Mohamed Ahmed Azab

Prof. Mohamed Ahmed Azab

Yanbu Industrial College, Yanbu‘, Al Madīnah al Munawwarah, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
MAMohamed Ahmed Azab
Mohamed Ahmed Azab
Ahmed Abu-SiadaAhmed Abu-Siada
Ahmed Abu-Siada
This paper proposes a simple and effective evolutionary computation-based technique to estimate the equivalent circuit parameters of a single-phase transformer from its nameplate data without the need to conduct any experimental measurements. Two techniques, namely: particle swarm optimization and genetic algorithm are employed to track nameplate data by minimizing certain objective functions. The effectiveness of the proposed technique is examined through its application for three single-phase transformers of different ratings. The results show that evolutionary computation techniques can precisely identify transformer equivalent circuit parameters. The proposed technique can be extended to estimate the parameters of a three-phase power transformer from its nameplate data without taking the transformer out of service to carry out any experimental testing.

11 February 2025 in Vehicles
Verified
Journal Article
Open access
PDF file
MAMohamed Ahmed Azab
Mohamed Ahmed Azab
Induction motor (IM) drives are considered one of the important technologies in modern industry. Several industrial applications, such as material handling and food and beverage applications, are driven and operated by modern AC drives. Moreover, modern electric transportation systems such as EVs and e-trucks are based on AC drives. Recently, high-efficiency IM drive systems have been studied as a major opportunity to reduce energy and fuel consumption. This article addresses the recent trends and advancement in high-efficiency IM drives during a particular period (2017–2024), including the development of high-efficiency motors, the utilization of efficient wide bandgap (WBG) semiconductor devices for inverter topology, and commonly used control strategies to achieve high-performance drives. Moreover, the article addresses several manufacturers of industrial IM drives and the corresponding adopted control techniques in their products. A comparison of these control techniques, including their pros and cons, has been conducted as well.

1 January 2021 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
MAMohamed Ahmed Azab
Mohamed Ahmed Azab


Verified
Journal Article
Open access
PDF file
MAMohamed Ahmed Azab
Mohamed Ahmed Azab
The control techniques of the brushless DC (BLDC) motor have gained a large amount of interest in recent years, with their use being implemented in order to achieve a high-performance drive, including quick transient response and high-quality waveforms at the steady state. This paper provides a comparative study between three control schemes of BLDC motors: the direct power control scheme using a finite control set model predictive control (FCS-MPC) approach, the stator current controlled scheme using an FCS-MPC approach, and the stator current controlled scheme using ON–OFF hysteresis current controllers. The three systems were studied and investigated under the same operating conditions. The comparative study included investigating the performance of the BLDC drive in both steady state and transient operations. Qualitative and quantitative analyses were performed on the results obtained with each control scheme. The obtained results demonstrate the validity and effectiveness of the three investigated schemes in controlling the motor speed to the desired value under sudden load changes and achieving satisfactory quick transient responses. However, the results indicate the superiority of the direct power control scheme using an FCS-MPC approach over the others in terms of its minimum torque ripple, lowest torque and speed pulsations, minimum active and reactive power ripples, and high-quality waveforms of the stator currents drawn by the motor with minimum THD.

30 July 2021 in Protection and Control of Modern Power Systems
Verified
Journal Article
Open access
PDF file
MAMohamed Ahmed Azab
Mohamed Ahmed Azab
Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to achieve high-performance decoupled control of the active and reactive powers injected to the grid from distributed energy resources (DER).The FCS-MPC scheme instantaneously searches for and applies the optimum inverter switching state that can achieve certain goals, such as minimum deviation between reference and actual power; so that both power components (P and Q) are well controlled to their reference values.In addition, an effective method to attenuate undesired cross coupling between the P and Q control loops, which occurs only during transient operation, is investigated. The proposed method is based on the variation of the weight factors of the terms of the FCS-MPC cost function, so a higher weight factor is assigned to the cost function term that is exposed to greater disturbance. Empirical formulae of optimum weight factors as functions of the reference active and reactive power signals are proposed and mathematically derived. The investigated FCS-MPC control scheme is incorporated with the LVRT function to support the grid voltage in fulfilling and accomplishing the up-to-date grid codes. The LVRT algorithm is based on a modification of the references of active and reactive powers as functions of the instantaneous grid voltage such that suitable values of P and Q are injected to the grid during voltage sag.The performance of the elaborated FCS-MPC PQ scheme is studied under various operating scenarios, including steady-state and transient conditions. Results demonstrate the validity and effectiveness of the proposed scheme with regard to the achievement of high-performance operation and quick response of grid-tied inverters during normal and fault modes.