Chun Yuan

Chun Yuan


Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2010 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
NBNiranjan Balu
Niranjan Balu
VYVasily L. Yarnykh
Vasily L. Yarnykh
BCBaocheng Chu
Baocheng Chu
JWJinnan Wang
Jinnan Wang
THThomas Hatsukami
Thomas Hatsukami
CYChun Yuan
Chun Yuan
Black‐blood MRI is a promising tool for carotid atherosclerotic plaque burden assessment and compositional analysis. However, current sequences are limited by large slice thickness. Accuracy of measurement can be improved by moving to isotropic imaging but can be challenging for patient compliance due to long scan times. We present a fast isotropic high spatial resolution (0.7 × 0.7 × 0.7 mm3) three‐dimensional black‐blood sequence (3D‐MERGE) covering the entire cervical carotid arteries within 2 min thus ensuring patient compliance and diagnostic image quality. The sequence is optimized for vessel wall imaging of the carotid bifurcation based on its signal properties. The optimized sequence is validated on patients with significant carotid plaque. Quantitative plaque morphology measurements and signal‐to‐noise ratio measures show that 3D‐MERGE provides good blood suppression and comparable plaque burden measurements to existing MRI protocols. 3D‐MERGE is a promising new tool for fast and accurate plaque burden assessment in patients with atherosclerotic plaque. Magn Reson Med, 2011.

13 April 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
KSKarl F. Stupic
Karl F. Stupic
MAMaureen Ainslie
Maureen Ainslie
MBMichael Boss
Michael Boss
CCCecil Charles
Cecil Charles
ADAndrew M. Dienstfrey
Andrew M. Dienstfrey
SRStephen E. Russek
Stephen E. Russek
Purpose: A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal‐to‐noise ratio (SNR), proton‐spin relaxation times, image uniformity and proton density.Methods: The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57‐element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice‐profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T1 and T2 mapping, image resolution, slice profile, and SNR.Results: Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions.Conclusions: A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.

17 October 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
LCLi Chen
Li Chen
MMMahmud Mossa-Basha
Mahmud Mossa-Basha
NBNiranjan Balu
Niranjan Balu
GCGador Canton
Gador Canton
JSJie Sun
Jie Sun
CYChun Yuan
Chun Yuan

14 January 2016 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
MMMahmud Mossa-Basha
Mahmud Mossa-Basha
MAMatthew Alexander
Matthew Alexander
SGSanthosh Gaddikeri
Santhosh Gaddikeri
CYChun Yuan
Chun Yuan
DGDheeraj Gandhi
Dheeraj Gandhi
Accurate and timely diagnosis of intracranial vasculopathies is important owing to the significant risk of morbidity with delayed and/or incorrect diagnosis both from the disease process and inappropriate therapies. Conventional luminal imaging techniques for analysis of intracranial vasculopathies are limited to evaluation of changes in the vessel lumen. Vessel wall MRI techniques can allow direct characterization of pathologic changes of the vessel wall. These techniques may improve diagnostic accuracy and improve patient outcomes. Extracranial carotid vessel wall imaging has been extensively investigated in patients with atherosclerotic disease and has been shown to accurately assess plaque composition and identify vulnerable plaque characteristics that may predict stroke risk beyond luminal stenosis alone. This review provides a brief history of vessel wall MRI, an overview of the intracranial vessel wall MRI techniques, its applications, and imaging findings of various intracranial vasculopathies pertinent to the neurointerventionalist, neurologist, and neuroradiologist. We searched MEDLINE, PubMed, and Google for English publications containing any of the following terms: ‘intracranial vessel wall imaging’, ‘intracranial vessel wall’, and ‘intracranial vessel wall MRI’.

