This paper reports on a microelectromechanical systems (MEMS)-based sensor for pulse wave measurement. The sensor consists of an air chamber with a thin membrane and a 300-nm thick piezoresistive cantilever placed inside the chamber. When the membrane of the chamber is in contact with the skin above a vessel of a subject, the pulse wave of the subject causes the membrane to deform, leading to a change in the chamber pressure. This pressure change results in bending of the cantilever and change in the resistance of the cantilever, hence the pulse wave of the subject can be measured by monitoring the resistance of the cantilever. In this paper, we report the sensor design and fabrication, and demonstrate the measurement of the pulse wave using the fabricated sensor. Finally, measurement of the pulse wave velocity (PWV) is demonstrated by simultaneously measuring pulse waves at two points using the two fabricated sensor devices. Furthermore, the effect of breath holding on PWV is investigated. We showed that the proposed sensor can be used to continuously measure the PWV for each pulse, which indicates the possibility of using the sensor for continuous blood pressure measurement.

13 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NTNguyen Thanh-Vinh
Nguyen Thanh-Vinh
MIMasaaki Ichiki
Masaaki Ichiki
The continuous measurements of vital signs (body temperature, blood pressure, pulse wave, and respiration rate) are important in many applications across various fields, including healthcare and sports. To realize such measurements, wearable devices that cause minimal discomfort to the wearers are highly desired. Accordingly, a device that can measure multiple vital signs simultaneously using a single sensing element is important in order to reduce the number of devices attached to the wearer’s body, thereby reducing user discomfort. Thus, in this study, we propose a device with a microelectromechanical systems (MEMS)-based pressure sensor that can simultaneously measure the blood pulse wave and respiration rate using only one sensing element. In particular, in the proposed device, a thin silicone tube, whose inner pressure can be measured via a piezoresistive cantilever, is attached to the nose pad of a pair of eyeglasses. On wearing the eyeglasses, the tube of sensor device is in contact with the area above the angular artery and nasal cavity of the subject, and thus, both pulse wave and breath of the subject cause the tube’s inner pressure to change. We experimentally show that it is possible to extract information related to pulse wave and respiration as the low-frequency and high-frequency components of the sensor signal, respectively.

29 June 2020 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
NTNguyen Thanh-Vinh
Nguyen Thanh-Vinh
MIMasaaki Ichiki
Masaaki Ichiki
When a droplet impacts a (super-)hydrophobic surface, there is a range of Weber numbers within which bubble entrapment will occur during droplet recoil due to closure of the air cavity developed when the droplet spreads out during the impact. In this study, we studied bubble entrapment using a microelectromechanical system (MEMS)-based acoustic sensor fabricated on a substrate. We found that bubble entrapment is followed by an acoustic vibration that can be detected by the sensor. Moreover, the frequency of the vibration is inversely proportional to the radius of the droplet, which indicates that this vibration is the resonant oscillation of the bubble. Therefore, the MEMS-based acoustic sensor can be used not only to detect but also to measure the size of the entrapped bubble. Finally, we demonstrated that it is possible to prevent bubble formation by allowing the air to escape to the underside of the droplet contact area. This can be done by creating through-holes on the substrate or decorating the substrate with sufficiently large textures.

19 April 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
TNTaiga Nabeshima
Taiga Nabeshima
NTNguyen Thanh-Vinh
Nguyen Thanh-Vinh
HTHidetoshi Takahashi
Hidetoshi Takahashi
Wearable sensor devices with minimal discomfort to the wearer have been widely developed to realize continuous measurements of vital signs (body temperature, blood pressure, respiration rate, and pulse wave) in many applications across various fields, such as healthcare and sports. Among them, microelectromechanical systems (MEMS)-based differential pressure sensors have garnered attention as a tool for measuring pulse waves with weak skin tightening. Using a MEMS-based piezoresistive cantilever with an air chamber as the pressure change sensor enables highly sensitive pulse-wave measurements to be achieved. Furthermore, the initial static pressure when attaching the sensor to the skin is physically excluded because of air leakage around the cantilever, which serves as a high-pass filter. However, if the frequency characteristics of this mechanical high-pass filter are not appropriately designed, then the essential information of the pulse-wave measurement may not be reflected. In this study, the frequency characteristics of a sensor structure is derived theoretically based on the air leakage rate and chamber size. Subsequently, a pulse wave sensor with a MEMS piezoresistive cantilever element, two air chambers, and a skin-contacted membrane is designed and fabricated. The developed sensor is 30 mm in diameter and 8 mm in thickness and realizes high-pass filter characteristics of 0.7 Hz. Finally, pulse wave measurement at the neck of a participant is demonstrated using the developed sensor. It is confirmed that the measured pulse wave contains signals in the designed frequency band.

19 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
NTNguyen Thanh-Vinh
Nguyen Thanh-Vinh
MIMasaaki Ichiki
Masaaki Ichiki
This paper reports on a mask-type sensor for simultaneous pulse wave and respiration measurements and eye blink detection that uses only one sensing element. In the proposed sensor, a flexible air bag-shaped chamber whose inner pressure change can be measured by a microelectromechanical system-based piezoresistive cantilever was used as the sensing element. The air bag-shaped chamber is fabricated by wrapping a sponge pad with plastic film and polyimide tape. The polyimide tape has a hole to which the substrate with the piezoresistive cantilever adheres. By attaching the sensor device to a mask where it contacts the nose of the subject, the sensor can detect the pulses and eye blinks of the subject by detecting the vibration and displacement of the nose skin caused by these physiological parameters. Moreover, the respiration of the subject causes pressure changes in the space between the mask and the face of the subject as well as slight vibrations of the mask. Therefore, information about the respiration of the subject can be extracted from the sensor signal using either the low-frequency component (100 Hz). This paper describes the sensor fabrication and provides demonstrations of the pulse wave and respiration measurements as well as eye blink detection using the fabricated sensor.