Tomoyuki Takahata

Prof. Tomoyuki Takahata

The University of Tokyo
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2010 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
STSeiichi Takamatsu
Seiichi Takamatsu
TTTomoyuki Takahata
Tomoyuki Takahata
MMMasato Muraki
Masato Muraki
EIEiji Iwase
Eiji Iwase
KMKiyoshi Matsumoto
Kiyoshi Matsumoto
ISIsao Shimoyama
Isao Shimoyama

15 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
NTNguyen Thanh-Vinh
Nguyen Thanh-Vinh
YMYuya Mizuki
Yuya Mizuki
TTTakuya Tsukagoshi
Takuya Tsukagoshi
TTTomoyuki Takahata
Tomoyuki Takahata
MIMasaaki Ichiki
Masaaki Ichiki
ISIsao Shimoyama
Isao Shimoyama
This paper reports on a microelectromechanical systems (MEMS)-based sensor for pulse wave measurement. The sensor consists of an air chamber with a thin membrane and a 300-nm thick piezoresistive cantilever placed inside the chamber. When the membrane of the chamber is in contact with the skin above a vessel of a subject, the pulse wave of the subject causes the membrane to deform, leading to a change in the chamber pressure. This pressure change results in bending of the cantilever and change in the resistance of the cantilever, hence the pulse wave of the subject can be measured by monitoring the resistance of the cantilever. In this paper, we report the sensor design and fabrication, and demonstrate the measurement of the pulse wave using the fabricated sensor. Finally, measurement of the pulse wave velocity (PWV) is demonstrated by simultaneously measuring pulse waves at two points using the two fabricated sensor devices. Furthermore, the effect of breath holding on PWV is investigated. We showed that the proposed sensor can be used to continuously measure the PWV for each pulse, which indicates the possibility of using the sensor for continuous blood pressure measurement.

18 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
TOTaiyu Okatani
Taiyu Okatani
HTHidetoshi Takahashi
Hidetoshi Takahashi
KNKentaro Noda
Kentaro Noda
TTTomoyuki Takahata
Tomoyuki Takahata
KMKiyoshi Matsumoto
Kiyoshi Matsumoto
ISIsao Shimoyama
Isao Shimoyama
This paper reports on a tactile sensor using piezoresistive beams for detection of the coefficient of static friction merely by pressing the sensor against an object. The sensor chip is composed of three pairs of piezoresistive beams arranged in parallel and embedded in an elastomer; this sensor is able to measure the vertical and lateral strains of the elastomer. The coefficient of static friction is estimated from the ratio of the fractional resistance changes corresponding to the sensing elements of vertical and lateral strains when the sensor is in contact with an object surface. We applied a normal force on the sensor surface through objects with coefficients of static friction ranging from 0.2 to 1.1. The fractional resistance changes corresponding to vertical and lateral strains were proportional to the applied force. Furthermore, the relationship between these responses changed according to the coefficients of static friction. The experimental result indicated the proposed sensor could determine the coefficient of static friction before a global slip occurs.

12 September 2017 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
KMKenei Matsudaira
Kenei Matsudaira
TNThanh Vinh Nguyen
Thanh Vinh Nguyen
KSKayoko Hirayama Shoji
Kayoko Hirayama Shoji
TTTakuya Tsukagoshi
Takuya Tsukagoshi
TTTomoyuki Takahata
Tomoyuki Takahata
ISIsao Shimoyama
Isao Shimoyama
This paper reports on a method to directly measure the contractile forces of cardiomyocytes using MEMS (micro electro mechanical systems)-based force sensors. The fabricated sensor chip consists of piezoresistive cantilevers that can measure contractile forces with high frequency (several tens of kHz) and high sensing resolution (less than 0.1 nN). Moreover, the proposed method does not require a complex observation system or image processing, which are necessary in conventional optical-based methods. This paper describes the design, fabrication, and evaluation of the proposed device and demonstrates the direct measurements of contractile forces of cardiomyocytes using the fabricated device.

1 March 2019 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
HTHidetoshi Takahashi
Hidetoshi Takahashi
TKTetsuo Kan
Tetsuo Kan
ANAkihito Nakai
Akihito Nakai
TTTomoyuki Takahata
Tomoyuki Takahata
TUTakanori Usami
Takanori Usami
ISIsao Shimoyama
Isao Shimoyama

21 June 2011 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
STSeiichi Takamatsu
Seiichi Takamatsu
TTTomoyuki Takahata
Tomoyuki Takahata
KMKiyoshi Matsumoto
Kiyoshi Matsumoto
ISIsao Shimoyama
Isao Shimoyama