Xiaolin Chu

Dr. Xiaolin Chu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
XCXiaolin Chu
Xiaolin Chu
DYDong Yang
Dong Yang
JLJia Li
Jia Li
The combined cooling, heating, and power (CCHP) system, which is a sustainable distributed energy system, has attracted increasing attention due to the associated economic, environmental, and energy benefits. Currently, the enforcement of carbon emission regulations has become an increasingly concerning issue globally. In this paper, a multi-objective optimization model is established to evaluate the CCHP system under two different carbon emission regulation policies in terms of economic benefit, environmental sustainability, and energy advantage. A nonlinear programming optimization model is formulated and solved by using the particle swarm optimization (PSO) algorithm. The results from the case studies demonstrate that when considering carbon tax regulation, the cost savings of the optimal CCHP system strategy were on average 10.0%, 9.1%, 17.0%, 22.1%, and 20.9% for the office, supermarket, hotel, school, and hospital in China, respectively, compared with the conventional energy supply system. On the other hand, when considering carbon trading regulation, the optimal CCHP system strategy can lead to a 10.0%, 8.9%, 16.8%, 21.6%, and 20.5% cost-saving for the five different building categories, respectively. Furthermore, the optimal CCHP system strategy for the five buildings, i.e., an average of 39.6% carbon dioxide emission (CDE) reduction and 26.5% primary energy consumption (PEC) saving, can be achieved under carbon emission regulations.

13 June 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
XCXiaolin Chu
Xiaolin Chu
YGYuntian Ge
Yuntian Ge
XZXue Zhou
Xue Zhou
Lin LiLin Li
Lin Li
DYDong Yang
Dong Yang
Electric vehicles (EVs) have obtained increasing public interest due to the associated economic and environmental benefits. Recently, studies regarding the economic advantages of adopting EVs as energy storages for commercial/residential buildings are emerging. In fact, according to the U.S. Energy Information Administration, the industrial sector consumes more energy than all of the other sectors combined, which is about 54% of the world’s total delivered energy. The energy consumption pattern in manufacturing facilities is based on production schedules and the heat transfer between machines and the ambient surroundings, thus, differs greatly from commercial/residential buildings. However, little research attention has been given to analyse the synergies of integrating EVs and manufacturing facilities to improve energy efficiency. To fill this research gap, in this study, a comprehensive model is established to evaluate the economic and environmental performance of an energy sharing system that consists of the EVs, power grid, and manufacturing facilities (EPM) under Time-of-Use (TOU) electricity tariff. The model is formulated as a mixed integer nonlinear programming format by considering practical production schedules, heat exchange between machines and ambient surroundings, as well as the heating, ventilation, and air conditioning (HVAC) system. The case study results indicate that the presented EPM energy sharing system has great potential to reduce energy cost and CO2 emissions. In addition, compared to the results from winter scenarios, it is shown that more cost savings can be achieved in summer days.

27 December 2022 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
XCXiaolin Chu
Xiaolin Chu
PWPeng Wang
Peng Wang
DYDong Yang
Dong Yang
Microgrids allow energy exchange among multiple interconnected microgrids for greater energy efficiency and collective economic interest. However, in some cases, the benefit of some microgrids within the network may not be uncertain. In view of the increasing development of electric vehicles (EVs), a multiobjective model is proposed to improve the performance of microgrids by integrating electric vehicles-to-grid (V2G) and vehicles-to-building (V2B) based on global and individual benefit balance. Two reference models are built to verify the validity of the proposed method, and models are formulated as mixed integer linear programming formats solved by the weighting method. A set of parameters of microgrids are adopted to model the driver behaviors (e.g., available hours of EV), energy transactions (e.g., electricity), performance factor (e.g., emission factor), distributed energy (e.g., solar panel), and energy load of five commercial buildings (e.g., hotel) located in Shanghai. Simulation results demonstrate the effectiveness of the operation decision models in the energy management of microgrids under neutral, proeconomic, proenvironmental, and proenergy weighting scenarios. The case study results specify that the proposed method can achieve operational cost, CO2 emission, and primary energy consumption reductions for each microgrid, with total benefits declining slightly.

25 February 2026 in Energies
Verified
Journal Article
Open access
PDF file
XCXiaolin Chu
Xiaolin Chu
LYLinsen li Yin
Linsen li Yin
The exponential growth in demand for data storage and computing has led to a rapid expansion in the energy consumption and carbon emissions of data centers (DCs). Hybrid energy systems that integrate renewable energy sources are regarded as a sustainable and low-carbon solution for powering the DCs. This study proposes an optimal cooperation scheduling strategy for the hybrid energy system powering the DC and electric vehicles (EVs). The strategy is based on load transferring and operates within a carbon trading mechanism, explicitly addressing the coupling between computational loads and power consumption. An optimization model is constructed that considers economic objectives, including operational cost and a stepped carbon trading cost, to obtain optimal energy dispatch and computational task allocation strategies. This framework ensures the economic interests of EVs’ owners while satisfying the energy demands of both the DC and the EVs. The results of a case study based in Shanghai demonstrate that the proposed hybrid energy system with multiple sources has significant economic and environmental advantages in spite of operational complexity. Furthermore, the collaborative strategy further enhances the cost reduction and carbon emission reduction. Specifically, the cooperative strategy achieves a 5.21% reduction in total cost compared to Case 1 (without V2G) and a 22.80% reduction compared to Case 2 (without computing task transferring). By adopting the optimal scheduling solution, carbon emissions can be reduced by 16.74% relative to Case 1 while remaining at a level comparable to Case 2. Furthermore, the impact of the carbon trading mechanism on the system’s cost and carbon emissions is analyzed. The results indicate that while a stricter carbon trading mechanism leads to an increase in the total cost, it also results in a reduction in carbon emission from the DC’s hybrid energy system.

18 July 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
XCXiaolin Chu
Xiaolin Chu
WPWang Peng
Wang Peng
RZRuijuan Zhao
Ruijuan Zhao
The rapid growth in data storage and computing demand has substantially increased the energy consumption and carbon emissions of the data center (DC). Energy storage systems facilitate multi-source energy coordination, while DCs are playing an expanding role in the demand response (DR) program. This paper proposes an optimal energy and workload dispatch model for a DC cluster (DCC) integrating distributed energy storage (DES) and shared energy storage (SES) under the carbon trading mechanism. A Mixed-Integer Nonlinear Programming (MINLP) model is formulated to minimize the economic objective, including the electricity-related cost and carbon trading cost. Case study results show that, compared with a DES-only configuration, the DCC incorporating both DES and SES can achieve a 46.19% reduction in cost and a 54.02% reduction in carbon emission. DR participation yields further reductions in both cost and carbon emission. The scalability of the proposed model is validated by evaluating its computational performance across DCC instances with varying numbers of constituent DCs. The study also examines the effects of carbon prices and energy storage capacities on DCC performance. A higher carbon price reduces carbon emissions but increases costs, whereas larger DES and SES capacities reduce both. The proposed model proves solvable and well-behaved across a wide range of renewable energy generation conditions and computing workloads. This research provides practical implications for the sustainable development of DCs under the carbon trading mechanism.

24 January 2025 in International Game Theory Review
Verified
Journal Article
Closed access
XKXiaodan Kong
Xiaodan Kong
RMRan Ma
Ran Ma
XCXiaolin Chu
Xiaolin Chu
XYXunan Ye
Xunan Ye