The goal of this study was to investigate the ability of independent component analysis in the time-spectral domain to isolate physiological sources of functional near infrared spectroscopy signals. We apply independent component analysis to the broadband fNIRS data acquired on the human forehead at 650 different wavelengths between 700 nm and 950 nm. To induce cerebral oxygenation changes we use the breath holding paradigm. We found one major independent component during baseline and two major components during exercise. Each independent component corresponds to one oxy-hemoglobin and one deoxy-hemoglobin time courses. The corresponding characteristic spectra of changes in optical absorption suggested that one component represented vasodilation of cerebral arterioles while the delayed component represented the washout of deoxyhemoglobin either in cerebral capillaries and venules or in extra cerebral tissue. We found that both broadband and isolated wavelength data can produce similar independent components.
14 November 2013 in IEEE Journal of Selected Topics in Quantum Electronics
We performed a large scale Monte Carlo verification of possibility of detecting the capillary grid spatial pattern in surface tissues such as mucosal epithelium or epidermis with very thin (optically nonsignificant) stratum corneum by a spatially resolved diffuse reflectance probe. Our results confirm the hypothesis that a spatially resolved, steady-state, diffuse reflectance spectroscopy can potentially identify absorption inhomogeneities located at the depth of 0.5-1.0 of the transport mean free path l s ' = 1/μ s ', which is the range of capillary loops locations within epithelium. The modulation depth depends significantly on an inhomogeneity's absorption, depth of the inhomogeneity, a bulk reduced scattering coefficient, and the size of the defect. The optical clearing technique can be used to lower the scattering in surface tissues and subsequently increase the transport mean free path, which can lead to increase in the sensitivity of the method.
We have compared cerebral hemodynamic changes measured by near-infrared spectroscopy (NIRS) with simultaneously acquired BOLD fMRI signals during breath hold challenge in humans. The oxy- and deoxyhemoglobin concentration changes were obtained from the same broadband NIRS data using four different quantitation methods. One method used only two wavelengths (690 nm and 830 nm), and three other methods used broadband data with different spectral fitting algorithms. We found that the broadband techniques employing spectral derivatives were significantly superior to the multi-wavelength methods in terms of the correlation with the BOLD signals. In two cases out of six we found that the time courses of the deoxyhemoglobin changes produced by the two-wavelength method were qualitatively inconsistent with the BOLD fMRI signals.
Experimental research into changes of the optical thickness of phenanthrenequinone-doped polymethyl methacrylate samples in the process of irradiation by a 473 nm laser is presented. It was demonstrated that heating-induced reversible changes lead to a decrease in the optical thickness. The temperature coefficient of the relative changes of the optical thickness was measured to be , which matches the data published by other authors. It is also established that the irreversible changes induced by the photochemical transformation lead to an increase in the optical thickness outside of the absorption band of the samples (), where the relative change of which at is . It was demonstrated that the reversible and irreversible changes do not compensate for each other in the process of sample exposure.
27 October 2014 in Journal of Physics: Conference Series