Ana Fernandes

Ms. Ana Fernandes


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2014 in Sensors
Verified
Journal Article
Open access
PDF file
AFAna Fernandes
Ana Fernandes
CDCarla Margarida Duarte
Carla Margarida Duarte
Filipe Arroyo CardosoFilipe Arroyo Cardoso
Filipe Arroyo Cardoso
RBRicardo Bexiga
Ricardo Bexiga
Susana Cardoso De FreitasSusana Cardoso De Freitas
Susana Cardoso De Freitas
PFPaulo Freitas*
Paulo Freitas*
Flow cytometers have been optimized for use in portable platforms, where cell separation, identification and counting can be achieved in a compact and modular format. This feature can be combined with magnetic detection, where magnetoresistive sensors can be integrated within microfluidic channels to detect magnetically labelled cells. This work describes a platform for in-flow detection of magnetically labelled cells with a magneto-resistive based cell cytometer. In particular, we present an example for the validation of the platform as a magnetic counter that identifies and quantifies Streptococcus agalactiae in milk.

1 March 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Hongyan BiHongyan Bi
Hongyan Bi
AFAna Fernandes
Ana Fernandes
Susana Cardoso De FreitasSusana Cardoso De Freitas
Susana Cardoso De Freitas
PFPaulo Freitas*
Paulo Freitas*

1 July 2018 in Biotechnology Advances
Verified
Journal Article
Open access
AFAna Fernandes
Ana Fernandes
Krist V. GernaeyKrist V. Gernaey
Krist V. Gernaey
UKUlrich Krühne
Ulrich Krühne
From its birth, microfluidics has been referenced as a revolutionary technology and the solution to long standing technological and sociological issues, such as detection of dilute compounds and personalized healthcare. Microfluidics has for example been envisioned as: (1) being capable of miniaturizing industrial production plants, thereby increasing their automation and operational safety at low cost; (2) being able to identify rare diseases by running bioanalytics directly on the patient's skin; (3) allowing health diagnostics in point-of-care sites through cheap lab-on-a-chip devices. However, the current state of microfluidics, although technologically advanced, has so far failed to reach the originally promised widespread use. In this paper, some of the aspects are identified and discussed that have prevented microfluidics from reaching its full potential, especially in the chemical engineering and biotechnology fields, focusing mainly on the specialization on a single target of most microfluidic devices and offering a perspective on the alternate, multi-use, "plug and play" approach. Increasing the flexibility of microfluidic platforms, by increasing their compatibility with different substrates, reactions and operation conditions, and other microfluidic systems is indeed of surmount importance and current academic and industrial approaches to modular microfluidics are presented. Furthermore, two views on the commercialization of plug-and-play microfluidics systems, leading towards improved acceptance and more widespread use, are introduced. A brief review of the main materials and fabrication strategies used in these fields, is also presented. Finally, a step-wise guide towards the development of microfluidic systems is introduced with special focus on the integration of sensors in microfluidics. The proposed guidelines are then applied for the development of two different example platforms, and to three examples taken from literature. With this work, we aim to provide an interesting perspective on the field of microfluidics when applied to chemical engineering and biotechnology studies, as well as to contribute with potential solutions to some of its current challenges.

1 December 2018 in New Biotechnology
Verified
Journal Article
Closed access
AFAna Fernandes
Ana Fernandes
DSDaria Semenova
Daria Semenova
PPPeter Panjan
Peter Panjan
ASAdama M. Sesay
Adama M. Sesay
Krist V. GernaeyKrist V. Gernaey
Krist V. Gernaey
UKUlrich Krühne
Ulrich Krühne

1 May 2020 in New Biotechnology
Verified
Journal Article
Closed access
DSDaria Semenova
Daria Semenova
AFAna Fernandes
Ana Fernandes
Juan M. BolivarJuan M. Bolivar
Juan M. Bolivar
IGInês P. Rosinha Grundtvig
Inês P. Rosinha Grundtvig
BVBarbara Vadot
Barbara Vadot
Krist V. GernaeyKrist V. Gernaey
Krist V. Gernaey

9 April 2018 in Bioengineering
Verified
Journal Article
Open access
PDF file
AFAna Fernandes
Ana Fernandes
JHJulia M. Halder
Julia M. Halder
BNBettina M. Nestl
Bettina M. Nestl
BHBernhard Hauer
Bernhard Hauer
Krist V. GernaeyKrist V. Gernaey
Krist V. Gernaey
UKUlrich Krühne
Ulrich Krühne
Selective oxidative functionalization of molecules is a highly relevant and often demanding reaction in organic chemistry. The use of biocatalysts allows the stereo- and regioselective introduction of oxygen molecules in organic compounds at milder conditions and avoids the use of complex group-protection schemes and toxic compounds usually applied in conventional organic chemistry. The identification of enzymes with the adequate properties for the target reaction and/or substrate requires better and faster screening strategies. In this manuscript, a microchannel with integrated oxygen sensors was applied to the screening of wild-type and site-directed mutated variants of naphthalene dioxygenase (NDO) from Pseudomonas sp. NICB 9816-4. The oxygen sensors were used to measure the oxygen consumption rate of several variants during the conversion of styrene to 1-phenylethanediol. The oxygen consumption rate allowed the distinguishing of endogenous respiration of the cell host from the oxygen consumed in the reaction. Furthermore, it was possible to identify the higher activity and different reaction rate of two variants, relative to the wild-type NDO. The meander microchannel with integrated oxygen sensors can therefore be used as a simple and fast screening platform for the selection of dioxygenase mutants, in terms of their ability to convert styrene, and potentially in terms of substrate specificity.