Piotr Pyrka

Piotr Pyrka


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Energy
Verified
Journal Article
Closed access
MCMaciej Chorowski
Maciej Chorowski
PPPiotr Pyrka
Piotr Pyrka

17 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
MCMaciej Chorowski
Maciej Chorowski
PPPiotr Pyrka
Piotr Pyrka
ZRZbigniew Rogala
Zbigniew Rogala
PCPiotr Czupryński
Piotr Czupryński
The main challenge facing adsorption cooling technology is low Coefficient of Performance (COP), which becomes a key factor of the commercialization of this technology. This paper presents the results of modifications, aiming to increase COP, applied to the control software of a prototype three-bed two-evaporator adsorption chiller. Changes were mainly related to the sequence of the switching valves and had no influence on the hardware of the chiller. The sequence changes enabled the introduction of heat recovery and mass regeneration. Moreover, the precooling process was improved. The applied modifications not only resulted in significant improvement of the chiller’s COP, but also improved the cooperation adsorption unit heating source, which is of great importance in case of district heating supply. The improvement was also observed concerning such operational aspects as noise and vibrations. In the authors’ opinion, the presented modifications can be introduced to most exploited adsorption chillers and could potentially lead to similar improvements in performance.

29 April 2023 in Processes
Verified
Journal Article
Open access
PDF file
SASameh Alsaqoor
Sameh Alsaqoor
PPPiotr Pyrka
Piotr Pyrka
Ali AlahmerAli Alahmer
Ali Alahmer
SASamer As'ad
Samer As'ad
NBNabil Beithu
Nabil Beithu
PKPatryk Kotomski
Patryk Kotomski
This study investigates the impact of changes in velocity profiles on the measurement inaccuracies of gas flow streams detected by an ultrasonic flowmeter. The cross-sectional velocity profile was influenced by the downhill flow rate, causing variations in the shape factor coefficient. The flowmeter processing equation should consider the factor of shape coefficient variations. Consideration for these variations can result in errors in the measurement of the flow stream. The processing equation assumes a single, constant value for the shape factor coefficient, which can lead to inaccuracies. This article covers the inaccuracies of the transit-time ultrasonic flowmeter caused by a change in the velocity profile of the flowing gas, such as air. A realistic flow system was established with measured flow rates ranging from 43 m3/h to 225 m3/h. The findings of this study can serve as a valuable reference for the design and implementation of more accurate and efficient flow measurement systems that can enhance process efficiency.