Yongqiang Kang

Dr. Yongqiang Kang

Lanzhou Jiaotong University, Lanzhou, Gansu, China
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2022 in Coatings
Verified
Journal Article
Open access
PDF file
Shuaibing LiShuaibing Li
Shuaibing Li
XYXingzu Yang
Xingzu Yang
YKYongqiang Kang
Yongqiang Kang
ZLZongying Li
Zongying Li
HLHongwei Li
Hongwei Li
As aerospace, electrified railway, weapon equipment manufacturing, and other fields have leapt forward, the operating environment of current-carrying friction pairs is becoming increasingly severe, and research on the current-carrying friction and wear theory and its vital technologies are progressively in demand. This study summarizes the relevant research on the current-carrying friction and wear. In this study, the essential characteristics and classification of current-carrying friction and wear are summarized, the effect of working parameters on current-carrying friction and wear performance is clarified, and the generation mechanism, failure mechanism, and factors of current-carrying friction and wear are emphatically investigated. Moreover, the mechanism of arc generation and the effect of environmental conditions and surface facial masks on the friction and wear process are summarized. This paper also introduces the preparation technology of a conductive wear-resistant self-lubricating material, the main factors affecting the conductive wear-resistant property of the coating, and the action mechanism. The simulation and prediction results of the current-carrying friction and wear temperature field and the wear amount are presented. Finally, the problems in the current-carrying friction and wear research are classified, and future research directions in this field are proposed. The future’s critical development and improvement directions are also proposed from the aspects of developing coating quality evaluation equipment, optimizing the coating quality, and studying the coating self-lubricating mechanisms.

3 March 2023 in High Voltage
Verified
Journal Article
Open access
Shuaibing LiShuaibing Li
Shuaibing Li
BCBinglei Cao
Binglei Cao
Jin LiJin Li
Jin Li
YCYi Cui
Yi Cui
YKYongqiang Kang
Yongqiang Kang
GWGuangning Wu
Guangning Wu
Composited cable terminals are critical for reliable power delivery of traditional and traction power supply systems. During its operation, the cable terminal continually undergoes complex circumstances where humidity, temperature, field strength, mechanical stress and other factors continuously change at different levels. In extreme cases, defects or even failures may occur in the cable terminals, leading to catastrophic accidents. This makes the condition monitoring and defect detection of composited cable terminals become an imperative need for the power industry. The “state‐of‐the‐art” technology of cable terminal condition assessment is focussed and a systematic review of the current research progress of cable terminal condition assessment from the operation circumstances to failure mechanisms is provided. It covers both online/offline condition monitoring methods and defects detection approaches. In addition, challenges and future research directions for cable terminal condition assessment are also addressed. It is concluded that the non‐destructive and non‐intrusive methods like terahertz imaging and ultrasonic testing, and multi‐source information fusion methods as well as the digital twin technology have been gaining popularity for cable terminal defect inspection. It is expected the presented work can provide a global field of vision for further advancement of both scholars and industrial engineers in this field.

6 October 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Shuaibing LiShuaibing Li
Shuaibing Li
BCBinglei Cao
Binglei Cao
YKYongqiang Kang
Yongqiang Kang
YCYi Cui
Yi Cui
HDHaiying Dong
Haiying Dong
Moisture damp has been identified as one of the most harmful agents of multilayer composited insulation, which can seriously accelerate its degradation, cause unexpected failure, and even lead to catastrophic accidents. This article proposes a nonintrusive method for moisture inspection of multilayer insulation structure based on terahertz (THz) technology with a focus on the cable terminal of the electric multiple units (EMUs). First, a three-layer scattering model is established based on the actual structure of the composite cable terminal, and theoretical analysis is performed to reveal the potential application mechanism. Based on that, an artificial model of a three-layer structure is then built on which the insulation damp test is carried out. Finally, the THz spectrum and THz imaging tests are performed. Results show that the frequency-domain signal can effectively identify the moisture inside the multilayer composited insulation. The imaging results in the frequency domain of the sample can accurately determine the geometric parameters of the damp area. By further analyzing the time-domain spectroscopy, the thickness of insulation affected by moisture can be identified quantitatively. This article verifies the feasibility of THz technology in inspecting the moisture dampness of multilayer composite insulation and its potential application in the damp condition assessment of EMU cable terminals.

