Vladislav Toronov

Dr. Vladislav Toronov

Department of Physics, Toronto Metropolitan University, Toronto, ON M5B 2K3, Canada

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2010 in Applied Optics
Verified
Journal Article
Closed access
PDF file
OPOlivia Pucci
Olivia Pucci
Vladislav ToronovVladislav Toronov
Vladislav Toronov
KLKeith St. Lawrence
Keith St. Lawrence
We present the development of a continuous-wave method of quantifying the optical properties of a two-layered model of the human head using a broadband spectral approach. Absolute absorption and scattering properties of the upper and lower layers of phantoms with known optical properties were reconstructed from steady-state multi-distance measurements by performing differential fit analysis of the near-infrared reflectance spectrum between 700 and 1000nm. From spectra acquired at 10, 20, and 30mm, the concentration of a chromophore in the bottom layer was determined within an error of 10% in the presence of a 15mm thick top layer. These results demonstrate that our method was able to determine the optical properties of the lower layer, which represents brain, with acceptable error at specific source–detector distances.

9 December 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
ISIrina Schelkanova
Irina Schelkanova
Vladislav ToronovVladislav Toronov
Vladislav Toronov
The goal of this study was to investigate the ability of independent component analysis in the time-spectral domain to isolate physiological sources of functional near infrared spectroscopy signals. We apply independent component analysis to the broadband fNIRS data acquired on the human forehead at 650 different wavelengths between 700 nm and 950 nm. To induce cerebral oxygenation changes we use the breath holding paradigm. We found one major independent component during baseline and two major components during exercise. Each independent component corresponds to one oxy-hemoglobin and one deoxy-hemoglobin time courses. The corresponding characteristic spectra of changes in optical absorption suggested that one component represented vasodilation of cerebral arterioles while the delayed component represented the washout of deoxyhemoglobin either in cerebral capillaries and venules or in extra cerebral tissue. We found that both broadband and isolated wavelength data can produce similar independent components.

27 August 2010 in Optics Express
Verified
Journal Article
Closed access
PDF file
ISIrina Schelkanova
Irina Schelkanova
Vladislav ToronovVladislav Toronov
Vladislav Toronov
We have compared cerebral hemodynamic changes measured by near-infrared spectroscopy (NIRS) with simultaneously acquired BOLD fMRI signals during breath hold challenge in humans. The oxy- and deoxyhemoglobin concentration changes were obtained from the same broadband NIRS data using four different quantitation methods. One method used only two wavelengths (690 nm and 830 nm), and three other methods used broadband data with different spectral fitting algorithms. We found that the broadband techniques employing spectral derivatives were significantly superior to the multi-wavelength methods in terms of the correlation with the BOLD signals. In two cases out of six we found that the time courses of the deoxyhemoglobin changes produced by the two-wavelength method were qualitatively inconsistent with the BOLD fMRI signals.

14 November 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NSNima Soltani
Nima Soltani
OROlivia Rennie
Olivia Rennie
RMRohit Mohindra
Rohit Mohindra
SLSteve Lin
Steve Lin
Vladislav ToronovVladislav Toronov
Vladislav Toronov
Hemodynamic models provide a mathematical representation and computational framework that describe the changes in blood flow, blood volume, and oxygenation levels that occur in response to neural activity and systemic changes, while near-infrared spectroscopy (NIRS) measures deoxyhemoglobin, oxyhemoglobin, and other chromophores to analyze cerebral hemodynamics and metabolism. In this study, we apply a dynamic hemometabolic model to NIRS data acquired during cardiac arrest and cardiopulmonary resuscitation (CPR) in pigs. Our goals were to test the model’s ability to accurately describe the observed phenomena, to gain an understanding of the intricate behavior of cerebral microvasculature, and to compare the obtained parameters with known values. By employing the inverse of the hemometabolic model, we measured a range of significant physiological parameters, such as the rate of oxygen diffusion from blood to tissue, the arteriole and venule volume fractions, and the Fåhraeus factor. Statistical analysis uncovered significant differences in the baseline and post-cardiac arrest values of some of the parameters.

28 October 2013 in The European Physical Journal Special Topics
Verified
Journal Article
Closed access
PDF file
Vladislav ToronovVladislav Toronov
Vladislav Toronov
TMT. Myllylä
T. Myllylä
VKV. Kiviniemi
V. Kiviniemi
Valery TuchinValery Tuchin
Valery Tuchin

31 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZGZahida Guerouah
Zahida Guerouah
SLSteve Lin
Steve Lin
Vladislav ToronovVladislav Toronov
Vladislav Toronov
A major limitation of near-infrared spectroscopy (NIRS) is its high sensitivity to the scalp and low sensitivity to the brain of adult humans. In the present work we used multi-distance hyperspectral NIRS (hNIRS) to investigate the optimal source-detector distances, wavelength ranges, and analysis techniques to separate cerebral responses to 30 s breath-holds (BHs) from the responses in the superficial tissue layer in healthy adult humans. We observed significant responses to BHs in the scalp hemodynamics. Cerebral responses to BHs were detected in the cytochrome C oxidase redox (rCCO) at 4 cm without using data from the short-distance channel. Using the data from the 1 cm channel in the two-layer regression algorithm showed that cerebral hemodynamic and rCCO responses also occurred at 3 cm. We found that the waveband 700–900 nm was optimal for the detection of cerebral responses to BHs in adults.