Munsif Jatoi

Dr. Munsif Jatoi


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2021 in Optimal Control Applications and Methods
Verified
Journal Article
Closed access
PDF file
Muhammad Suhail ShaikhMuhammad Suhail Shaikh
Muhammad Suhail Shaikh
CHChangchun Hua
Changchun Hua
MHMANNAN HASSAN
MANNAN HASSAN
SRSAURAV RAJ
SAURAV RAJ
MJMunsif Jatoi
Munsif Jatoi
MAMuhammad Mohsin Ansari
Muhammad Mohsin Ansari

1 November 2018 in Signal, Image and Video Processing
Verified
Journal Article
Closed access
PDF file
MJMunsif Jatoi
Munsif Jatoi
NKNidal Kamel
Nidal Kamel

1 March 2016 in International Journal of Imaging Systems and Technology
Verified
Journal Article
Closed access
PDF file
MJMunsif Jatoi
Munsif Jatoi
NKNidal Kamel
Nidal Kamel
AMAamir Saeed Malik
Aamir Saeed Malik
IFIbrahima Faye
Ibrahima Faye
JBJose Miguel Sanchez Bornot
Jose Miguel Sanchez Bornot
TBTahamina Begum
Tahamina Begum

5 March 2021 in Current Medical Imaging
Verified
Journal Article
Closed access
PDF file
MJMunsif Jatoi
Munsif Jatoi
FDFayaz Ali Dharejo
Fayaz Ali Dharejo
Sadam HussainSadam Hussain
Sadam Hussain
Background: The brain is the most complex organ of the human body with millions of connections and activations. The electromagnetic signals are generated inside the brain due to a mental or physical task performed. These signals excite a bunch of neurons within a particular lobe depending upon the nature of the task performed. To localize this activity, certain machine learning (ML) techniques in conjunction with a neuroimaging technique (M/EEG, fMRI, PET) are developed. Different ML techniques are provided in the literature for brain source localization. Among them, the most common are: minimum norm estimation (MNE), low resolution brain electromagnetic tomography (LORETA) and Bayesian framework based multiple sparse priors (MSP). Aims: In this research work, EEG is used as a neuroimaging technique. Methods: EEG data is synthetically generated at SNR=5dB. Afterwards, ML techniques are applied to estimate the active sources. Each dataset is run for multiple trials (>40). The performance is analyzed using free energy and localization error as performance indicators. Furthermore, MSP is applied with a variant number of patches to observe the impact of patches on source localization. Results: It is observed that with an increased number of patches, the sources are localized with more precision and accuracy as expressed in terms of free energy and localization error, respectively. Conclusion: The patches optimization within the Bayesian Framework produces improved results in terms of free energy and localization error.

16 October 2019 in International Journal of Imaging Systems and Technology
Verified
Journal Article
Closed access
PDF file
MJMunsif Jatoi
Munsif Jatoi
NKNidal Kamel
Nidal Kamel
JLJosé D. López
José D. López

10 January 2019 in Current Medical Imaging
Verified
Journal Article
Closed access
MJMunsif Jatoi
Munsif Jatoi
NKNidal Kamel
Nidal Kamel
SMSayed Hyder Abbas Musavi
Sayed Hyder Abbas Musavi
JLJosé David López
José David López
Background: Electrical signals are generated inside human brain due to any mental or physical task. This causes activation of several sources inside brain which are localized using various optimization algorithms. Methods: Such activity is recorded through various neuroimaging techniques like fMRI, EEG, MEG etc. EEG signals based localization is termed as EEG source localization. The source localization problem is defined by two complementary problems; the forward problem and the inverse problem. The forward problem involves the modeling how the electromagnetic sources cause measurement in sensor space, while the inverse problem refers to the estimation of the sources (causes) from observed data (consequences). Usually, this inverse problem is ill-posed. In other words, there are many solutions to the inverse problem that explains the same data. This ill-posed problem can be finessed by using prior information within a Bayesian framework. This research work discusses source reconstruction for EEG data using a Bayesian framework. In particular, MSP, LORETA and MNE are compared. Results: The results are compared in terms of variational free energy approximation to model evidence and in terms of variance accounted for in the sensor space. The results are taken for real time EEG data and synthetically generated EEG data at an SNR level of 10dB. Conclusion: In brief, it was seen that MSP has the highest evidence and lowest localization error when compared to classical models. Furthermore, the plausibility and consistency of the source reconstruction speaks to the ability of MSP technique to localize active brain sources.