Hazim B. Awbi

Dr. Hazim B. Awbi

School of Built Environment, University of Reading, Reading, United Kingdom

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Building and Environment
Verified
Journal Article
Closed access
TATaha Arghand
Taha Arghand
Taghi KarimipanahTaghi Karimipanah
Taghi Karimipanah
HAHazim B. Awbi
Hazim B. Awbi
Mathias CehlinMathias Cehlin
Mathias Cehlin
ULUlf Larsson
Ulf Larsson
ELElisabet Linden
Elisabet Linden

16 November 1998 in Renewable Energy
Verified
Journal Article
Closed access
HAHazim B. Awbi
Hazim B. Awbi

22 February 2018 in Buildings
Verified
Journal Article
Open access
PDF file
ECEusébio Conceição
Eusébio Conceição
CSCristina I. M. Santiago
Cristina I. M. Santiago
MLMª. Manuela J. R. Lúcio
Mª. Manuela J. R. Lúcio
HAHazim B. Awbi
Hazim B. Awbi
This paper concerns the prediction of indoor air quality (IAQ), thermal comfort (TC) and draught risk (DR) for a virtual classroom with desk-type personalized ventilation system (PVS). This numerical study considers a coupling of the computational fluid dynamics (CFD), human thermal comfort (HTC) and building thermal behavior (BTB) numerical models. The following indexes are used: the predicted percentage of dissatisfied people (PPD) index is used for the evaluation of the TC level; the carbon dioxide (CO2) concentration in the breathing zone is used for the calculation of IAQ; and the DR level around the occupants is used for the evaluation of the discomfort due to draught. The air distribution index (ADI), based in the TC level, the IAQ level, the effectiveness for heat removal and the effectiveness for contaminant removal, is used for evaluating the performance of the personalized air distribution system. The numerical simulation is made for a virtual classroom with six desks. Each desk is equipped with one PVS with two air terminal devices located overhead and two air terminal devices located below the desktop. In one numerical simulation six occupants are used, while in another simulation twelve occupants are considered. For each numerical simulation an air supply temperature of 20 °C and 24 °C is applied. The results obtained show that the ADI value is higher for twelve persons than for six persons in the classroom and it is higher for an inlet air temperature of 20 °C than for an inlet air temperature of 24 °C. In future works, more combinations of upper and lower air terminal devices located around the body area and more combinations of occupants located in the desks will be analyzed.

12 September 2012 in Indoor and Built Environment
Verified
Journal Article
Open access
PDF file
IAI. Almesri
I. Almesri
HAHazim B. Awbi
Hazim B. Awbi
EFE. Foda
E. Foda
KSK. Sirén
K. Sirén
This study introduces a new Air Distribution Index ( ADI)New to assess the ventilation performance in uniform and nonuniform thermal environments. The index comprises parameters for assessing the indoor thermal comfort and air quality in occupied spaces. The thermal comfort assessment was carried out using a virtual thermal manikin that is adjusted by a model of human thermoregulation and coupled with a psychological comfort model. The virtual manikin was used in a computational fluid dynamics (CFD) code to simulate tests in an environmental chamber that were largely conducted under thermally neutral conditions with mixing ventilation (MV) or displacement ventilation (DV) systems. Eight human subjects were used in the study that included measurement of their skin temperature, local and overall thermal sensation votes during their exposure to the MV and DV systems. The results from CFD predictions were compared with measurements in the test chamber. The predicted ( ADI)New parameters, such as the thermal comfort, the ventilation effectiveness for both heat and contaminant removals as well as the local mean age of air, were compared with measured values in the chamber and found to be in good agreement. The results demonstrate that ( ADI)New is a useful index for evaluating the performance of a ventilation system under uniform thermal environment and can also be applied to nonuniform environment.

2 December 2019 in Atmosphere
Verified
Journal Article
Open access
PDF file
ECEusébio Conceição
Eusébio Conceição
João GomesJoão Gomes
João Gomes
HAHazim B. Awbi
Hazim B. Awbi
The influence of the airflow in a solar passive building on the indoor air quality and thermal comfort levels was investigated. The numerical study for a university library was conducted using a software that simulates the building thermal behavior with complex topology, in transient conditions, for evaluating the indoor air quality and occupants’ thermal comfort levels for typical summer and winter days. Solar radiation was used as a renewable energy source to increase simultaneously the thermal comfort and air quality levels and reduce building energy consumption. Regarding the solar passive building, consideration was given to all of the building structure envelope, shading devices and interior details, while in the solar active building active ventilation was used. To analyze the airflow that simultaneously provides the best indoor air quality and thermal comfort levels, a new integral methodology based on the minimization of the total number of uncomfortable hours was used. The results show that it was possible to determine an air change rate that ensures a good compromise between thermal comfort and indoor air quality. An optimal air change rate of two and three renewals per hour had been determined, respectively, for winter and summer conditions.

1 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
ECEusébio Conceição
Eusébio Conceição
HAHazim B. Awbi
Hazim B. Awbi
This work evaluates the integral effect of thermal comfort (TC), indoor air quality (IAQ) and Draught Risk (DR) for desks with four personalized ventilation (PV) systems. The numerical study, for winter and summer thermal conditions, considers a virtual chamber, a desk, four different PV systems, four seats and four virtual manikins. Two different PV configurations, two upper and two lower air terminal devices (ATD) with different distance between them are considered. In this study a coupling of numerical methodology, using one differential and two integral models, is used. The heating, ventilating and air conditioning (HVAC) system performance in this work is evaluated using DR and room air removal effectiveness (εDR) that is incorporated in an Air Distribution Index (ADI). This new index, named the Air Distribution Turbulence Index (ADTI), is used to consider simultaneously the TC, the IAQ, the DR and the effectiveness for heat removal (εTC), contaminant removal (εAQ) and room air removal (εDR). The results show that the ADI and ADTI, are generally higher for Case II than for Case I, increase when the inlet air velocity increases, are higher when the exit air is located at a height 1.2 m than when is located at 1.8 m, and are higher for summer conditions than for winter conditions. However, the values are higher for the ADI than ADTI.