Elena Colombini

Dr. Elena Colombini

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Materials Chemistry and Physics
Verified
Journal Article
Open access
Elena ColombiniElena Colombini
Elena Colombini
Roberto RosaRoberto Rosa
Roberto Rosa
LTL. Trombi
L. Trombi
MZM. Zadra
M. Zadra
ACA. Casagrande
A. Casagrande
PVPaolo Veronesi
Paolo Veronesi
The aim of this work was to investigate the field assisted powder metallurgy route for producing HEAs at equimolar composition, i.e. FeCoNiCrAl, starting from metal powders. Both mixed, mechanically activated and mechanically alloyed powders have been used. The powders obtained by mechanical alloying were synthesized only by SPS, whereas the remaining ones were sintered by SPS or microwave heating. The investigated field assisted sintering techniques allowed an extremely short alloying time, high energy density on the load and negligible contamination by the surrounding environment. Both the conducted sintering-synthesis technology resulted not definitive to produce chemical homogeneity and to obtain a single stable structure. Thus a subsequently heat treatment was required. The post heat treatment, indeed, led to a single crystalline structure (FCC) and the material was fully recrystallized. After heat treatment samples are isomorphic: they exhibit two different phases with the same FCC cell, but different chemical composition, in detail Fe-Cr richer and Al-Ni richer. SPS-ed samples present a reduced porosity, while microwave processed ones are much more porous and this is reflected in the mechanical properties

1 September 2013 in Journal of the European Ceramic Society
Verified
Journal Article
Closed access
Roberto RosaRoberto Rosa
Roberto Rosa
PVPaolo Veronesi
Paolo Veronesi
SHShahoua Han
Shahoua Han
VCValentina Casalegno
Valentina Casalegno
Milena SalvoMilena Salvo
Milena Salvo
MFMonica Ferraris
Monica Ferraris

19 March 2019 in Coatings
Verified
Journal Article
Open access
PDF file
Michelina CatauroMichelina Catauro
Michelina Catauro
Federico BarrinoFederico Barrino
Federico Barrino
MBMassimiliano Bononi
Massimiliano Bononi
Elena ColombiniElena Colombini
Elena Colombini
Roberto GiovanardiRoberto Giovanardi
Roberto Giovanardi
Elisabetta TranquilloElisabetta Tranquillo
Elisabetta Tranquillo
The use of metallic materials as implants presents some major drawbacks, such as their harmful effects on the living organism, especially those induced by corrosion. To overcome this problem, the implant surface of titanium implants can be improved using a coating of bioactive and biocompatible materials. The aim of this work is the synthesis of SiO2/ZrO2 composites with different percentages of zirconia matrix (20, 33 and 50 wt.%), by the sol-gel method to coat commercial Grade 4 titanium disks using a dip coater. Attenuated total reflectance Fourier transform infrared (ATR/FTIR) spectroscopy was used to evaluate the interactions between the inorganic matrices. Furthermore, the mechanical properties and corrosive behavior of the SiO2/ZrO2 coatings were evaluated as a function of the ZrO2 content. The bioactive properties of the substrate coated with different composites were evaluated using simulated body fluid (SBF). The antibacterial activity was tested against gram-negative and gram-positive Escherichia coli and Enterococcus faecalis, respectively, to assess the release of toxic products from the different composites and to evaluate the possibility of using them in the biomedical field.

1 January 2016 in Materials Letters
Verified
Journal Article
Closed access
PVPaolo Veronesi
Paolo Veronesi
Elena ColombiniElena Colombini
Elena Colombini
Roberto RosaRoberto Rosa
Roberto Rosa
Cristina LeonelliCristina Leonelli
Cristina Leonelli
FRFabrizio Rosi
Fabrizio Rosi

1 December 2017 in Chemical Engineering and Processing - Process Intensification
Verified
Journal Article
Open access
PVPaolo Veronesi
Paolo Veronesi
Elena ColombiniElena Colombini
Elena Colombini
Roberto RosaRoberto Rosa
Roberto Rosa
Cristina LeonelliCristina Leonelli
Cristina Leonelli
MGMarco Garuti
Marco Garuti
Microwaves at the ISM frequency of 2450 and 5800 MHz have been exploited to prepare FeCoNiCrAl-\ud family high entropy alloys by direct heating of pressed mixtures of metal powders. The aim of this work is\ud to explore a new microwave assisted near-net-shape technology, using powder metallurgy approach for\ud the preparation of high entropy alloys, able to overcome the limits of current melting technologies\ud (defects formation) or solid state ones (time demanding). Results show that direct microwave heating of\ud the powder precursors occurs, and further heating generation is favored by the ignition of exothermal\ud reactions in the compound. Microwave processing, exploited both for the ignition and sustaining of such\ud reactions, has been compared to reactive sintering in laboratory furnace and mechanical alloying in a\ud planetary ball milling. Results demonstrate that microwave required the shortest time and lowest energy\ud consumption, thus it is promising time- and cost-saving synthetic route

24 May 2012 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
GCGrace D. Chen
Grace D. Chen
FFFabio Fachin
Fabio Fachin
Elena ColombiniElena Colombini
Elena Colombini
BWBrian L. Wardle
Brian L. Wardle
MTMehmet Toner
Mehmet Toner
The ability to control cell-surface interactions in order to achieve binding of specific cell types is a major challenge for microfluidic immunoaffinity cell capture systems. In the majority of existing systems, the functionalized capture surface is constructed of solid materials, where flow stagnation at the solid-liquid interface is detrimental to the convection of cells to the surface. We study the use of ultra-high porosity (99%) nanoporous micro-posts in microfluidic channels for enhancing interception efficiency of particles in flow. We show using both modelling and experiment that nanoporous posts improve particle interception compared to solid posts through two distinct mechanisms: the increase of direct interception, and the reduction of near-surface hydrodynamic resistance. We provide initial validation that the improvement of interception efficiency also results in an increase in capture efficiency when comparing nanoporous vertically aligned carbon nanotube (VACNT) post arrays with solid PDMS post arrays of the same geometry. Using both bacteria (∼1 μm) and cancer cell lines (∼15 μm) as model systems, we found capture efficiency increases by 6-fold and 4-fold respectively. The combined model and experimental platform presents a new generation of nanoporous microfluidic devices for cell isolation.