1 January 2015 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
ZZZechen Zhou
Zechen Zhou
RLRui Li
Rui Li
XZXihai Zhao
Xihai Zhao
LHLe He
Le He
XWXiaole Wang
Xiaole Wang
CYChun Yuan
Chun Yuan
Multi-contrast vessel wall cardiovascular magnetic resonance (CMR) has demonstrated its capability for atherosclerotic plaque morphology measurement and component characterization in different vasculatures. However, limited coverage and partial volume effect with conventional two-dimensional (2D) techniques might cause lesion underestimation. The aim of this work is to evaluate the performance in a) blood suppression and b) vessel wall delineation of three-dimensional (3D) multi-contrast joint intra- and extracranial vessel wall imaging at 3T. Three multi-contrast 3D black blood (BB) sequences with T1, T2 and heavy T1 weighting and a custom designed 36-channel neurovascular coil covering the entire intra- and extracranial vasculature have been used and investigated in this study. Two healthy subjects were recruited for sequence parameter optimization and twenty-five patients were consecutively scanned for image quality and blood suppression assessment. Qualitative image scores of vessel wall delineation as well as quantitative Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) were evaluated at five typical locations ranging from common carotid arteries to middle cerebral arteries. The 3D multi-contrast images acquired within 15mins allowed the vessel wall visualization with 0.8 mm isotropic spatial resolution covering intra- and extracranial segments. Quantitative wall and lumen SNR measurements for each sequence showed effective blood suppression at all selected locations (P < 0.0001). Although the wall-lumen CNR varied across measured locations, each sequence provided good or adequate image quality in both intra- and extracranial segments. The proposed 3D multi-contrast vessel wall technique provides isotropic resolution and time efficient solution for joint intra- and extracranial vessel wall CMR.

1 January 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
YXYilan Xu
Yilan Xu
CYChun Yuan
Chun Yuan
ZZZechen Zhou
Zechen Zhou
LHLe He
Le He
DMDonghua Mi
Donghua Mi
XZXihai Zhao
Xihai Zhao
As a systemic disease, atherosclerosis commonly affects intracranial and extracranial carotid arteries simultaneously which is defined as co-existing plaques. Previous studies demonstrated that co-existing atherosclerotic diseases are significantly associated with ischemic cerebrovascular events. The aim of this study was to investigate the characteristics of co-existing intracranial and extracranial carotid atherosclerotic plaques and their relationships with recurrent stroke by using 3D multi-contrast magnetic resonance (MR) vessel wall imaging. Patients with recent cerebrovascular symptoms in anterior circulation and at least one carotid plaque were recruited. All patients underwent cardiovascular magnetic resonance (CMR) for brain and intracranial and extracranial arteries. Presence/absence of atherosclerotic plaque at each arterial segment was identified. The maximum wall thickness (Max WT), length, stenosis of each plaque was measured. The presence/absence of calcification, lipid-rich necrotic core (LRNC), and intraplaque hemorrhage (IPH) was assessed. Cerebral old and acute infarcts in anterior circulation were evaluated. Fifty-eight patients (mean age: 58.0 ± 8.5 years old, 34 males) were recruited. Of the 58 patients, co-existing intracranial and extracranial carotid artery plaques were found in 45 patients (77.6%), of which 7 (15.6%) had first time acute stroke and 26 (57.8%) had recurrent stroke. For these 33 patients with stroke, the number of intracranial plaques (OR = 11.26; 95% CI, 1.27–100; p = 0.030) and co-existing intracranial and extracranial carotid artery plaques (OR = 2.42; 95% CI, 1.04–5.64; p = 0.040) was significantly associated with recurrent stroke. After adjusting for traditional risk factors, the number of co-existing plaques was still significantly correlated with recurrent stroke (OR = 3.31; 95% CI, 1.09–10.08; p = 0.035). No correlations were found between recurrent stroke and Max WT, length, stenosis, and compositions of plaques. Co-existing intracranial and extracranial carotid artery plaques are prevalent in symptomatic patients and the number of co-existing plaques is independently associated with the risk of recurrent stroke.