Zhe Yu

Prof. Zhe Yu


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2010 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
SLStéphanie P. Lacour
Stéphanie P. Lacour
SBSamia Benmerah
Samia Benmerah
ETEdward Tarte
Edward Tarte
JFJames FitzGerald
James FitzGerald
JSJordi Serra
Jordi Serra
BMBarclay Morrison
Barclay Morrison

4 September 2017 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
DQDianpeng Qi
Dianpeng Qi
ZLZhiyuan Liu
Zhiyuan Liu
YLYan Liu
Yan Liu
YJYing Jiang
Ying Jiang
WLWan Ru Leow
Wan Ru Leow
XCXiaodong Chen
Xiaodong Chen

10 April 2015 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
DQDianpeng Qi
Dianpeng Qi
ZLZhiyuan Liu
Zhiyuan Liu
MYMei Yu
Mei Yu
YLYan Liu
Yan Liu
YTYuxin Tang
Yuxin Tang
XCXiaodong Chen
Xiaodong Chen

30 June 2007 in Nano Letters
Verified
Journal Article
Closed access
ZYZhe Yu
Zhe Yu
TMTimothy E. McKnight
Timothy E. McKnight
MEM. Nance Ericson
M. Nance Ericson
AMAnatoli V. Melechko
Anatoli V. Melechko
MSMichael L. Simpson
Michael L. Simpson
BMBarclay Morrison
Barclay Morrison

1 July 2009 in Journal of Neurotrauma
Verified
Journal Article
Closed access
ZYZhe Yu
Zhe Yu
OGOliver Graudejus
Oliver Graudejus
CTCandice Tsay
Candice Tsay
SLStéphanie P. Lacour
Stéphanie P. Lacour
SWSigurd Wagner
Sigurd Wagner
BMBarclay Morrison
Barclay Morrison
Interfacing electronics and recording electrophysiological activity in mechanically active biological tissues is challenging. This challenge extends to recording neural function of brain tissue in the setting of traumatic brain injury (TBI), which is caused by rapid (within hundreds of milliseconds) and large (greater than 5% strain) brain deformation. Interfacing electrodes must be biocompatible on multiple levels and should deform with the tissue to prevent additional mechanical damage. We describe an elastically stretchable microelectrode array (SMEA) that is capable of undergoing large, biaxial, 2-D stretch while remaining functional. The new SMEA consists of elastically stretchable thin metal films on a silicone membrane. It can stimulate and detect electrical activity from cultured brain tissue (hippocampal slices), before, during, and after large biaxial deformation. We have incorporated the SMEA into a well-characterized in vitro TBI research platform, which reproduces the biomechanics of TBI by stretching the SMEA and the adherent brain slice culture. Mechanical injury parameters, such as strain and strain rate, can be precisely controlled to generate specific levels of damage. The SMEA allowed for quantification of neuronal function both before and after injury, without breaking culture sterility or repositioning the electrodes for the injury event, thus enabling serial and long-term measurements. We report tests of the SMEA and an initial application to study the effect of mechanical stimuli on neuron function, which could be employed as a high-content, drug-screening platform for TBI.

1 January 2009 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
OGO. Graudejus
O. Graudejus
ZYZhe Yu
Zhe Yu
JJJ. Jones
J. Jones
BMB. Morrison
B. Morrison
SWS. Wagner
S. Wagner
Elastically stretchable microelectrode arrays (SMEAs) were fabricated, and their functionality was tested by recording field potentials from neural tissue. The SMEA includes 11 microelectrodes, each with a recording area of <mml:math display="inline"><mml:mrow><mml:mn>100</mml:mn><mml:mo>×</mml:mo><mml:mn>200</mml:mn><mml:mspace width="0.3em"></mml:mspace><mml:mi>μ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math>100×200μm and a reference electrode. The microelectrodes were fabricated by depositing and patterning thin-film gold conductors on the elastomeric substrate poly(dimethylsiloxane). A photopatternable silicone was used to encapsulate the microelectrodes and pattern vias for electrical contact. The recording sites of the microelectrodes were electroplated with platinum black to reduce the impedance of the electrode/electrolyte interface. Spontaneous and stimulus-evoked activity was recorded from hippocampal slices placed on an array that was biaxially stretched up to 13.3%. No appreciable difference in microelectrode properties was detected before and after stretching, demonstrating that the microelectrodes can be stretched reversibly.