Mirosław Szyłak-Szydłowski

Dr. Mirosław Szyłak-Szydłowski

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in International Biodeterioration & Biodegradation
Verified
Journal Article
Closed access
MSMirosław Szyłak-Szydłowski
Mirosław Szyłak-Szydłowski
AKAndrzej KULIG
Andrzej KULIG
EMEwa Miaśkiewicz-Pęska
Ewa Miaśkiewicz-Pęska

22 November 2022 in Building and Environment
Verified
Journal Article
Closed access
PUPiotr Uścinowicz
Piotr Uścinowicz
ABAnna Bogdan
Anna Bogdan
MSMirosław Szyłak-Szydłowski
Mirosław Szyłak-Szydłowski
Magdalena MłynarczykMagdalena Młynarczyk
Magdalena Młynarczyk
DĆDominika Ćwiklińska
Dominika Ćwiklińska

30 June 2015 in Water, Air, & Soil Pollution
Verified
Journal Article
Open access
PDF file
MSMirosław Szyłak-Szydłowski
Mirosław Szyłak-Szydłowski
In indirect olfactometry analysis, to avoid condensation or adsorption processes during or storage of the sample, containers made of suitable materials should be used. Also, reaction between the chemicals during transport from the source of the odour to the research laboratory is an important process which can influence on examinations’ results. Study included determination of the odour and compound concentrations of six gas mixtures. Gas samples were collected by silicone hoses into Tedlar® bags and tested by Nasal Ranger, SM-100 olfactometers and Photovac Voyager gas chromatograph. Time of keeping gas in bags was 78 h, and concentration of compounds was measured every hour, eight times per day. For benzene, acetone, 1,1-dichloroethylene, c-1,2-dichloroethylene, t-1,2-dichloroethylene, methyl ethyl ketone and vinyl chloride, 100 % decrease of concentration has been noticed within 78 h of holding in the bag. Average rate of loss of most compounds concentration was from 0.01 to 2.50 % for the first 30 h and from 0.35 to 18.50 % during the last 48 h of examination. Decreasing of odour concentration measured by Nasal Ranger (NR) in all series was between 0.00 and 4.98 % till 30 h, between 1.91 and 100 % in the last 48 h of test and between 1.61 and 100 % in 78 h. In case of odour concentration measured by SM, those values were, respectively, 1.26–4.93 %, 1.39–4.93 % and 2.40–3.18 %. Values of average rate of intensity decreasing were, respectively, 0.77–1.75 %, 2.36–4.67 % and 1.18–2.07 %. Statistically significant correlation coefficients for compound concentrations and intensity, odour concentration obtained by SM-100 as well as NR were, respectively, 0.55–0.97, 0.47–0.99 and 0.37–0.98.

12 November 2019 in Water
Verified
Journal Article
Open access
PDF file
AKAndrzej KULIG
Andrzej KULIG
MSMirosław Szyłak-Szydłowski
Mirosław Szyłak-Szydłowski
Methodological aspects of odor studies in ex-post analyses for Polish wastewater management facilities were analyzed based on the example of a modernized and enlarged wastewater treatment plant (WWTP) in Mazovia, in the vicinity of the Warsaw agglomeration. It is a mechanical–biological treatment plant with increased efficiency of biogen removal, using activated sludge in the treatment process, with a maximum hydraulic capacity of 60,000 m3/day. Olfactometric research was carried out by means of a method based on identification and characterization of the odor plume emitted from the examined source. This paper presents the results of odor intensity assessment (in sensory examinations according to a 6-stage scale) and odor concentration measurement (using portable field olfactometers) after the completion of the project, and compares them with similar studies conducted before the commencement of the investment. A total of 10 measurement series were carried out before modernization, and 12 after modernization of the WWTP. Odor concentration and intensity were determined, and the current meteorological situation was assessed at the measurement and observation points (receptors) located within the premises (in total 462 points) and around the WWTP (342 points). In each series of measurements on the windward side of the treatment plant, the background of air pollution with odorous substances was marked. The research showed that air flowing into the area of the sewage treatment plant is clean in terms of odor. During the research, basic sources of odor nuisance were identified, and their impact before and after modernization was characterized. The results presented in radar diagrams show changes in the percentage distribution of frequency of occurrence of individual intensity values at receptor points within and outside the area of the treatment plant. After modernization, a significant decrease in the concentration of odor emitted from the sludge dewatering building and sludge containers was determined. The air-tightness of the sewage channel (covered with concrete slabs and sealed) resulted in a significant decrease in the concentration of odor emitted from this source. Waste (in particular, sewage sludge) collected in the emergency waste storage yard was identified as the main source of odor nuisance. The waste, even after modernization, was an emitter of odorous compounds spreading outside the area of the WWTP. Nevertheless, as a result of the investment, the desired effect of reduction of the degree of odor nuisance was achieved.

