Ye Tian

Ye Tian


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
YWYanchao Wang
Yanchao Wang
YTYe Tian
Ye Tian
HSHaotian She
Haotian She
YJYinlai Jiang
Yinlai Jiang
HYHiroshi Yokoi
Hiroshi Yokoi
YLYunhui Liu
Yunhui Liu
In this paper, we develop a prosthetic bionic hand system to realize adaptive gripping with two closed-loop control loops by using a linear discriminant analysis algorithm (LDA). The prosthetic hand contains five fingers and each finger is driven by a linear servo motor. When grasping objects, four fingers except the thumb would adjust automatically and bend with an appropriate gesture, while the thumb is stretched and bent by the linear servo motor. Since the change of the surface electromechanical signal (sEMG) occurs before human movement, the recognition of sEMG signal with LDA algorithm can help to obtain people’s action intention in advance, and then timely send control instructions to assist people to grasp. For activity intention recognition, we extract three features, Variance (VAR), Root Mean Square (RMS) and Minimum (MIN) for recognition. As the results show, it can achieve an average accuracy of 96.59%. This helps our system perform well for disabilities to grasp objects of different sizes and shapes adaptively. Finally, a test of the people with disabilities grasping 15 objects of different sizes and shapes was carried out and achieved good experimental results.

5 January 2022 in Neural Computing and Applications
Verified
Journal Article
Closed access
PDF file
XLXiaodong Lv
Xiaodong Lv
CDChuankai Dai
Chuankai Dai
HLHaijie Liu
Haijie Liu
YTYe Tian
Ye Tian
LCLuyao Chen
Luyao Chen
JHJiping He
Jiping He

14 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HSHaotian She
Haotian She
JZJinying Zhu
Jinying Zhu
YTYe Tian
Ye Tian
WYWang Yanchao
Wang Yanchao
HYHiroshi Yokoi
Hiroshi Yokoi
QHQiang Huang
Qiang Huang
Feature extraction, as an important method for extracting useful information from surface electromyography (SEMG), can significantly improve pattern recognition accuracy. Time and frequency analysis methods have been widely used for feature extraction, but these methods analyze SEMG signals only from the time or frequency domain. Recent studies have shown that feature extraction based on time-frequency analysis methods can extract more useful information from SEMG signals. This paper proposes a novel time-frequency analysis method based on the Stockwell transform (S-transform) to improve hand movement recognition accuracy from forearm SEMG signals. First, the time-frequency analysis method, S-transform, is used for extracting a feature vector from forearm SEMG signals. Second, to reduce the amount of calculations and improve the running speed of the classifier, principal component analysis (PCA) is used for dimensionality reduction of the feature vector. Finally, an artificial neural network (ANN)-based multilayer perceptron (MLP) is used for recognizing hand movements. Experimental results show that the proposed feature extraction based on the S-transform analysis method can improve the class separability and hand movement recognition accuracy compared with wavelet transform and power spectral density methods.

17 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YWYanchao Wang
Yanchao Wang
YTYe Tian
Ye Tian
JZJinying Zhu
Jinying Zhu
HSHaotian She
Haotian She
HYHiroshi Yokoi
Hiroshi Yokoi
QHQiang Huang
Qiang Huang
Myoelectric prosthesis has become an important aid to disabled people. Although it can help people to recover to a nearly normal life, whether they can adapt to severe working conditions is a subject that is yet to be studied. Generally speaking, the working environment is dominated by vibration. This paper takes the gripping action as its research object, and focuses on the identification of grasping intentions under different vibration frequencies in different working conditions. In this way, the possibility of the disabled people who wear myoelectric prosthesis to work in various vibration environment is studied. In this paper, an experimental test platform capable of simulating 0–50 Hz vibration was established, and the Surface Electromyography (sEMG) signals of the human arm in the open and grasping states were obtained through the MP160 physiological record analysis system. Considering the reliability of human intention recognition and the rapidity of algorithm processing, six different time-domain features and the Linear Discriminant Analysis (LDA) classifier were selected as the sEMG signal feature extraction and recognition algorithms in this paper. When two kinds of features, Zero Crossing (ZC) and Root Mean Square (RMS), were used as input, the accuracy of LDA algorithm can reach 96.9%. When three features, RMS, Minimum Value (MIN), and Variance (VAR), were used as inputs, the accuracy of the LDA algorithm can reach 98.0%. When the six features were used as inputs, the accuracy of the LDA algorithm reached 98.4%. In the analysis of different vibration frequencies, it was found that when the vibration frequency reached 20 Hz, the average accuracy of the LDA algorithm in recognizing actions was low, while at 0 Hz, 40 Hz and 50 Hz, the average accuracy was relatively high. This is of great significance in guiding disabled people to work in a vibration environment in the future.

6 April 2020 in Advanced Robotics
Verified
Journal Article
Closed access
HSHaotian She
Haotian She
JZJinying Zhu
Jinying Zhu
YTYe Tian
Ye Tian
YWYanchao Wang
Yanchao Wang
QHQiang Huang
Qiang Huang
This paper proposes a powered ankle-foot prosthesis called PANTOE II, which includes an ankle and a segmented foot with a toe joint. The ankle and toe joints are both driven by series elastic actuators, which can reduce the required velocity and energy consumption of the actuators. The mechanical design of the ankle and toe joints makes the prosthesis more compact. In addition, PANTOE II employs a more human-like foot, which includes the heel, the mid foot, and the toe. Both the heel and the toe are made of leaf springs, and the mid foot is used to install the transmission mechanisms. The finite state control strategy is used for controlling the prosthesis. To evaluate the basic performance of PANTOE II, experiments are conducted on a subject with a transtibial amputation. Wearing PANTOE II, the amputee feels more comfortable and presents more symmetrical walking gaits.

22 May 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
YWYuxuan Wang
Yuxuan Wang
YTYe Tian
Ye Tian
ZLZhenyu Li
Zhenyu Li
HSHaotian She
Haotian She
ZJZhihong Jiang
Zhihong Jiang
In order to solve the problems of methods that use a single form of sensing, the ease of causing deformation damage to the targets with a low hardness during grasping, and the slow sliding inhibition of a prosthetic hand when the grasping target slides, which are problems that exist in most current intelligent prosthetic hands, this study introduces an adaptive control strategy for prosthetic hands based on multi-sensor sensing. Using a force-sensing resistor (FSR) to collect changes in signals generated after contact with a target, a prosthetic hand can classify the target’s hardness level and adaptively provide the desired grasping force so as to reduce the deformation of and damage to the target in the process of grasping. A fiber-optic sensor collects the light reflected by the object to identify its surface roughness, so that the prosthetic hand adaptively adjusts the sliding inhibition method according to the surface roughness information to improve the grasping efficiency. By integrating information on the hardness and surface roughness of the target, an adaptive control strategy for a prosthetic hand is proposed. The experimental results showed that the adaptive control strategy was able to reduce the damage to the target by enabling the prosthetic hand to achieve stable grasping; after grasping the target with an initial force and generating sliding, the efficiency of slippage inhibition was improved, the target could be stably grasped in a shorter time, and the hardness, roughness and weight ranges of targets that could be grasped by the prosthetic hand were enlarged, thus improving the success rate of stable grasping under extreme conditions.