This paper presents the improvements of the hosting capacity of photovoltaics (PVs) and electric vehicles (EVs) in a stand-alone microgrid (MG) with an energy storage system (ESS) by consider-ing a model predictive control (MPC) based energy management system. The system is configured as an MG, including PVs, an ESS, a diesel generator (DG), and several loads with EVs. The DG is controlled to operate at rated power and the MPC algorithm is used in a stand-alone MG, which supplies the energy demanded for several loads with EVs. The hosting capacity of the load in-cluding the EV and PVs can be expanded through the ESS to the terminal node of the microgrid. In this case, the PVs and the load can be connected in excess of the capacity of the diesel genera-tor, and each bus in the feeder complies with the voltage range required by the grid. The effec-tiveness of the proposed algorithm to resolve the hosting capacity is demonstrated by numerical simulations.
The characteristics of oscillation modes, such as interarea, regional, and subsynchronous modes, can vary during a power system fault, which can cause switching and control actions in the power system. Transient data of the modal response due to such a fault can be acquired through phasor measurement units (PMUs). When the transient data have a long duration, it is desirable to perform modal identification separately on each segment of the transient data, so as to reflect the varying characteristics of oscillation modes. A conventional discrete Fourier transform (DFT)-based method for parametric modal identification cannot be efficiently applied to such a segment dataset. In this paper, a DFT-based method with an exponential window function is proposed to identify oscillation modes from each segment of transient data in PMUs. This window function allows the application of the least squares method (LSM) for modal identification in the same manner as the conventional method. The accuracy of identification of the proposed method is compared with those of the conventional method and a Prony method through synthetic data of transient responses. Its feasibility is also verified by identifying real-world oscillation modes from transient data in PMUs.
With the intention of keep the customer voltage within a nominal voltage boundary (the South Korea voltage regulation in range of 220 V ± 6% for a single phase), the SVR (step voltage regulator) method in the primary feeder has been seriously systematized for the scheduled tap time delay (from a minimum of 120 s to a maximum of 900 s). The voltage must be compensated for the primary feeder during the tap delay time of SVR. However, when RES (renewable energy resource) is connected with the primary feeder, the customer voltage could exceed the nominal voltage boundary. Therefore, in order to keep the secondary feeder voltage within the nominal voltage boundary at all the time, this paper proposed a novel voltage control method in the primary feeder using coordinated controls between ESS (energy storage system) and SVR. Through the simulations based on PSCAD/EMTDC which is analysis tool of power system, it is confirmed that the proposed algorithm can effectively control the customer voltage within allowable limitation.
30 April 2012 in Journal of the Korean Solar Energy Society