Sergio Toscani

Prof. Dr. Sergio Toscani

Politecnico di Milano, DEIB
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2013 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LCLoredana Cristaldi
Loredana Cristaldi
Marco FaiferMarco Faifer
Marco Faifer
MRMarco Rossi
Marco Rossi
Sergio ToscaniSergio Toscani
Sergio Toscani
It is well known that in a photovoltaic (PV) plant, the modules are connected to switch-mode power converters to enhance the power output in every environmental condition. This task is performed by the maximum power point tracker (MPPT), which provides a current or voltage reference to the converter. Traditional perturb and observe or incremental conductance algorithms are not efficient in rapidly changing conditions, whereas a model-based (MB) MPPT offers a better dynamic performance. Because it is relatively easy to obtain an accurate model of a single PV panel, thus predicting the maximum power point voltage for given environmental conditions, MB MPPTs seemed to be attractive for employing in module integrated converters. Conventional MB MPPT algorithms, however, usually require an expensive pyranometer to properly operate. In this paper, starting from a new set of equations modeling a PV module, a novel MB MPPT technique, which does not require the direct measurement of the solar radiation, is proposed and experimentally validated.


15 April 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Marco FaiferMarco Faifer
Marco Faifer
Christian LauranoChristian Laurano
Christian Laurano
Roberto OttoboniRoberto Ottoboni
Roberto Ottoboni
Sergio ToscaniSergio Toscani
Sergio Toscani
Michele ZanoniMichele Zanoni
Michele Zanoni
Monitoring voltage harmonics represents one of the most important tasks in power quality assessment. In particular, the employed instrument transformer plays a key role in the achieved accuracy. Its harmonic measurement performance is typically evaluated by measuring its frequency response function. However, nonlinearities may have a nonnegligible impact on measurement uncertainty; for example, this occurs as far as the inductive voltage transformers are considered. This paper proposes a simple technique allowing the compensation of the most significant nonlinear effect that is the harmonic distortion produced by the large fundamental primary voltage. The method is first derived and introduced by means of numerical simulations and then implemented through a proper experimental setup. Results highlight remarkable accuracy improvements when realistic voltage waveforms are measured.

22 November 2010 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AFAlessandro Ferrero
Alessandro Ferrero
Simona SaliconeSimona Salicone
Simona Salicone
Sergio ToscaniSergio Toscani
Sergio Toscani
The evaluation of the spectral components of a signal by means of discrete Fourier transform or fast Fourier transform algorithms is subject to leakage errors whenever the sampling frequency is not coherent with the signal frequency. Smoothing windows are used to mitigate these errors, and interpolation methods are applied in the frequency domain to reduce them further on. However, if cosine windows are employed, closed-form formulas for the evaluation of harmonic frequencies can be used only with the Rife-Vincent class I windows, while approximated formulas have to be used in other cases. In both cases, a high computation burden is required. This paper proposes a fast interpolation method, independent of the window type and order, based on suitable lookup tables. Experimental results are reported, and the accuracy is discussed, proving that the method provides results as good as those obtained with other methods, without requiring the same high computation burden.

29 March 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Marco FaiferMarco Faifer
Marco Faifer
Christian LauranoChristian Laurano
Christian Laurano
Roberto OttoboniRoberto Ottoboni
Roberto Ottoboni
Sergio ToscaniSergio Toscani
Sergio Toscani
Michele ZanoniMichele Zanoni
Michele Zanoni
Voltage instrument transformers are usually tested at the rated frequency. In order to assess their performance in measuring harmonic components, typically, the frequency response function (FRF) is evaluated. Therefore, this conventional characterization does not consider nonlinear effects that may have a nonnegligible impact on the accuracy, especially when the transducer under test is represented by an inductive voltage transformer (VT). In this paper, a simple procedure for the characterization of voltage instrument transformers is presented. The method is based on the concept of best linear approximation of a nonlinear system. It requires applying a class of excitation signals that resembles the typical voltage waveforms found in power systems. Results consist of the FRF that permits the best linear compensation of the transducer response, and sample variances that allow quantifying the impact of noise and nonlinearities on the accuracy. The method is presented and explained by means of numerical simulations. After that, it has been applied to the characterization of a conventional inductive VT. Experimental results show how the accuracy of the transducer under test is heavily degraded by nonlinear phenomena when low-order voltage harmonics are considered.

7 May 2014 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Giovanni DotelliGiovanni Dotelli
Giovanni Dotelli
RFRoberto Ferrero
Roberto Ferrero
Paola Gallo StampinoPaola Gallo Stampino
Paola Gallo Stampino
Saverio LatorrataSaverio Latorrata
Saverio Latorrata
Sergio ToscaniSergio Toscani
Sergio Toscani
This paper discusses the possibility to use the current ripple introduced by switch mode power converters for low-cost monitoring of polymer electrolyte membrane (PEM) fuel cell (FC) state-of-health, suitable for commercial applications that cannot afford dedicated instrumentation. In more details, an estimate of the ohmic resistance, which is a good indicator of the membrane water content, can be obtained from the high-frequency ripple response by data processing in the frequency domain, while lower frequency ripple at 100/120 Hz (when present) is in the typical frequency range of activation processes. All the available impedance estimates, together with the dc voltage measurement, can be used to promptly detect FC drying and flooding, that are the two opposite failure modes as far as water balance is concerned. The proposed diagnostic approach is tested on a single PEM FC in drying and flooding conditions, by emulating three-phase and single-phase inverter ripples by means of an electronic load.