In order to fulfill the European Energy Performance of Buildings Directive (EPBD) requirements regarding the reduction of energy consumption in buildings, great attention is paid to primary energy consumption. Wind energy is considered a type of primary energy. The analysis of the literature has revealed that wind energy is evaluated by different methods. Therefore, the aim of this article is to calculate the effect of the parameters of wind sources and wind speed on the primary energy factor of wind turbines. In order to achieve this aim, the primary energy factor of investigated 100 wind turbines and 11 wind farms operating in Lithuania was calculated. The results of the investigation show that the difference in the non-renewable primary energy factors between wind turbines with regard to their capacity is 35%. In addition, primary energy factor (PEF) values depend on geographic location and climate conditions. This paper provides a recommendation that the EU energy efficiency and renewable energy directives and regulations of all EU member states should use the same or, at least, a very similar methodology for the calculation of the primary energy factors of renewable and non-renewable energy sources.
Following a new climate and energy plan, the European Union (EU) gives big attention to energy savings. The overall assessment of energy saving measures is very important. Thus, it is crucial to estimate in a proper way the primary energy factor, which is used in calculations of primary energy consumption from renewable energy (RE) sources in a Nearly Zero Energy Building (NZEB). The conduced studies of the literature and national regulations showed that different methods to determine energy from photovoltaic (PV) systems are used. The aim of this paper is to evaluate the primary energy factors of energy from photovoltaics and determine the average value. To achieve this aim, the data of 30 photovoltaic systems from Lithuania were analyzed. The results show a 35% diversification in the values of non-renewable primary energy factor, depending on the PV systems’ capacities, with the average on a level of 1.038.
There is currently no common or standardized procedure for certification of the energy performance of buildings, as each EU Member State takes into account the specificities of its own construction sector when implementing the provisions of Directive 2010/31/EU. This usually depends on two features: the purpose of the building and the climate. Therefore, the purpose of this paper is to evaluate the influence of the hydropower primary energy factor on assessing the energy performance of buildings. For this purpose, non-renewable primary energy factor values were analyzed regarding actual energy production and consumption data from 19 Lithuanian hydroelectric plants. The results of the studies show that the average value of the non-renewable primary energy factor of hydropower plants is 0.059.
In order to fulfil the European Energy Performance of Buildings Directive (EPBD) requirements regarding the reduction of energy consumption in buildings, much attention has been paid to primary energy consumption. Wind energy is one type of primary energy. The analysis of the literature has revealed that wind energy is evaluated by different methods. Therefore, the aim of this article was to calculate the effect of the parameters of wind sources on the primary energy factor of wind turbines. In order to achieve this aim, the primary energy factor of 100 investigated wind turbines and 11 wind farms operating in Lithuania was calculated. Investigation results showed that the difference of the non-renewable primary energy factor between wind turbines due to capacity is 35%. This paper provides a recommendation with regard to EU energy efficiency and renewable energy directives and regulations: All EU member states should use the same or very similar methodology for the calculation of the primary energy factor of renewable and non-renewable energy sources.
The European Commission has set the target in the Energy Efficiency Directive (EED) to reduce EU primary energy consumption in 2020 by 20%. A crucial aspect of the overall assessment of energy saving measures that affect electricity demand is the primary energy factor that is used for evaluation of primary energy consumption from renewable energy resources in a Nearly Zero Energy Building (nZEB). The analysis of the resources has revealed that energy from photovoltaics is evaluated using different methods. Therefore, this article’s aim is to investigate and evaluate the primary energy factor of energy from photovoltaics using the data of produced and consumed energy of 30 photovoltaic (PV) systems operating in Lithuania. Investigation results show that the difference of non-renewable primary energy factor between the PV systems due to capacities is 35%. In addition, the results of the studies show that the average value of the primary energy factor of PV systems in Lithuania is 1.038.