Maria Goreti Ferreira Sales

Prof. Dr. Maria Goreti Ferreira Sales

BioMark sensor research/UC, Faculty of Sciences and Technology, Coimbra University, 3004-531 Coimbra, Portugal
+1
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
ACAna R. Cardoso
Ana R. Cardoso
Felismina T.C. MoreiraFelismina T.C. Moreira
Felismina T.C. Moreira
Rúben FernandesRúben Fernandes
Rúben Fernandes
Maria Goreti Ferreira SalesMaria Goreti Ferreira Sales
Maria Goreti Ferreira Sales
This work, describes for the first time, a simple biosensing design to yield an ultrasensitive electrochemical biosensor for a cancer biomarker detection, miRNA-155, with linear response down to the attomolar range. MiRNA-155 was selected for being overexpressed in breast cancer. The biosensor was assembled in two stages: (1) the immobilization of the anti-miRNA-155 that was thiol modified on an Au-screen printed electrode (Au-SPE), followed by (2) blocking the areas of non-specific binding with mercaptosuccinic acid. Atomic force microscopy (AFM) and electrochemical techniques including cyclic voltammetry (CV), impedance spectroscopy (EIS) and square wave voltammetry (SWV) confirmed the surface modification of these devices and their ability to hybridize successfully and stably with miRNA-155. The final biosensor provided a sensitive detection of miRNA-155 from 10 aM to 1.0 nM with a low detection limit (LOD) of 5.7 aM in real human serum samples. Good results were obtained in terms of selectivity towards breast cancer antigen CA-15.3 and bovine serum albumin (BSA). Raw fluid extracts from cell-lines of melanoma did not affect the biosensor response (no significant change of the blank), while raw extracts from breast cancer yielded a positive signal against miRNA-155. This simple and sensitive strategy is a promising alternative for simultaneous quantitative analysis of multiple miRNA in physiological fluids for biomedical research and point-of-care (POC) diagnosis.

1 January 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
ACAna R. Cardoso
Ana R. Cardoso
Ana MarquesAna Marques
Ana Marques
LSLídia Santos
Lídia Santos
ACAlexandre F. Carvalho
Alexandre F. Carvalho
FCFlorinda M. Costa
Florinda M. Costa
Elvira FortunatoElvira Fortunato
Elvira Fortunato

24 October 2021 in Advanced Materials Interfaces
Verified
Journal Article
Closed access
PDF file
Tomás PinheiroTomás Pinheiro
Tomás Pinheiro
SSSara Silvestre
Sara Silvestre
JCJoão Coelho
João Coelho
Ana MarquesAna Marques
Ana Marques
Rodrigo MartinsRodrigo Martins
Rodrigo Martins
Elvira FortunatoElvira Fortunato
Elvira Fortunato

1 June 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
JRJosé Adolfo Ribeiro
José Adolfo Ribeiro
Carlos PereiraCarlos Pereira
Carlos Pereira
ASA. Fernando Silva
A. Fernando Silva
Maria Goreti Ferreira SalesMaria Goreti Ferreira Sales
Maria Goreti Ferreira Sales
In this work, electrically-conducting poly(Toludine Blue) was employed for the first time as synthetic receptor film, prepared by Molecular Imprinting strategies and using electrochemical methods, for the specific screening of breast cancer biomarker Carbohydrate Antigen 15-3 (CA 15-3). The protein imprinted poly(Toluidine Blue) film was grown in a pre-formed Toluidine Blue (TB) tailed SAM at the AuSPE surface, which greatly enhanced the stability against degradation of the Molecular Imprinted Polymer (MIP) film at the electrode surface. The MIP receptor film recognition ability towards the protein was investigated by fitting data to Freundlich isotherm. The binding affinity (KF) obtained for the MIP system was significantly higher (~ 12-fold) to that obtained for the NIP system, demonstrating the success of the approach in creating imprinted materials that specifically respond to CA 15-3 protein. The incubation of the MIP modified electrode with increasing concentration of protein (from 0.10 U mL-1 to 1000 U mL-1) resulted in a decrease of the ferro/ferricyanide redox current. The device displayed linear response from 0.10 U mL-1 to 100 U mL-1 and LODs below 0.10 U mL-1 were obtained from calibration curves built in neutral buffer and diluted artificial serum, using DPV technique, enabling the detection of the protein biomarker at clinically relevant levels. The developed MIP biosensor was applied to the determination of CA 15-3 in spiked serum samples with satisfactory results. The developed device provides a new strategy for sensitive, rapid, simple and cost-effective screening of CA 15-3 biomarker. Importantly, the overall approach seems suitable for point-of-care (PoC) use in clinical context.

1 March 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
BSBárbara V.M. Silva
Bárbara V.M. Silva
BRBlanca A.G. Rodríguez
Blanca A.G. Rodríguez
Maria Goreti Ferreira SalesMaria Goreti Ferreira Sales
Maria Goreti Ferreira Sales
María del Pilar T. SotomayorMaría del Pilar T. Sotomayor
María del Pilar T. Sotomayor
RDRosa Fireman Dutra
Rosa Fireman Dutra

1 November 2019 in Analytica Chimica Acta
Verified
Journal Article
Closed access
TRTânia S.C.R. Rebelo
Tânia S.C.R. Rebelo
Renata CostaRenata Costa
Renata Costa
Ana Teresa Silva Cardoso BrandãoAna Teresa Silva Cardoso Brandão
Ana Teresa Silva Cardoso Brandão
ASA. Fernando Silva
A. Fernando Silva
Maria Goreti Ferreira SalesMaria Goreti Ferreira Sales
Maria Goreti Ferreira Sales
Carlos PereiraCarlos Pereira
Carlos Pereira