This study explores the impact of high-photovoltaic (PV) penetration on the inter-area oscillation modes of large-scale power grids. A series of dynamic models with various PV penetration levels are developed based on a detailed model representing the U.S. Eastern Interconnection (EI). Transient simulations are performed to investigate the change of inter-area oscillation modes with PV penetration. The impact of PV control strategies and parameter settings on inter-area oscillations is studied. This paper finds that as PV increases, the damping of the dominant oscillation mode decreases monotonically. It is also observed that the mode shape varies with the PV control strategy and new oscillation modes may emerge under inappropriate parameter settings in PV plant controls.
26 August 2014 in IEEE Transactions on Power Delivery
In this paper, we present an update to the models used to calculate the remaining life of transformer paper insulation. A drawback to the current IEEE method is that it does not take into account the availability of water and oxygen on the life expectancy of Kraft paper insulation. We therefore set out to test an algorithm which does take these into account. For our investigation, we loaded three test transformers and ran them to near their end of life. Kinetic equations were applied to model the fall in the degree of polymerization of paper. Our model showed better agreement with the test results than that given from using the IEEE standard. The IEEE standard gives life expectancy for Kraft paper being aged in minimal oxygen under dry conditions, which is not necessarily representative of an old transformer. Wet paper and using high levels of oxygen can age nearly 40 times faster. The IEEE method needs to take the synergistic effect of water and oxygen on increasing the rate of paper aging into account.
The distribution-level electric network frequency (ENF) extracted from an electric power signal is a promising forensic tool for multimedia recording authentication. Local characteristics in ENF signals recorded in different locations act as environmental signatures, which can be potentially used as a fingerprint for location identification. In this paper, a reference database is established for distribution-level ENF using FNET/GridEye system. An ENF identification method that combines a wavelet-based signature extraction and feedforward artificial neural network-based machine learning is presented to identify the location of unsourced ENF signals without relying on the availability of concurrent signals. Experiments are performed to validate the effectiveness of the proposed method using ambient frequency measurements at multiple geographic scales. Identification accuracy is presented, and the factors that affect identification performance are discussed.
The wide area monitoring system (WAMS) is considered a pivotal component of future electric power grids. As a pilot WAMS that has been operated for more than a decade, the frequency monitoring network FNET/GridEye makes use of hundreds of global positioning system-synchronized phasor measurement sensors to capture the increasingly complicated grid behaviors across the interconnected power systems. In this paper, the FNET/GridEye system is overviewed and its operation experiences in electric power grid wide area monitoring are presented. Particularly, the implementation of a number of data analytics applications will be discussed in details. FNET/GridEye lays a firm foundation for the later WAMS operation in the electric power industry.
Composited cable terminals are critical for reliable power delivery of traditional and traction power supply systems. During its operation, the cable terminal continually undergoes complex circumstances where humidity, temperature, field strength, mechanical stress and other factors continuously change at different levels. In extreme cases, defects or even failures may occur in the cable terminals, leading to catastrophic accidents. This makes the condition monitoring and defect detection of composited cable terminals become an imperative need for the power industry. The “state‐of‐the‐art” technology of cable terminal condition assessment is focussed and a systematic review of the current research progress of cable terminal condition assessment from the operation circumstances to failure mechanisms is provided. It covers both online/offline condition monitoring methods and defects detection approaches. In addition, challenges and future research directions for cable terminal condition assessment are also addressed. It is concluded that the non‐destructive and non‐intrusive methods like terahertz imaging and ultrasonic testing, and multi‐source information fusion methods as well as the digital twin technology have been gaining popularity for cable terminal defect inspection. It is expected the presented work can provide a global field of vision for further advancement of both scholars and industrial engineers in this field.
17 December 2020 in IEEE Transactions on Smart Grid
The declining cost of solar Photovoltaics (PV) generation is driving its worldwide deployment. As conventional generation with large rotating masses is being replaced by renewable energy such as PV, the power system’s inertia will be affected. As a result, the system’s frequency may vary more dramatically in the case of a disturbance, and the frequency nadir may be low enough to trigger protection relays such as under-frequency load shedding. The existing frequency-watt function mandated in power inverters cannot provide grid frequency support in a loss-of-generation event, as PV plants usually do not have power reserves. In this article, a novel adaptive PV frequency control strategy is proposed to reserve the minimum power required for grid frequency support. A machine learning model is trained to predict system frequency response under varying system conditions, and an adaptive allocation of PV headroom reserves is made based on the machine learning model as well as real-time system conditions including inertia. Case studies show the proposed control method meets the frequency nadir requirements using minimal power reserves compared to a fixed headroom control approach.