The present work investigated the effect of Polylactic acid (PLA) fibers produced by centrifugal spinning with incorporated BaTiO3 particles to improve their bacteriostatic behavior. The PLA matrix and three composites, presenting three different amounts of fillers, were subjected to UV/O3 treatment monitoring the possible modifications that occurred over time. The morphological and physical properties of the surfaces were characterized by different microscopic techniques, contact angle, and surface potential measurements. Subsequently, the samples were tested in vitro with human dermal fibroblasts (HDF) to verify the cytotoxicity of the substrates. No significant differences between the PLA matrix and composites emerged; the high hydrophobicity of the fibers, derived by the polymer structure, represented an obstacle limiting the fibroblast attachment. Samples underwent bacterial exposure (Staphylococcus epidermidis) for 12 and 24 h. Increasing the concentration of BT, the number of living bacteria and their distribution decreased in comparison with the PLA matrix suggesting an effect of the inorganic filler, which generates a neutralization effect leading to reactive oxygen species (ROS) generation and subsequently to bacterial damages. These results suggest that the barium titanate (BT) fillers clearly improve the antibacterial properties of PLA fibers after aging tests made before bacterial exposure, representing a potential candidate in the creation of composites for medical applications.
Functional coatings are commonly applied to biomaterials in order to improve their properties. In this work, polyethylene was coated with a silicon nitride (Si3N4) powder using a pulsed laser source in a nitrogen gas atmosphere. Several analytical techniques were used to characterize the functionalized surface of the polymer, including Raman spectroscopy, laser microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Antibacterial properties were tested in vitro against Staphylococcus epidermidis. The Si3N4 coating sensibly reduced the amount of living bacteria when compared to the uncoated polymer. Osteoconductivity was also tested in vitro using SaOS-2 osteosarcoma cells. The presence of Si3N4 coating resulted in an increased amount of hydroxyapatite. Coating of polyethylene with silicon nitride may lead to improved performance of indwelling orthopaedic or less invasive medical devices.
Tooth loss impairs mastication, deglutition and esthetics and affects systemic health through nutritional deficiency, weight loss, muscle weakness, delayed wound healing, and bone fragility. Approximately 90% of tooth loss is due to dental caries and periodontal disease. Accordingly, early treatment of dental caries is essential to maintaining quality of life. To date, the clinical diagnosis of dental caries has been based on each dentist’s subjective assessment, but this visual method lacks objectivity. To improve diagnostic ability, highly sensitive quantitative methods have been developed for the diagnosis and prevention of dental caries and are gradually becoming a mandatory item in modern dentistry. High-resolution Raman spectroscopy is a suitable tool for recognizing the subtle structural changes that occur in dental enamel in already developed or, more importantly, incipient dental caries. Raman analysis could soon emerge as a breakthrough in dentistry because of its high diagnostic sensitivity. In this study, we build upon our previous findings in a new analysis of dental caries using Raman spectroscopy imaging and discuss the possibility of using Raman photonic imaging in support of objective diagnostics in dentistry. Our findings support the Raman method of caries detection in comparison with other conventional or new approaches.
22 February 2020 in International Journal of Polymeric Materials and Polymeric Biomaterials
Polyvinyl-siloxane (PVS) is a modified condensation silicon that has found applications in the field of dental impression materials thanks to its high biocompatibility and the ability to be modeled on solid surfaces with a micrometric resolution. Major concerns have been raised on the possibility to sterilize PVS without distorting its geometrical shape, as immersion in antibacterial solutions often results in swelling. As a possible alternative, both radiofrequency glow discharge and UV sterilization have been successfully applied. In this paper, we focus on the possible use of a cheap, bio-compatible ceramic reinforcement powder (BaTiO3) to obtain a higher resistance to colonization and contribute to the prevention of bacterial infections, not only for temporary applications but also long-term. We also use a vacuum treatment to transform the composite polymer into soft scaffolds with relative densities between 35 and 65%) with similar biological properties. Testing with fractions of ceramic reinforcement up to 25% has clearly shown a beneficial effect in terms of bacteria viability against Staphylococcus epidermidis, with potential for future applications as soft biomedical scaffolds, medical clothing, sanitary materials, and filters for the sterilization of air and water.
The use of Type IV cylinders for gas storage is becoming more widespread in various sectors, especially in transportation, owing to the lightweight nature of this type of cylinder, which is composed of a polymeric liner that exerts a barrier effect and an outer composite material shell that primarily imparts mechanical strength. In this work, the failure analysis of an HDPE liner in a Type IV cylinder for high-pressure storage was carried out. The breakdown occurred during a cyclic pressure test at room temperature and manifested in the hemispherical head area, as cracks perpendicular to the liner pinch-off line. The failed sample was thoroughly investigated and its characteristics were compared with those of other liners at different stages of production of a Type IV cylinder (blow molding, curing of the composite material). An examination of the liner showed that no significant chemical and morphological changes occurred during the production cycle of a Type IV cylinder that could justify the liner rupture, and that the most likely cause of failure was a design-related fatigue phenomenon.