João Gomes

Dr. João Gomes

Department of Electrical Engineering, ISE, University of Algarve, 8005-139 Faro, Portugal
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

2 December 2019 in Atmosphere
Verified
Journal Article
Open access
PDF file
ECEusébio Conceição
Eusébio Conceição
João GomesJoão Gomes
João Gomes
HAHazim B. Awbi
Hazim B. Awbi
The influence of the airflow in a solar passive building on the indoor air quality and thermal comfort levels was investigated. The numerical study for a university library was conducted using a software that simulates the building thermal behavior with complex topology, in transient conditions, for evaluating the indoor air quality and occupants’ thermal comfort levels for typical summer and winter days. Solar radiation was used as a renewable energy source to increase simultaneously the thermal comfort and air quality levels and reduce building energy consumption. Regarding the solar passive building, consideration was given to all of the building structure envelope, shading devices and interior details, while in the solar active building active ventilation was used. To analyze the airflow that simultaneously provides the best indoor air quality and thermal comfort levels, a new integral methodology based on the minimization of the total number of uncomfortable hours was used. The results show that it was possible to determine an air change rate that ensures a good compromise between thermal comfort and indoor air quality. An optimal air change rate of two and three renewals per hour had been determined, respectively, for winter and summer conditions.

15 January 2019 in Inventions
Verified
Journal Article
Open access
PDF file
ECEusébio Conceição
Eusébio Conceição
ASAntónio F. M. Sousa
António F. M. Sousa
João GomesJoão Gomes
João Gomes
Antonio RuanoAntonio Ruano
Antonio Ruano
In this work, HVAC (Heating, Ventilation and Air Conditioning) systems applied in university buildings with control based on PMV (Predicted Mean Vote) and aPMV (adaptive Predicted Mean Vote) indexes are discussed. The building’s thermal behavior with complex topology, in transient thermal conditions, for summer and winter conditions is simulated by software. The university building is divided into 124 spaces, on two levels with an area of 5931 m2, and is composed of 201 transparent surfaces and 1740 opaque surfaces. There are 86 compartments equipped with HVAC systems. The simulation considers the actual occupation and ventilation cycles, the external environmental variables, the internal HVAC system and the occupants’ and building’s characteristics. In this work, a new HVAC control system, designed to simultaneously obtain better occupants’ thermal comfort levels according to category C of ISO 7730 with less energy consumption, is presented. This new HVAC system with aPMV index control is numerically implemented, and its performance is compared with the performance of the same HVAC system with the usual PMV index control. Both HVAC control systems turn on only when the PMV index or the aPMV index reaches values below −0.7, in winter conditions, and when the PMV index or the aPMV index reaches values above +0.7, in summer conditions. In accordance with the results obtained, the HVAC system guarantees negative PMV and aPMV indexes in winter conditions and positive PMV and aPMV indexes in summer conditions. The energy consumption level is higher in winter conditions than in summer conditions for compartments with shading, and it is lower in winter conditions than in summer conditions for compartments exposed to direct solar radiation. The consumption level is higher using the PMV control than with the aPMV control. Air temperature, in accordance with Portuguese standards, is higher than 20 °C in winter conditions and lower than 27 °C in summer conditions. In Mediterranean climates, the HVAC systems with aPMV control provide better occupants’ thermal comfort levels and less energy consumption than the HVAC system with PMV control.

25 October 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
ECEusébio Conceição
Eusébio Conceição
João GomesJoão Gomes
João Gomes
MCMª Inês Conceição
Mª Inês Conceição
MCMargarida Isabel Lúcio Conceição
Margarida Isabel Lúcio Conceição
MLMaria Manuela Lúcio
Maria Manuela Lúcio
HAHazim B. Awbi
Hazim B. Awbi
Air renewal rate is an important parameter for both indoor air quality and thermal comfort. However, to improve indoor thermal comfort, the air renewal rate to be used, in general, will depend on the outdoor air temperature values. This article presents the modelling of indoor air quality and thermal comfort for occupants of a passive building subject to a climate with warm conditions. The ventilation and shading strategies implemented for the interior spaces are then considered, as well as the use of an underground space for storing cooled air. The indoor air quality is evaluated using the carbon dioxide concentration, and thermal comfort is evaluated using the Predicted Mean Vote index. The geometry of the passive building, with complex topology, is generated using a numerical model. The simulation is performed by Building Thermal Response software, considering the building’s geometry and materials, ventilation, and occupancy, among others. The building studied is a circular auditorium. The auditorium is divided into four semi-circular auditoriums and a central circular space, with vertical glazed windows and horizontal shading devices on its entire outer surface. Typical summer conditions existing in a Mediterranean-type environment were considered. In this work, two cases were simulated: in Case 1, the occupation is verified in the central space and the four semi-circular auditoriums and all spaces are considered as one; in Case 2, the occupation is verified only in each semi-circular auditorium and each one works independently. For both cases, three strategies were applied: A, without shading and geothermal devices; B, with a geothermal device and without a shading device; and C, with both shading and geothermal devices. The airflow rate contributes to improving indoor air quality throughout the day and thermal comfort for occupants, especially in the morning. The geothermal and shading devices improve the thermal comfort level, mainly in the afternoon.

