Muhammad Hafiz Abu Bakar

Dr. Muhammad Hafiz Abu Bakar


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
TYT. K Yadav
T. K Yadav
RNRadhakrishnan Narayanaswamy
Radhakrishnan Narayanaswamy
MBMuhammad Hafiz Abu Bakar
Muhammad Hafiz Abu Bakar
YKY. Mustapha Kamil
Y. Mustapha Kamil
MMMOHD ADZIR MAHDI
MOHD ADZIR MAHDI
We demonstrate refractive index sensors based on single mode tapered fiber and its application as a biosensor. We utilize this tapered fiber optic biosensor, operating at 1550 nm, for the detection of protein (gelatin) concentration in water. The sensor is based on the spectroscopy of mode coupling based on core modes-fiber cladding modes excited by the fundamental core mode of an optical fiber when it transitions into tapered regions from untapered regions. The changes are determined from the wavelength shift of the transmission spectrum. The proposed fiber sensor has sensitivity of refractive index around 1500 nm/RIU and for protein concentration detection, its highest sensitivity is 2.42141 nm/%W/V.

14 November 2012 in Sensors
Verified
Journal Article
Open access
PDF file
MHMuhammad Rosdi Abu Hassan
Muhammad Rosdi Abu Hassan
MBMuhammad Hafiz Abu Bakar
Muhammad Hafiz Abu Bakar
KDKATRINA D Dambul
KATRINA D Dambul
FAFaisal Rafiq Mahamd Adikan
Faisal Rafiq Mahamd Adikan
In this paper, we present the development and testing of an optical-based sensor for monitoring the corrosion of reinforcement rebar. The testing was carried out using an 80% etched-cladding Fibre Bragg grating sensor to monitor the production of corrosion waste in a localized region of the rebar. Progression of corrosion can be sensed by observing the reflected wavelength shift of the FBG sensor. With the presence of corrosion, the etched-FBG reflected spectrum was shifted by 1.0 nm. In addition, with an increase in fringe pattern and continuously, step-like drop in power of the Bragg reflected spectrum was also displayed.

1 March 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
YKY. Mustapha Kamil
Y. Mustapha Kamil
MBMuhammad Hafiz Abu Bakar
Muhammad Hafiz Abu Bakar
MMM.A. Mustapa
M.A. Mustapa
MYMohd Yaacob
Mohd Yaacob
NAN.H.Z. Abidin
N.H.Z. Abidin
HLH.J. Lee
H.J. Lee

13 October 2014 in IEEE Photonics Journal
Verified
Journal Article
Open access
MAM. I. Md Ali
M. I. Md Ali
SIS. A. Ibrahim
S. A. Ibrahim
MBMuhammad Hafiz Abu Bakar
Muhammad Hafiz Abu Bakar
ANAhmad Shukri Muhammad Noor
Ahmad Shukri Muhammad Noor
SAS.B.A. Anas
S.B.A. Anas
MMM. A. Mahdi
M. A. Mahdi
An all-fiber comb filter using a tapered-erbium-doped fiber in a Mach-Zehnder interferometer structure is presented. The free spectral range, extinction ratio, bandwidth, and interference pattern of the comb filter can be shaped by controlling the taper waist length and the length of up and down taper transition regions. By varying the taper waist length from 5 to 25 mm, the free spectral range changes from 14.7 to 1.0 nm, and the linewidth varies from 3.3 to 0.3 nm, respectively. We demonstrate a tunable dual-wavelength laser by using the tapered-erbium-doped fiber as a gain medium as well as a wavelength-selective element. The laser can be tuned at a resolution of 0.2 nm with a side-mode suppression ratio of up to 46.88 dB and a linewidth of 0.09 nm.

30 January 2015 in Optics Express
Verified
Journal Article
Closed access
PDF file
SIS. A. Ibrahim
S. A. Ibrahim
NRN. A. Rahman
N. A. Rahman
MBMuhammad Hafiz Abu Bakar
Muhammad Hafiz Abu Bakar
SGSaad Hayatu Girei
Saad Hayatu Girei
MYMohd Yaacob
Mohd Yaacob
MMMOHD ADZIR MAHDI
MOHD ADZIR MAHDI
We demonstrate an ammonia sensor composed of a tapered multimode fiber coated with polyaniline nanofibers that operates at room temperature (26°C). The optical properties of the polyaniline layer changes when it is exposed to ammonia, leading to a change in the absorption of evanescent field. The fiber sensor was tested by exposing it to ammonia at different concentrations and the absorbance is measured using a spectrophotometer system. Measured response and recovery times are about 2.27 minutes and 9.73 minutes, respectively. The sensor sensitivity can be controlled by adjusting the tapered fiber diameter and the highest sensitivity is achieved when the diameter is reduced to 20 µm.

1 May 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
HMHusam Abduldaem Mohammed
Husam Abduldaem Mohammed
SRSuraya Abdul Rashid
Suraya Abdul Rashid
MBMuhammad Hafiz Abu Bakar
Muhammad Hafiz Abu Bakar
SAS.B.A. Anas
S.B.A. Anas
MMMohd Adzir Mahdi
Mohd Adzir Mahdi
MYMohd Yaacob
Mohd Yaacob