Zofia Iskierko

Dr. Zofia Iskierko

Institute of Physical Chemistry Polish Academy of Sciences
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Biotechnology Advances
Verified
Journal Article
Closed access
ZIZofia Iskierko
Zofia Iskierko
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
KBKatarzyna Bartold
Katarzyna Bartold
APAgnieszka Pietrzyk-Le
Agnieszka Pietrzyk-Le
Krzysztof NoworytaKrzysztof Noworyta
Krzysztof Noworyta
WKWlodzimierz Kutner
Wlodzimierz Kutner

1 January 2015 in Electrochemistry Communications
Verified
Journal Article
Closed access
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
ZIZofia Iskierko
Zofia Iskierko
APAgnieszka Pietrzyk-Le
Agnieszka Pietrzyk-Le
FDFrancis D'SOuza
Francis D'SOuza
WKWlodzimierz Kutner
Wlodzimierz Kutner

1 August 2016 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
ZIZofia Iskierko
Zofia Iskierko
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
DPDaniel Prochowicz
Daniel Prochowicz
KFKrzysztof Fronc
Krzysztof Fronc
FDFrancis D’sOuza
Francis D’sOuza
Krzysztof NoworytaKrzysztof Noworyta
Krzysztof Noworyta

15 December 2016 in Journal of Materials Chemistry C
Verified
Journal Article
Open access
PDF file
ZIZofia Iskierko
Zofia Iskierko
ACA. Checinska
A. Checinska
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
KGK. Golebiewska
K. Golebiewska
Krzysztof NoworytaKrzysztof Noworyta
Krzysztof Noworyta
WKWlodzimierz Kutner
Wlodzimierz Kutner
Chemosensing systems were devised for the enantioselective determination ofd- andl-phenylalanine (d- andl-Phe).

22 March 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
KBKatarzyna Bartold
Katarzyna Bartold
ZIZofia Iskierko
Zofia Iskierko
PBPawel Borowicz
Pawel Borowicz
Krzysztof NoworytaKrzysztof Noworyta
Krzysztof Noworyta
CLChu-Yun Lin
Chu-Yun Lin
WKWlodzimierz Kutner
Wlodzimierz Kutner
A conducting molecularly imprinted polymer (MIP) film was integrated with an extended-gate field-effect transistor (EG-FET) transducer to determine epitopes of matrix metalloproteinase-1 (MMP-1) protein biomarker of idiopathic pulmonary fibrosis (IPF) selectively. Most suitable epitopes for imprinting were selected with Basic Local Alignment Search Tool software. From a pool of MMP-1 epitopes, the two, i.e., MIAHDFPGIGHK and HGYPKDIYSS, the relatively short ones, most promising for MMP-1 determination, were selected, mainly considering their advantageous outermost location in the protein molecule and stability against aggregation. MIPs templated with selected epitopes of the MMP-1 protein were successfully prepared by potentiodynamic electropolymerization and simultaneously deposited as thin films on electrodes. The chemosensors, constructed of MIP films integrated with EG-FET, proved useful in determining these epitopes even in a medium as complex as a control serum. The limit of detection for the MIAHDFPGIGHK and HGYPKDIYSS epitope was ∼60 and 20 nM, respectively. Moreover, the chemosensors selectively recognized whole MMP-1 protein in the 50-500 nM concentration range in buffered control serum samples.

1 February 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
ZIZofia Iskierko
Zofia Iskierko
Krzysztof NoworytaKrzysztof Noworyta
Krzysztof Noworyta
MCMaciej Cieplak
Maciej Cieplak
PBPaweł Borowicz Paweł Borowicz
Paweł Borowicz Paweł Borowicz
WKWlodzimierz Kutner
Wlodzimierz Kutner