. However, NH3 is alkaline and toxic, causing corrosion inside detection sensors and making monitoring difficult. This study proposes a virtual sensor concept to complement the durability of NH3 physical sensors. The study also conducts a long-term performance validation of a data-driven NH3 concentration prediction model. Results indicate that the model's prediction performance declines sharply when the data generation pattern inside the livestock facility changes due to changes in outdoor conditions and facility operation. Furthermore, the prediction performance of the model differed depending on the training data period settings when updating the model. Hence, the model needs versioning and update management to respond to the data generation pattern in the livestock facility when operating the NH3 concentration virtual sensor. The virtual sensor is expected to enhance monitoring and reduce sensor management costs in livestock facilities.

6 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
YKYounghoon Kwak
Younghoon Kwak
JKJeonga Kang
Jeonga Kang
SMSun-hye Mun
Sun-hye Mun
YJYoung Sun Jeong
Young Sun Jeong
JHJung-Ho Huh
Jung-Ho Huh
This paper proposes a flexible modeling approach to develop a theoretical reference building (RB) for energy analysis. We designed an RB for five non-residential buildings, using dynamic simulation from statistically analyzed data of building stock in South Korea. For modeling, four subsets of data—form, envelope, system, and operation—were assessed. This study uses the autosizing function within EnergyPlus, to develop the RB. The proposed approach allows for a flexible design where capacities and flow rates of the heating, ventilation, and air-conditioning (HVAC) system match the newly defined RB model. This approach would be ideal for closing the gap between the architectural data and equipment elements. The RB developed in this study allows for performing energy performance analysis by end-use. The analysis results by the end-use can provide support for country-level greenhouse gas (GHG)-mitigation-strategy development.

30 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
JJJaewan Joe
Jaewan Joe
JPJin hyung Park
Jin hyung Park
HCHeewon Choi
Heewon Choi
YPYooseok Park
Yooseok Park
JOJungwhan Oh
Jungwhan Oh
YKYounghoon Kwak
Younghoon Kwak
This study investigated the applicability of a tracking photovoltaic (PV) system installed in the roof area of a commercial building. Because PVWatts is the only PV module with a tracking feature in EnergyPlus, its electricity generation was validated through comparisons with detailed PV modules in EnergyPlus. The tracking PV system generated 26.8–35.5% more electricity annually than a fixed system in the climate of Incheon (S. Korea). The load coverage analysis of the tracking PV system was conducted with the reference commercial building model in EnergyPlus. Approximately 14% of the total building electric demand, including heating, ventilation, and air-conditioning; lighting; and equipment, was met by one PV array. Finally, the life cycle cost analysis of the tracking PV system was conducted by considering the net present value, which includes the initial installation and operation costs. The initial investment was returned after approximately 8 years, assuming between two and six tracking PV arrays were installed. Moreover, up to 26.8% cost savings were achieved in 15 years compared to the case without any PV arrays.