30 March 2023 in Inventions
Verified
Journal Article
Open access
PDF file
MCMª Inês Conceição
Mª Inês Conceição
ECEusébio Conceição
Eusébio Conceição
MLMaria Manuela Lúcio
Maria Manuela Lúcio
João GomesJoão Gomes
João Gomes
HAHazim B. Awbi
Hazim B. Awbi
The DSF (double-skin facade) system is an important element in building design and is used in adjacent spaces to control the inlet solar radiation, heat the air, reduce energy consumption, decrease the acoustics levels, and produce photovoltaic energy, among other improvements. The DSF system can, for example, be used in winter conditions to heat the air, which is then transported to non-adjacent spaces to improve the thermal comfort level and the indoor air quality that the occupants are subjected to. Smooth DSF systems, which are a focus in the literature, are subjected to higher solar radiation levels at a specific hour of the day. The semi-circular DSF system used in this work, which was built from a group of smooth DSF systems with different orientations, guarantees the reception of the highest incident solar radiation throughout the entire day. This work presents a numerical study of a new DSF system, called the semi-circular DSF. The DSF system consists of a set of 25 smooth DSFs with different orientations, each one consisting of an outer glazed surface and an inner surface provided by the outer facade of the auditorium, both separated by an air channel. In this work, the influence of the radius of the semi-circular DSF system and the opening angle of the DSF system on the thermal response of the auditorium was analysed. Thus, six auditoriums were considered: two sets of three auditoriums with radii of 5 m and 15 m, with each of the auditoriums having a different DSF opening angle (45°, 90°, and 180°). It was found that the greater the radius of the semi-circular DSF and the opening angle of the DSF system, the greater the area of its glazed surface and, consequently, the greater the availability of solar heating power. Therefore, during the occupation period, only the set of auditoriums with the largest semi-circular DSF radius managed to present acceptable levels of thermal comfort, which were verified from mid-morning until late afternoon. As for the opening angle of the DSF system, the influence was not very significant, although slight improvements in thermal comfort were noted when the value of this angle was reduced (see Case F as an example) due to the corresponding decrease in the volume of indoor air to be heated. In all auditoriums (see Case A to Case F), it was verified that the indoor air quality was acceptable for the occupants, so the airflow rate was adequately promoted by the ventilation system.

4 March 2021 in Inventions
Verified
Journal Article
Open access
PDF file
ECEusébio Conceição
Eusébio Conceição
João GomesJoão Gomes
João Gomes
MLMaria Manuela Lúcio
Maria Manuela Lúcio
HAHazim B. Awbi
Hazim B. Awbi
In this study a system constituted by seven double skin facades (DSF), three equipped with venetian blinds and four not equipped with venetian blinds, applied in a virtual chamber, is developed. The project will be carried out in winter conditions, using a numerical model, in transient conditions, and based on energy and mass balance linear integral equations. The energy balance linear integral equations are used to calculate the air temperature inside the DSF and the virtual chamber, the temperature on the venetian blind, the temperature on the inner and outer glass, and the temperature distribution in the surrounding structure of the DSF and virtual chamber. These equations consider the convection, conduction, and radiation phenomena. The heat transfer by convection is calculated by natural, forced, and mixed convection, with dimensionless coefficients. In the radiative exchanges, the incident solar radiation, the absorbed solar radiation, and the transmitted solar radiation are considered. The mass balance linear integral equations are used to calculate the water mass concentration and the contaminants mass concentration. These equations consider the convection and the diffusion phenomena. In this numerical work seven cases studies and three occupation levels are simulated. In each case the influence of the ventilation airflow and the occupation level is analyzed. The total number of thermal and indoor air quality uncomfortable hours are used to evaluate the DSF performance. In accordance with the obtained results, in general, the indoor air quality is acceptable; however, when the number of occupants in the virtual chamber increases, the Predicted Mean Vote index value increases. When the airflow rate increases the total of Uncomfortable Hours decreases and, after a certain value of the airflow rate, it increases. The airflow rate associated with the minimum value of total Uncomfortable Hours increases when the number of occupants increases. The energy production decreases when the airflow increases and the production of energy is higher in DSF with venetian blinds system than in DSF without venetian blinds system.