Samer As'ad

Dr. Samer As'ad

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
RGRania Ghoniem
Rania Ghoniem
Ali AlahmerAli Alahmer
Ali Alahmer
Hegazy RezkHegazy Rezk
Hegazy Rezk
SASamer As'ad
Samer As'ad
Renewable energy solutions play a crucial role in addressing the growing energy demands while mitigating environmental concerns. This study examines the techno-economic viability and sensitivity of utilizing solar photovoltaic/polymer electrolyte membrane (PEM) fuel cells (FCs) to meet specific power demands in NEOM, Saudi Arabia. The novelty of this study lies in its innovative approach to analyzing and optimizing PV/PEMFC systems, aiming to highlight their economic feasibility and promote sustainable development in the region. The analysis focuses on determining the optimal size of the PV/PEMFC system based on two critical criteria: minimum cost of energy (COE) and minimum net present cost (NPC). The study considers PEMFCs with power ratings of 30 kW, 40 kW, and 50 kW, along with four PV panel options: Jinko Solar, Powerwave, Tindo Karra, and Trina Solar. The outcomes show that the 30 kW PEMFC and the 201 kW Trina Solar TSM-430NEG9R.28 are the most favorable choices for the case study. Under these optimal conditions, the study reveals the lowest values for NPC at USD 703,194 and COE at USD 0.498 per kilowatt-hour. The levelized cost of hydrogen falls within the range of USD 15.9 to 23.4 per kilogram. Furthermore, replacing the 30 kW Trina solar panel with a 50 kW Tindo PV module results in a cost reduction of 32%. The findings emphasize the criticality of choosing optimal system configurations to attain favorable economic outcomes, thereby facilitating the adoption and utilization of renewable energy sources in the region. In conclusion, this study stands out for its pioneering and thorough analysis and optimization of PV/PEMFC systems, providing valuable insights for sustainable energy planning in NEOM, Saudi Arabia.

28 September 2023 in Membranes
Verified
Journal Article
Open access
PDF file
RGRania Ghoniem
Rania Ghoniem
TWTabbi Wilberforce
Tabbi Wilberforce
Hegazy RezkHegazy Rezk
Hegazy Rezk
SASamer As'ad
Samer As'ad
Ali AlahmerAli Alahmer
Ali Alahmer
The adoption of Proton Exchange Membrane (PEM) fuel cells (FCs) is of great significance in diverse industries, as they provide high efficiency and environmental advantages, enabling the transition to sustainable and clean energy solutions. This study aims to enhance the output power of PEM-FCs by employing the Adaptive Neuro-Fuzzy Inference System (ANFIS) and modern optimization algorithms. Initially, an ANFIS model is developed based on empirical data to simulate the output power density of the PEM-FC, considering factors such as pressure, relative humidity, and membrane compression. The Salp swarm algorithm (SSA) is subsequently utilized to determine the optimal values of the input control parameters. The three input control parameters of the PEM-FC are treated as decision variables during the optimization process, with the objective to maximize the output power density. During the modeling phase, the training and testing data exhibit root mean square error (RMSE) values of 0.0003 and 24.5, respectively. The coefficient of determination values for training and testing are 1.0 and 0.9598, respectively, indicating the successfulness of the modeling process. The reliability of SSA is further validated by comparing its outcomes with those obtained from particle swarm optimization (PSO), evolutionary optimization (EO), and grey wolf optimizer (GWO). Among these methods, SSA achieves the highest average power density of 716.63 mW/cm2, followed by GWO at 709.95 mW/cm2. The lowest average power density of 695.27 mW/cm2 is obtained using PSO.

