Michael Hubbard

Dr. Michael Hubbard

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MLMatthew Lowdon
Matthew Lowdon
Peter MartinPeter Martin
Peter Martin
MHMichael Hubbard
Michael Hubbard
MTMatt Taggart
Matt Taggart
DCDean Connor
Dean Connor
TSThomas Bligh Scott
Thomas Bligh Scott
In response to the Fukushima Daiichi Nuclear Power Plant accident, there has occurred the unabated growth in the number of airborne platforms developed to perform radiation mapping—each utilising various designs of a low-altitude uncrewed aerial vehicle. Alongside the associated advancements in the airborne system transporting the radiation detection payload, from the earliest radiological analyses performed using gas-filled Geiger-Muller tube detectors, modern radiation detection and mapping platforms are now based near-exclusively on solid-state scintillator detectors. With numerous varieties of such light-emitting crystalline materials now in existence, this combined desk and computational modelling study sought to evaluate the best-available detector material compatible with the requirements for low-altitude autonomous radiation detection, localisation and subsequent high spatial-resolution mapping of both naturally occurring and anthropogenically-derived radionuclides. The ideal geometry of such detector materials is also evaluated. While NaI and CsI (both elementally doped) are (and will likely remain) the mainstays of radiation detection, LaBr3 scintillation detectors were determined to possess not only a greater sensitivity to incident gamma-ray radiation, but also a far superior spectral (energy) resolution over existing and other potentially deployable detector materials. Combined with their current competitive cost, an array of three such composition cylindrical detectors were determined to provide the best means of detecting and discriminating the various incident gamma-rays.

1 July 2021 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Open access
PDF file
TETanja Eraerds
Tanja Eraerds
VAValeria Antonelli
Valeria Antonelli
CDChris Davis
Chris Davis
DHDavid J. Hall
David J. Hall
OHOliver Hetherington
Oliver Hetherington
ARArne Rau
Arne Rau
A comprehensive description of the Wide Field Imager (WFI) instrument is provided in Ref. 1. Here, we give a short summary of the main relevant components. This work is an update of Ref. 2 and hence contains similar descriptions of the WFI, key science drivers, background components, and the Monte Carlo simulation tool Geant4/GRAS.3,4 The WFI will provide important scientific capabilities to the mission. The large detector array (LDA) will offer an unprecedented survey capability with its 40′×40′ field of view (FOV) properly sampling the point spread function (5″ HEW on-axis) provided by the Athena mirror system.

21 March 2019 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MHMichael Hubbard
Michael Hubbard
MTM.P. Taggart
M.P. Taggart
PSPaul Sellin
Paul Sellin

1 January 2022 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Open access
PDF file
EMEric D. Miller
Eric D. Miller
CGCatherine E. Grant
Catherine E. Grant
MBMarshall W. Bautz
Marshall W. Bautz
SMSilvano Molendi
Silvano Molendi
RKRalph P. Kraft
Ralph P. Kraft
DWDan R. Wilkins
Dan R. Wilkins
The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. Among Athena’s ambitious science programs are observations of faint, diffuse sources limited by statistical and systematic uncertainty in the background produced by high-energy cosmic ray particles. These particles produce easily identified “cosmic-ray tracks” along with less easily identified signals produced by secondary photons or x-rays generated by particle interactions with the instrument. Such secondaries produce identical signals to the x-rays focused by the optics and cannot be filtered without also eliminating these precious photons. As part of a larger effort to estimate the level of unrejected background and mitigate its effects, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background signal, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a realistic WFI observation containing only particle background. The technique under study, self-anti-coincidence (SAC), then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated x-ray imaging detector and could allow the WFI and similar instruments to probe to truly faint x-ray surface brightness.

1 August 2019 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
MTMatt Taggart
Matt Taggart
ACA. Charoupa
A. Charoupa
MHMichael Hubbard
Michael Hubbard
SJS.M. Jafari
S.M. Jafari
ALAnnika Lohstroh
Annika Lohstroh
MSM. Stroud
M. Stroud

18 November 2025 in Space Science Reviews
Verified
Journal Article
Open access
PDF file
SSS. Sembay
S. Sembay
ACA. Cheney
A. Cheney
RHR. Hampson
R. Hampson
DAD. Agnolon
D. Agnolon
TAT. Arnold
T. Arnold
SYS. Yang
S. Yang
The Soft X-ray Imager (SXI) is a compact X-ray telescope with a wide $15.5^{\circ } \times 26.5^{\circ }$ 15.5 ∘ × 26.5 ∘ field-of-view (FOV) and is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer (SMILE) mission. SMILE is a joint science mission between the European Space Agency (ESA) and the Chinese Academy of Sciences (CAS) and is due for launch in 2026. SXI is capable of viewing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit. SXI is designed to detect the soft X-rays from the Solar Wind Charge eXchange (SWCX) process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere. SWCX provides a mechanism for boundary detection within the magnetosphere, such as the position of Earth’s magnetopause, because the solar wind heavy ions essentially do not enter regions of closed magnetic field lines. The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours. The SXI has a large grasp (FOV times effective area) and a CCD-based detector system with an energy resolution comparable to contemporary X-ray astrophysics missions. SXI will, therefore, acquire high precision spectra capable of discriminating the composition of many of the solar wind heavy ions within the regions of interest. SXI is led by the University of Leicester (UL) in the United Kingdom (UK) with collaborating organisations on hardware, software and science support within the UK, Europe, China and the United States.