The virtual reality for maintainability (Revima) VR system supports maintainability simulation in aeronautics. Within this project we have developed and integrated a haptic device, the large haptic interface for aeronautic maintainability (LHIfAM). We use this device to track hand movements and provide force feedback within the large geometric models that describe aircraft engines. The user movements are the same as those that occur when testing physical mock-ups. An integrated haptic device and VR system for testing aircraft engines reduces development costs and avoids the necessity of physical mock-ups formaintainability.
30 July 2021 in International Journal of Computer Integrated Manufacturing
Aeronautics, in the context of industry 4.0, is continuously evolving to respond to the market dynamics and has incorporated automation to many stages of aircraft manufacturing. However, most of the final assembly line processes are still done manually and remain a challenge. Virtual Reality (VR) technologies can be leveraged to study the incorporation of automation systems involving Human-Robot Coexistence (HRC) in assembly processes before the physical system is available, which is beneficial for increasing the productivity and identifying issues beforehand, thus, preventing unexpected costs. In this context, a VR simulation environment was developed with two innovative factors: (1) The possibility to evaluate multiple new automated and semi-automated cabin and cargo processes and select the best one in terms of specific Key Performance Indicators (KPIs) for a future implementation in the physical system and (2) the capability to study the ergonomics of the human worker inside the narrow space of the fuselage while assembling the parts and coexisting with robots, without compromising the worker’s safety. The results show that most of the new proposed strategies improve the assembly time, worker cost, or ergonomics of the process, with an investment varying between 100 K and 200 K euros and ROI of 1–2 years.
Virtual reality (VR)- and augmented reality (AR)-based simulations are key technologies in Industry 4.0 which allow for testing and studying of new processes before their deployment. A simulator of industrial processes needs a flexible way in which to model the activities performed by the worker and other elements involved, such as robots and machinery. This work proposes a framework to model industrial processes for VR and AR simulators. The desk method was used to review previous research and extract the most important features of current approaches. Novel features include interaction among human workers and a variety of automation systems, such as collaborative robots, a broader set of tasks (including assembly and disassembly of components), flexibility of modeling industrial processes for different domains and purposes, a clear separation of process definition and simulator, and independence of specific programming languages or technologies. Three industrial scenarios modeled with this framework are presented: an aircraft assembly scenario, a guidance tool for high-voltage cell security, and an application for the training of machine-tool usage.
The method of drug delivery directly into the cochlea with an implantable pump connected to a CI electrode array ensures long-term delivery and effective dose control, and also provides the possibility to use different drugs. The objective is to develop a model of inner ear pharmacokinetics of an implanted cochlea, with the delivery of FITC-Dextran, in the non-human primate model. A preclinical cochlear electrode array (CI Electrode Array HL14DD, manufactured by Cochlear Ltd.) attached to an implantable peristaltic pump filled with FITC-Dextran was implanted unilaterally in a total of 15 Macaca fascicularis (Mf). Three groups were created (5 Mf in each group), according to three different drug delivery times: 2 hours, 24 hours and 7 days. Perilymph (10 samples, 1μL each) was sampled from the apex of the cochlea and measured immediately after extraction with a spectrofluorometer. After scarifying the specimens, x-Rays and histological analysis were performed. Surgery, sampling and histological analysis were performed successfully in all specimens. FITC-Dextran quantification showed different patterns, depending on the delivery group. In the 2 hours injection experiment, an increase in FITC-Dextran concentrations over the sample collection time was seen, reaching maximum concentration peaks (420-964µM) between samples 5 and 7, decreasing in successive samples, without returning to baseline. The 24-hours and 7-days injection experiments showed even behaviour throughout the 10 samples obtained, reaching a plateau with mean concentrations ranging from 2144 to 2564 µM and from 1409 to 2502µM, respectively. Statistically significant differences between the 2 hours and 24 hours groups (p = 0.001) and between the 2 hours and 7 days groups (p = 0.037) were observed, while between the 24 hours and 7 days groups no statistical differences were found. This experimental study shows that a model of drug delivery and pharmacokinetics using an active pump connected to an electrode array is feasible in Mf. An infusion time ranging from 2 to 24 hours is required to reach a maximum concentration peak at the apex. It establishes then an even concentration profile from base to apex that is maintained throughout the infusion time in Mf. Flow mechanisms during injection and during sampling that may explain such findings may involve cochlear aqueduct flow as well as the possible existence of substance exchange from scala tympani to extracellular spaces, such as the modiolar space or the endolymphatic sinus, acting as a substance reservoir to maintain a relatively flat concentration profile from base to apex during sampling. Leveraging the learnings achieved by experimentation in rodent models, we can move to experiment in non-human primate with the aim of achieving a useful model that provides transferrable data to human pharmacokinetics. Thus, it may broaden clinical and therapeutic approaches to inner ear diseases.
27 July 2022 in IEEE Transactions on Intelligent Transportation Systems
The future of autonomous driving is slowly approaching, but there are still many steps to take before it can become a reality. It is crucial to pay attention to road infrastructure, because without it, intelligent vehicles will not be able to operate reliably, and it will never be possible to dispense of driver’s control. This paper presents the work carried out for the detection of road markings damage using computer vision techniques. This is a complex task for which there are currently not many papers and large image sets in the literature. This study uses images from the public Road Damage Detection dataset for the D44 defect and also provides 971 new labelled images for Spanish roads. For this purpose, three detectors based on deep learning architectures (Faster RCNN, SDD and EfficientDet) have been used and single-source and mixed-source models have been studied to find the model that best fits the target images. Finally, F1-score values reaching 0.929 and 0.934 have been obtained for Japanese and Spanish images respectively which improve the state-of-the-art results by 25%. It can be concluded that the results of this study are promising, although the collection of many more images will be necessary for the scientific community to continue advancing in the future in this field of research.