Chellapandian Maheswaran

Dr. Chellapandian Maheswaran

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

22 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Arunachelam NakarajanArunachelam Nakarajan
Arunachelam Nakarajan
JMJeyaprakash Maheswaran
Jeyaprakash Maheswaran
Chellapandian MaheswaranChellapandian Maheswaran
Chellapandian Maheswaran
Murali GunasekaranMurali Gunasekaran
Murali Gunasekaran
Nikolai Ivanovich VatinNikolai Ivanovich Vatin
Nikolai Ivanovich Vatin
The present work investigates the mechanical and chemical characteristics and durability of high-strength geopolymer concrete (HSGPC) developed using high-volume copper slag and micro silica. The objective of the study was to explore the feasibility of deploying high-volume copper slag as a replacement for river sand in the fabrication of high-strength geopolymer concrete. In total, 11 different trials were cast by varying copper slag up to 100% as a potential alternative for the river sand. The mixture of alkaline activators for the preparation of the geopolymer concrete (GPC), such as sodium silicate (Na2SiO3) and sodium hydroxide (12 M NaOH), was used in the ratio 2.5:1. The optimum mix was selected from different copper slag dosages based on the characteristics of the HSGPC, such as mechanical strength and workability. For the selected optimized mix, micro silica was added up to 5% by volume of the binder (i.e., 1%, 2%, 3%, 4% and 5%) to improve the particle packing density of the developed HSGPC mix which in turn further enhances the strength and durability properties. Two different curing methods, including (a) ambient curing and (b) steam curing at 80 °C, were deployed for achieving the polymerization reaction (i.e., the formation of Na-Al-Si-H gel). Experimental outcomes reveal a maximum compressive strength of 79.0 MPa when 2% micro silica was added to the optimized GPC mix. In addition to the mechanical tests, the quality of the developed HSGPC was assessed using the ultrasonic pulse velocity (UPV) tests, water-absorption tests, sorptivity tests and microstructural analyses.

14 February 2024 in Journal of Energy Storage
Verified
Journal Article
Closed access
SPSelvan Pugalenthi
Selvan Pugalenthi
Chellapandian MaheswaranChellapandian Maheswaran
Chellapandian Maheswaran
JDJones Joseph Jebaraj Dharmaraj
Jones Joseph Jebaraj Dharmaraj
JDJebakani Devaraj
Jebakani Devaraj
NANakarajan Arunachelam
Nakarajan Arunachelam
SSSeeni Bright Singh
Seeni Bright Singh

1 July 2020 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
PDF file
ADAmal Dev
Amal Dev
Chellapandian MaheswaranChellapandian Maheswaran
Chellapandian Maheswaran
SPSuriya Prakash
Suriya Prakash
Design of reinforced concrete (RC) bridge members with fiber-reinforced polymer (FRP) bars as internal reinforcement are usually governed by their serviceability parameters, such as crack width and deflection. This study investigates the effect of structural fibers on the shear behavior of RC beams with glass fiber-reinforced polymer (GFRP) rebar as longitudinal reinforcement. The objective of this study is to understand the efficiency of macrosynthetic polyolefin (PO) polymer and a hybrid combination of steel and PO fibers in improving the shear behavior of GFRP-reinforced beams. In total, 13 full-scale RC beams are cast with GFRP rebars as internal reinforcement and varying PO and hybrid fiber dosages. Three different fiber dosages by volume of concrete (vf), namely 0.35%, 0.70%, and 1.0% are considered. The beams are tested under three-point bending configuration with a shear span (a) to effective depth (d) ratio of 2.2 to simulate shear dominant behavior. Experimental results revealed that the addition of fibers increased the postcracking stiffness, peak load, and ductility when compared with control beams with no fibers. Soon after cracking, an excessive load drop in the control specimen is observed due to the low elastic modulus of GFRP rebars. The addition of PO and hybrid fibers reduced the load drop significantly and enhanced the postcracking performance by improving the aggregate interlock and through reduction of residual tensile stresses at the crack tip. The angle of the crack increased with an increase in fiber dosages, indicating the change of the failure mode from brittle shear tension to ductile flexure at higher fiber dosages (0.7% and 1.0%). The shear strength predictions obtained from ACI and RILEM recommendations are found to be very conservative when compared with the test results.

14 October 2019 in Fibers
Verified
Journal Article
Open access
PDF file
Chellapandian MaheswaranChellapandian Maheswaran
Chellapandian Maheswaran
SJSaumitra Jain
Saumitra Jain
SPSuriya Prakash
Suriya Prakash
Akanshu SharmaAkanshu Sharma
Akanshu Sharma
The effectiveness of hybrid fibre-reinforced polymer (FRP) strengthening is evaluated for rapid repair of the pre-damaged plain concrete (PC) and reinforced concrete (RC) columns. The objective of this study is to understand the efficiency of hybrid technique for completely restoring the initial stiffness, load carrying capacity and ductility of pre-damaged columns under cyclic compression loads. Two series of PC and RC square columns were cast. The columns were pre-damaged by loading up to 80% of peak load capacity for three cycles under pure compression. After cyclic damage, the columns were strengthened with two techniques, namely (a) near-surface mounted (NSM) carbon FRP (CFRP) laminates and (b) hybrid FRP technique, which uses a combination of NSM and externally bonded (EB) CFRP fabric. Analytical modelling was carried out for predicting the behaviour of columns with initial cyclic pre-damage. Additionally, a phased three-dimensional nonlinear finite element (FE) analysis was performed to validate the behaviour of pre-damaged columns with different strengthening techniques. Test results show that cyclic pre-loading and resulting damage causes a reduction in axial stiffness of all damaged specimens. Hybrid strengthening completely restored the stiffness and strength under compression. Prediction of analytical and FE analysis correlated well with the tests.

1 August 2019 in Journal of Composites for Construction
Verified
Journal Article
Closed access
Chellapandian MaheswaranChellapandian Maheswaran
Chellapandian Maheswaran
SPSuriya Prakash
Suriya Prakash
ASAkanshu Sharma
Akanshu Sharma
This research work presents the interaction behavior of square reinforced concrete (RC) columns strengthened with different fiber-reinforced polymer (FRP) techniques, namely, near-surface mounting (NSM), external bonding (EB), and hybrid strengthening (HYB). Hybrid FRP strengthening uses a combination of near-surface mounted FRP laminates, confined laterally using externally bonded FRP composites, to achieve significant improvement in the peak strength and ductility under all combinations of axial compression (P) and bending (M) loads. Different levels of eccentricity (e ) normalized to the depth (h ) were considered, such as (1) axial compression (e/h=0 ), (2) low-eccentricity compression (e/h=0.15 ), (3) high-eccentricity compression (e/h=0.63 ), and (4) pure bending (e/h=∞ ). A normalized axial compression–bending interaction diagram for the tested columns was developed based on the test results. Experimental results reveal that hybrid FRP strengthening of columns improves the peak strength considerably under all loading combinations of axial compression and bending. In hybrid specimens, bond failure of NSM-strengthened RC elements was prevented through the effective lateral confinement provided by EB carbon fiber–reinforced polymer (CFRP) fabric. The axial compression–bending interaction diagram was analytically derived using a strain compatibility procedure. Analytical predictions exhibited good correlation with the test results for all strengthening techniques.