Memristive synapses, the most promising passive devices for synaptic interconnections in artificial neural networks, are the driving force behind recent research on hardware neural networks. Despite significant efforts to utilize memristive synapses, progress to date has only shown the possibility of building a neural network system that can classify simple image patterns. In this article, we report a high-density cross-point memristive synapse array with improved synaptic characteristics. The proposed PCMO-based memristive synapse exhibits the necessary gradual and symmetrical conductance changes and has been successfully adapted to a neural network system. The system learns and later recognizes, the human thought pattern corresponding to three vowels, i.e. /a /, /i / and /u/, using electroencephalography signals generated while a subject imagines speaking vowels. Our successful demonstration of a neural network system for EEG pattern recognition is likely to intrigue many researchers and stimulate a new research direction.
Realization of memristor‐based neuromorphic hardware system is important to achieve energy efficient bigdata processing and artificial intelligence in integrated device system‐level. In this sense, uniform and reliable titanium oxide (TiOx) memristor array devices are fabricated to be utilized as constituent device element in hardware neural network, representing passive matrix array structure enabling vector‐matrix multiplication process between multisignal and trained synaptic weight. In particular, in situ convolutional neural network hardware system is designed and implemented using a multiple 25 × 25 TiOxmemristor arrays and the memristor device parameters are developed to bring global constant voltage programming scheme for entire cells in crossbar array without any voltage tuning peripheral circuit such as transistor. Moreover, the learning rate modulation during in situ hardware training process is successfully achieved due to superior TiOxmemristor performance such as threshold uniformity (≈2.7%), device yield (> 99%), repetitive stability (≈3000 spikes), low asymmetry value of ≈1.43, ambient stability (6 months), and nonlinear pulse response. The learning rate modulable fast‐converging in situ training based on direct memristor operation shows five times less training iterations and reduces training energy compared to the conventional hardware in situ training at ≈95.2% of classification accuracy.
Cardiac disease is one of the main causes of catastrophic mortality. Therefore, detecting the symptoms of cardiac disease as early as possible is important for increasing the patient’s survival. In this study, a compact and effective architecture for detecting atrial fibrillation (AFib) and myocardial ischemia is proposed. We developed a portable device using this architecture, which allows real-time electrocardiogram (ECG) signal acquisition and analysis for cardiac diseases. A noisy ECG signal was preprocessed by an analog front-end consisting of analog filters and amplifiers before it was converted into digital data. The analog front-end was minimized to reduce the size of the device and power consumption by implementing some of its functions with digital filters realized in software. With the ECG data, we detected QRS complexes based on wavelet analysis and feature extraction for morphological shape and regularity using an ARM processor. A classifier for cardiac disease was constructed based on features extracted from a training dataset using support vector machines. The classifier then categorized the ECG data into normal beats, AFib, and myocardial ischemia. A portable ECG device was implemented, and successfully acquired and processed ECG signals. The performance of this device was also verified by comparing the processed ECG data with high-quality ECG data from a public cardiac database. Because of reduced computational complexity, the ARM processor was able to process up to a thousand samples per second, and this allowed real-time acquisition and diagnosis of heart disease. Experimental results for detection of heart disease showed that the device classified AFib and ischemia with a sensitivity of 95.1% and a specificity of 95.9%. Current home care and telemedicine systems have a separate device and diagnostic service system, which results in additional time and cost. Our proposed portable ECG device provides captured ECG data and suspected waveform to identify sporadic and chronic events of heart diseases. This device has been built and evaluated for high quality of signals, low computational complexity, and accurate detection.
15 May 2019 in IEEE Transactions on Electron Devices
In this study, a circuit technique and training algorithm that minimizes the effect of stuck-at-faults (SAFs) within a memristor crossbar array of neural networks (NNs) are presented. To improve the network performance in the presence of SAFs, a conventional transimpedance amplifier, which is used for summing the currents that flow through the memristors, is modified to ensure that the amplifier output is within the appropriate operating range. Further improvement in the network performance is achieved by using the proposed training algorithm, which utilizes the locations and values of faulty memristors for network training. A feedforward NN employing 32 x 32 memristor crossbar arrays is implemented to verify the performance improvement in the NNs using the proposed circuit technique and training algorithm.
We demonstrate a multispectral double-image-based cryptosystem that exploits only a tiny number of random white noise samples for proper decryption. Primarily, one of the two downsampled images is converted into the phase function after being shuffled by Arnold transform (AT), while the other image is modulated as an amplitude-based image after AT. Consecutively, a full double-image encryption can be achieved by employing classical double random phase encryption (DRPE) technique in the fractional Fourier transform domain with corresponding fractional orders. In this study, the encrypted complex data is randomly sampled via compressive sensing (CS) framework by which only 25% of the sparse white noise samples are being reserved to realize decryption with zero or small errors. As a consequence, together with correct phase keys, fractional orders and proper inverse AT operators, minimization must be utilized to decrypt the original information. Thus, in addition to the perfect image reconstruction, the proposed cryptosystem provides an additional layer of security to the conventional DRPE system. Both the mathematical and numerical simulations were carried out to verify the feasibility as well as the robustness of the proposed system. The simulation results are presented in order to demonstrate the effectiveness of the proposed system. To the best of our knowledge, this is the first report on integrating CS with encrypted complex samples for information security.
In this study, we investigate the integration of compressive sensing (CS) and photon-counting imaging (PCI) techniques with a ptychography-based optical image encryption system. Primarily, the plaintext real-valued image is optically encrypted and recorded via a classical ptychography technique. Further, the sparse-based representations of the original encrypted complex data can be produced by combining CS and PCI techniques with the primary encrypted image. Such a combination takes an advantage of reduced encrypted samples (i.e., linearly projected random compressive complex samples and photon-counted complex samples) that can be exploited to realize optical decryption, which inherently serves as a secret key (i.e., independent to encryption phase keys) and makes an intruder attack futile. In addition to this, recording fewer encrypted samples provides a substantial bandwidth reduction in online transmission. We demonstrate that the fewer sparse-based complex samples have adequate information to realize decryption. To the best of our knowledge, this is the first report on integrating CS and PCI with conventional ptychography-based optical image encryption.