The ever-increasing need for portable, easy-to-use, cost-effective, and connected point-of-care diagnostics (POCD) has been one of the main drivers of recent research on lab-on-a-chip (LoC) devices. A majority of these devices use microfluidics to manipulate precisely samples and reagents for bioanalysis. However, filling microfluidic devices with liquid can be prone to failure. For this reason, we have implemented a simple, yet efficient method for monitoring liquid displacement in microfluidic chips using capacitive sensing and a compact (75 mm × 30 mm × 10 mm), low-cost ($60), and battery-powered (10-hour autonomy) device communicating with a smartphone. We demonstrated the concept using a capillary-driven microfluidic chip comprising two equivalent flow paths, each with a total volume of 420 nL. Capacitance measurements from a pair of electrodes patterned longitudinally along the flow paths yielded 17 pL resolution in monitoring liquid displacement at a sampling rate of 1 data/s (~1 nL/min resolution in the flow rate). We characterized the system using human serum, biological buffers, and water, and implemented an algorithm to provide real-time information on flow conditions occurring in a microfluidic chip and interactive guidance to the user.
This paper presents a new tuning fork gyroscope structure with a highly linear coupling mechanism that keeps the phases of the drive mode oscillating masses exactly opposite with the help of a symmetrically anchored ring-shaped spring. This structure eliminates the risk of drive mode instability due to any lower frequency structural modes and provides very linear drive mode oscillations together with very low g-sensitivity. The gyroscope is fabricated with the SOI-MUMPS process of MEMSCAP. The fabricated gyroscope has bias instability and angle random walk of 200 deg/hr and 5.47 deg/Vhr, respectively, according to Allan Variance curve. The g-sensitivy and scale factor are measured as 9.3 (deg/hr)/g and 12 mV/(deg/sec) with an R2 nonlinearity of 0.05%.
Rapid tests for glucose-6-phosphate dehydrogenase (G6PD) are extremely important for determining G6PD deficiency, a widespread metabolic disorder which triggers hemolytic anemia in response to primaquine and tafenoquine medication, the most effective drugs for the radical cure of malaria caused by Plasmodium parasites. Current point-of-care diagnostic devices for G6PD are either qualitative, do not normalize G6PD activity to the hemoglobin concentration, or are very expensive. In this work we developed a capillary-driven microfluidic chip to perform a quantitative G6PD test and a hemoglobin measurement within 2 minutes and using less than 2 μL of sample. We used a powerful microfluidic module to integrate and resuspend locally the reagents needed for the G6PD assay and controls. We also developed a theoretical model that successfully predicts the enzymatic reactions on-chip, guides on-chip reagent spotting and allows efficient integration of multiple assays in miniaturized formats with only a few nanograms of reagents.
A review is presented of advances and challenges in fully integrated systems for personalised medicine applications. One key issue for the commercialisation of such systems is the disposability of the assay-substrate at a low cost. This work adds a new dimension to the integrated circuits technology for lab-on-a-chip systems by employing 3D integration for improved performance and functionality. It is proposed that a disposable biosensing layer can be aligned and temporarily attached to the 3D CMOS stack by the vertical interconnections, and can be replaced after each measurement.
11 January 2013 in IEEE Transactions on Components, Packaging and Manufacturing Technology
This paper presents a chip-level post-complementary metal oxide semiconductor (CMOS) processing technique for 3-D integration and through-silicon-via (TSV) fabrication. The proposed technique is based on dry-film lithography, which is a low-cost and simple alternative to spin-coated resist. Unlike conventional photolithography methods, the technique allows resist patterning on very high topography, and therefore chip-level photolithography can be done without using any wafer reconstitution approach. Moreover, this paper proposes a via sidewall passivation method which eliminates dielectric etching at the bottom of the via and simplifies the whole integration process. In this paper, two 50- μm-thick chips were post-processed, aligned, bonded, and connected by Cu TSVs, which have parylene sidewall passivation. Daisy-chain resistance measurements show 0.5- Ω resistance on average for 60- μm-diameter TSVs, with a yield of more than 99% for 1280 TSVs from five different chip stacks. Subsequently, the techniques were applied to CMOS microprocessor stacking as a test vehicle. Die-level post-CMOS processing for 40- μm-diameter via etching, redistribution layer patterning, and chip-to-chip bonding were successfully demonstrated with the real chips.