1 March 2024 in Nature Environment and Pollution Technology
Verified
Journal Article
Closed access
SASamer As'ad
Samer As'ad
Energy security and stable supply are the most important aspects for any nation. The rising need for energy, caused by both population growth and economic activity, is a problem for many nations throughout the world. Consequently, they have to find a way to meet energy demand while also making sure it is inexpensive and sustainable. The use of renewable energy has gradually become one that is being given a lot of attention since it does not cause any harm to the environment. On the other hand, renewable energy is gaining popularity for a variety of different reasons. A paradigm shift toward renewable resources is relevant, as they have the ability to lessen reliance on fossil fuels and decrease environmental consequences; this article will provide several reasons why renewable energy is attracting attention on a global scale. Indeed, renewable energy is plentiful, clean, and might one day provide all of our energy needs. A country's carbon footprint and reliance on fossil fuels may be reduced by investing in renewable energy sources. In addition, there are several health and environmental problems associated with air and water pollution; nevertheless, renewable energy may assist decrease these problems.

5 September 2023 in Processes
Verified
Journal Article
Open access
PDF file
Hegazy RezkHegazy Rezk
Hegazy Rezk
Ali AlahmerAli Alahmer
Ali Alahmer
RGRania Ghoniem
Rania Ghoniem
SASamer As'ad
Samer As'ad
Waste concrete powder (WCP) is emerging as a potential method of adoption for CO2 sequestration due to its ability to chemically react with carbon dioxide and trap it within its structure. This study explores the application of artificial intelligence (AI) and the Marine Predators Algorithm (MPA) to maximize the absorption of CO2 from waste concrete powder generated by recycling plants for building and demolition debris. Initially, a model is developed to assess CO2 uptake according to carbonation time (CT) and water-to-solid ratio (WSR), utilizing the adaptive neuro-fuzzy inference system (ANFIS) modeling approach. Subsequently, the MPA is employed to estimate the optimal values for CT and WSR, thereby maximizing CO2 uptake. A significant improvement in modeling accuracy is evident when the ANOVA method is replaced with ANFIS, leading to a substantial increase of approximately 19% in the coefficient of determination (R-squared) from 0.84, obtained through ANOVA, to an impressive 0.9999 obtained through the implementation of ANFIS; furthermore, the utilization of ANFIS yields a substantial reduction in the root mean square error (RMSE) from 1.96, as indicated by ANOVA, to an impressively low value of 0.0102 with ANFIS. The integration of ANFIS and MPA demonstrates impressive results, with a nearly 30% increase in the percentage value of CO2 uptake. The highest CO2 uptake of 3.86% was achieved when the carbonation time was 54.3 h, and the water-to-solid ratio was 0.27. This study highlights the potential of AI and the MPA as effective tools for optimizing CO2 absorption from waste concrete powder, contributing to sustainable waste management practices in the construction industry.

29 April 2023 in Processes
Verified
Journal Article
Open access
PDF file
SASameh Alsaqoor
Sameh Alsaqoor
PPPiotr Pyrka
Piotr Pyrka
Ali AlahmerAli Alahmer
Ali Alahmer
SASamer As'ad
Samer As'ad
NBNabil Beithu
Nabil Beithu
PKPatryk Kotomski
Patryk Kotomski
This study investigates the impact of changes in velocity profiles on the measurement inaccuracies of gas flow streams detected by an ultrasonic flowmeter. The cross-sectional velocity profile was influenced by the downhill flow rate, causing variations in the shape factor coefficient. The flowmeter processing equation should consider the factor of shape coefficient variations. Consideration for these variations can result in errors in the measurement of the flow stream. The processing equation assumes a single, constant value for the shape factor coefficient, which can lead to inaccuracies. This article covers the inaccuracies of the transit-time ultrasonic flowmeter caused by a change in the velocity profile of the flowing gas, such as air. A realistic flow system was established with measured flow rates ranging from 43 m3/h to 225 m3/h. The findings of this study can serve as a valuable reference for the design and implementation of more accurate and efficient flow measurement systems that can enhance process efficiency.

1 January 2024 in Ecological Engineering & Environmental Technology
Verified
Journal Article
Open access
SASamer As'ad
Samer As'ad
Concentrated Solar Power (CSP) is a promising form of renewable energy that harnesses the immense power of the sun to generate electricity. It employs various mechanisms to concentrate sunlight onto a receiver, thereby producing high-temperature heat. This heat can be stored and converted into...