31 July 2017 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
MSMirosław Szyłak-Szydłowski
Mirosław Szyłak-Szydłowski
The basic principle of odor sampling from surface sources is based primarily on the amount of air obtained from a specific area of the ground, which acts as a source of malodorous compounds. Wind tunnels and flux chambers are often the only available, direct method of evaluating the odor fluxes from small area sources. There are currently no widely accepted chamber-based methods; thus, there is still a need for standardization of these methods to ensure accuracy and comparability. Previous research has established that there is a significant difference between the odor concentration values obtained using the Lindvall chamber and those obtained by a dynamic flow chamber. Thus, the present study compares sampling methods using a streaming chamber modeled on the Lindvall cover (using different wind speeds), a static chamber, and a direct sampling method without any screens. The volumes of chambers in the current work were similar, ~0.08 m3. This study was conducted at the mechanical-biological treatment plant in Poland. Samples were taken from a pile covered by the membrane. Measured odor concentration values were between 2 and 150 ouE/m3. Results of the study demonstrated that both chambers can be used interchangeably in the following conditions: odor concentration is below 60 ouE/m3, wind speed inside the Lindvall chamber is below 0.2 m/sec, and a flow value is below 0.011 m3/sec. Increasing the wind speed above the aforementioned value results in significant differences in the results obtained between those methods. In all experiments, the results of the concentration of odor in the samples using the static chamber were consistently higher than those from the samples measured in the Lindvall chamber. Lastly, the results of experiments were employed to determine a model function of the relationship between wind speed and odor concentration values. Implications: Several researchers wrote that there are no widely accepted chamber-based methods. Also, there is still a need for standardization to ensure full comparability of these methods. The present study compared the existing methods to improve the standardization of area source sampling. The practical usefulness of the results was proving that both examined chambers can be used interchangeably. Statistically similar results were achieved while odor concentration was below 60 ouE/m3 and wind speed inside the Lindvall chamber was below 0.2 m/sec. Increasing wind speed over these values results in differences between these methods. A model function of relationship between wind speed and odor concentration value was determined.

29 January 2021 in Processes
Verified
Journal Article
Open access
PDF file
Marta WiśniewskaMarta Wiśniewska
Marta Wiśniewska
MSMirosław Szyłak-Szydłowski
Mirosław Szyłak-Szydłowski
The mechanical-biological waste treatment plants (MBTP), which include the municipal waste biogas plants, have an important role in sustainable urban development. Some plants are equipped with a sewage pre-treatment plant, which is then directed to the sewerage system and the treatment plant. Others, on the other hand, have only a non-drainage tank. The parameters of technological sewage (TS) or processing technology could reduce sewage contamination rates. In addition to the quality of sewage from waste treatment plants, the emission of odours is also an important problem, as evidenced by the results obtained over the sewage pumping station tank. The conducted statistical analysis shows a significant positive correlation between odour concentration (cod) and volatile organic compounds (VOCs). Analysing the individual compounds, a high positive correlation was also found—the strongest being between H2S, NH3 and VOCs. In the case of sewage compounds, the insignificant correlation between P total and other parameters was found. For the rest of the compounds, the highest positive correlation was found between COD and BOD and N-NO2 and N-NH3 as well as COD and N-NO2. The dilution of sewage is only an ad hoc solution to the problem. Further work should be aimed at reducing sewage pollution rates. The obtained results indicate large pollution of technological sewage and a high level of odour and odorants concentration. The novelty and scientific contribution presented in the paper are related to analyses of various factors on technological sewage parameters and odour and odorant emission from TS tank at biogas plant processing municipal waste, which may be an important source of knowledge on the management of TS, its disposal and minimisation of emitted compound emissions.