18 August 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Shuaibing LiShuaibing Li
Shuaibing Li
BCBinglei Cao
Binglei Cao
YCYi Cui
Yi Cui
YKYongqiang Kang
Yongqiang Kang
SGSheng Gao
Sheng Gao
HDHaiying Dong
Haiying Dong
Cable terminals of the high-speed electric multiple units (EMUs) are prone to undertake insulation delamination defects due to their special operating conditions. Such a defect is difficult to identify and it may pose a great threat to the safety of the EMUs. To achieve accurate detection of insulation delamination defects, this article proposes a terahertz (THz)-based approach that combines the spectrum of the THz wave and THz imaging techniques. Specifically, a synthetic multilayer composite insulation structure with an air gap is firstly built to simulate the internal delamination defect of the cable terminal. Then THz tests in both time and frequency domains are performed on the synthetic structure. Experimental results show that the delamination defect of the multilayer insulation structure can be quickly detected by observing the absorption spectrum in the THz frequency domain. The location and geometry of the defect can be preliminarily determined by the THz imaging and then further refined through image segmentation. In addition, the thickness of the delamination defect can be quickly calculated by the THz time-domain spectrum (TDS). By combining the THz spectrum and the THz imaging information, the delamination defects are quantitatively detected for the multilayer composite structure or even for the EMU’s cable terminals.

28 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
BLbaopeng lu
baopeng lu
Shuaibing LiShuaibing Li
Shuaibing Li
YCYi Cui
Yi Cui
XZXiaowei Zhao
Xiaowei Zhao
DZDaqi Zhang
Daqi Zhang
HDHaiying Dong
Haiying Dong
The marine environment in which offshore wind turbines are located is very complex and subjected to a variety of random loads that vary with time and space. As an important component of offshore wind power, the cable also bears the impact of the environment in which most of the turbines are located. Under the long-term action of mechanical stresses such as tension, torsion, and vibration, the cable insulation will crack due to stress fatigue leading to partial discharge, which seriously affects its electrical performance. The study of the mechanism of the change of electrical properties of cable insulation due to mechanical behavior is of great theoretical guidance to improve the reliable operation of cables. This paper first introduces the basic characteristics and operating conditions of torsion-resistant cables and submarine cables. Then the mechanical behavior of the cables is summarized, and the deterioration mechanism and deterioration effect of wind power cable insulation under the influence of multiple factors such as heat, oxygen, and mechanical stress are sorted out. Then, the basic principles of wind power cable operation condition monitoring methods and their characteristics are described. Finally, the relevant methods for the detection of hidden defects inside the insulation are summarized.

15 August 2017 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
YKYongqiang Kang
Yongqiang Kang
XZXueqin Zhang
Xueqin Zhang
CSChaoqun Shi
Chaoqun Shi
YZYue Zhou
Yue Zhou
YLYijie Liu
Yijie Liu
GWGuangning Wu
Guangning Wu
To understand the flashover of roof insulators in high-speed airflows, the breakdown characteristics and mechanisms of a short needle-plate air gap are investigated. An interesting and important phenomenon is found based on an artificial wind tunnel: the breakdown voltage first increases and then decreases. An experiential formula is established to describe the relationship among the airflow velocity, gap distance, and breakdown voltage. A good consistency with the experimental results is obtained. Furthermore, the breakdown mechanisms of the air gap in high-speed airflows are proposed, and the phenomenon is explained and verified according to the theories of gas discharge and fluid dynamics. The airflow blowing effect, which includes the deflection effect and blown away effect, and the airflow density effect are proposed as two dominant factors that affect the breakdown process of the air gap in high-speed airflows. The variation trend of the breakdown voltage with the airflow velocity is predicted. Two extreme points are expected during the variation process; i.e., the breakdown voltage has a maximum and a minimum, to which more attention should be paid. This paper is helpful for the safety operation of roof insulators on the high-speed train.